Congratulations 

on the purchase of your ultraviolet (UV) water disinfection 

system! This system uses the most advanced UV technology on the market and is 
designed to provide you with years of trouble free operation with minimal maintenance 
required to protect your drinking water from microbiological contaminants.
To ensure ongoing disinfection of your water, UV lamps need to be replaced annually 
with VIQUA factory-supplied replacements. VIQUA lamps are the result of extensive 
development resulting in a highly efficient disinfection platform with extremely stable UV 
output over the entire 9000 hour lifetime. Its success has led to a proliferation of non-
genuine copies in the market.

The UV lamp is the heart of the disinfection system, and there should be no compromise 
when it's time for a replacement.

Why should you insist on genuine factory supplied VIQUA replacement lamps?

Use of widely available, non-genuine, replacement lamps has been shown to 
damage the control module of VIQUA UV disinfection equipment.

An increasing number of calls to VIQUA Technical Support are connected with non-
genuine lamps being used (unknowingly) as replacements. 

Damage arising from the use of non-genuine lamps poses a safety risk and is not 
covered by equipment warranty.

Unless the UV equipment is equipped with a UV sensor (monitor), it is not possible to 
verify the UV (invisible) output of replacement lamps. 

Similar appearance to the original lamp and the presence of (visible) blue light does 
not mean equivalent disinfection performance. 

VIQUA replacement lamps undergo rigorous performance testing and strict quality 
control processes to ensure that the safety and performance certifications of the 
original equipment are not compromised.

So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement 
lamps.

Содержание IHS10-D4

Страница 1: ...o Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models IHS10 D4 IHS12 D4 IHS22 D4 Owner s Manua...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...ymbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electri...

Страница 4: ...f the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey...

Страница 5: ...6 Power cord 602636 120V IHS12 D4 IHS22 D4 IHS10 D4 602637 230V IHS12 D4 2 IHS22 D4 2 IHS10 D4 2 260013 Australian IHS12 D4 2A IHS22 D4 2A IHS10 D4 2A 260012 UK IHS12 D4 2B IHS22 D4 2B IHS10 D4 2B 7 C...

Страница 6: ...hole Home System Provides filtration and disinfection of the water 6 Controller Powers and controls the UV lamp Provides human interface displaying information and allowing control inputs such as muti...

Страница 7: ...in the metal bracket 2 Slide controller onto mounting bracket 3 Insert the reference card between controller and mounting bracket 4 Connect power cord to controller DO NOT connect the power cord to t...

Страница 8: ...d any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemically disinfected to e...

Страница 9: ...ure Inspect for any leaks Maintenance 9 Section 4 Maintenance Always disconnect power before performing any work on the disinfection system Always shut off water flow and release water pressure before...

Страница 10: ...nd and turn lamp counter clockwise and pull the lamp outside the chamber in upward direction 5 1 2 Insert new lamp into the quartz sleeve and thread into sleeve bolt until hard stop 6 Connect the gree...

Страница 11: ...ving sleeve bolt 2 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Страница 12: ...cool for 10 minutes 2 Shut off the water supply Close each faucet 3 Press the pressure button to release the pressure from the cartridges 4 Remove the drain plug at the bottom of the sump and place a...

Страница 13: ...system from main power supply 2 Check for secure lamp connection 3 Restore power to UV system 4 If failure message repeats replace UV lamp Audible alarm may be silenced for 24 Hours UV Lamp Near End...

Страница 14: ...assembly hand tight Alarm Refer to Section 5 1 Refer to Section 5 1 System is operating but water tests reveal bacterial contamination Equipment downstream of UV system is acting as a breeding ground...

Страница 15: ...hr 16 gpm 60 lpm 3 6 m3 hr 16 gpm 60 lpm 3 6 m3 hr Maximum rated flow at dose of 30 mJ cm2 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr Maximum rated flow at dose of 40 mJ...

Страница 16: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...