Installation
7
Section 3
Installation
3.1 Installing UV System
Prerequisites:
•
Determine appropriate indoor location of the controller and chamber, refer to
•
Make sure that the controller is installed higher than the chamber and away from all water sources.
•
Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.
•
Make sure to turn off the main water supply.
•
Make all necessary plumbing connections refer to
Procedure:
1
•
Install the UV system on the
wall using lag bolts (not
supplied). Mounting holes are
located in the metal bracket.
2
•
Slide controller onto mounting
bracket.
3
•
Insert the reference card
between controller and
mounting bracket.
4
•
Connect power cord to
controller.
•
DO NOT connect the power
cord to the GFCI outlet at this
time.
5
•
Place O-ring on the sleeve as
shown. Insert the sleeve into
the chamber as shown in
step 6.
6
•
Ensure quartz sleeve is
properly centered in the
chamber.
7
2
1
•
Place sleeve bolt onto the
quartz sleeve, carefully push
down and hand tighten onto
chamber.
8
2
1
•
Insert lamp into the quartz
sleeve and thread into sleeve
bolt until hard stop.
C A U T I O N
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely
fastened to ground stud on UV chamber.