Vintage Air 551168 Скачать руководство пользователя страница 21

 

 

www.vintageair.com

21

901277 REV F 11/18/16, PG 21 OF 24

Symptom                 Condition                          Checks                                                   Actions    

                                             N

ot

es

Blower 

sta

ys 

on 

high 

speed 

when 

ignition 

is 

on.

1a.

No 

other 

functions 

work.

Check 

for 

damaged 

pins 

or 

wires 

in 

control 

head 

plug.

V

erif

that 

all 

pins 

are 

inserted 

into 

plug. 

Ensure 

that 

no 

pins 

are 

bent 

or 

damaged 

in 

ECU

.

Check 

for 

damaged 

ground 

wire 

(white) 

in 

control 

head 

harness.

V

erif

continuit

to 

chassis 

ground 

with 

white 

control 

head 

wire 

at 

various 

points.

Loss 

of 

ground 

on 

this 

wire 

renders 

control 

head 

inoper

able.

All 

other 

functions 

work.

Check 

for 

damaged 

blower 

switch 

or 

potentiometer 

and 

associated 

wiring.

Blower 

sta

ys 

on 

high 

speed 

when 

ignition 

is 

on 

or 

off

.

Unplug 

3-

wire 

BSC 

control 

connector 

from 

ECU

If 

blower 

shuts 

off

ECU 

is 

either 

improperly 

wired 

or 

damaged.

Be 

sure 

the 

small, 

20 

GA 

white 

ground 

wire 

is 

connected 

to 

the 

battery 

ground 

post. 

If 

it 

is, 

replace 

the 

ECU

.

Unplug 

3-

wire 

BSC 

control 

connector 

from 

ECU

If 

blower 

sta

ys 

running, 

BSC 

is 

either 

improperly 

wired 

or 

damaged.

Check 

to 

ensure 

that 

no 

BSC 

wiring 

is 

damaged 

or 

shorted 

to 

vehicle 

ground. 

The 

BSC 

oper

ates 

the 

blower 

b

ground 

side 

pulse 

width 

modulation 

switching. 

The 

positiv

wire 

to 

the 

blower 

will 

alw

ays 

be 

hot. 

If 

the 

“ground” 

side 

of 

the 

blower 

is 

shorted 

to 

chassis 

ground, 

the 

blower 

will 

run 

on 

HI.

R

eplace 

BSC 

(This 

will 

require 

remo

val 

of 

ev

apor

ator 

from 

vehicle).

No 

other 

part 

replacements 

should 

be 

necessary

.

Compressor 

will 

not 

turn 

on 

(All 

other 

functions 

work).

2.

S

ystem 

is 

not 

charged.

S

ystem 

must 

be 

charged 

for 

compressor 

to 

engage.

Charge 

system 

or 

b

ypass 

pressure 

switch.

Danger: Never bypass  safety switch with  engine running. Serious  injury can result.

S

ystem 

is 

charged.

1b.

Troubleshoot

ing Guide

Check 

for 

fault

A/C 

potentiometer 

or 

associated 

wiring 

(Not 

applicable 

to 

3-pot 

controls).

Check 

for 

disconnected 

or 

fault

thermistor

.

Check 

continuit

to 

ground 

on 

white 

control 

head 

wire. 

Check 

for 

5V 

on 

red 

control 

head 

wire.

Check 

2-pin 

connector 

at 

ECU 

housing.

To 

check 

for 

proper 

pot 

function, 

check 

voltage 

at 

white/blue 

wire. 

V

oltage 

should 

be 

between 

0V 

and 

5V

and 

will 

vary 

with 

pot 

lev

er 

position.

Disconnected 

or 

fault

thermistor 

will 

cause 

compressor 

to 

be 

disabled.

R

ed 

wire 

at 

A/C 

pot 

should 

ha

ve 

appro

ximately 

5V 

with 

ignition 

on. 

White 

wire 

will 

ha

ve 

continuit

to 

chassis 

ground. 

White/

Blue 

wire 

should 

vary 

between 

0V 

and 

5V 

when 

lev

er 

is 

mo

ved 

up 

or 

down.

3.

Compressor 

will 

not 

turn 

off 

(All 

other 

functions 

work).

Check 

for 

fault

A/C 

potentiometer 

or 

associated 

wiring.

Check 

for 

fault

A/C 

rela

y.

R

epair 

or 

replace 

pot/control 

wiring.

R

eplace 

rela

y.

See 

blower 

switch 

check 

procedure.

Содержание 551168

Страница 1: ...tered Company 1967 68 Ford Mustang Mercury Cougar without Factory Air Evaporator Kit 551168 18865 Goll St San Antonio TX 78266 Phone 210 654 7171 Fax 210 654 3113 www vintageair com 901277 REV F 11 18...

Страница 2: ...rackets Passenger Compartment Disassembly Defrost Duct and Fresh Air Cap Installation Firewall Cover Installation Evaporator Installation Vintage Air Center Louver Installation Optional Center Louver...

Страница 3: ...beginning installation open all packages and check contents of shipment Please report any shortages directly to Vintage Air within 15 days After 15 days Vintage Air will not be responsible for missing...

Страница 4: ...system This is especially important with the receiver drier Additionally when caps are removed for assembly BE CAREFUL Some components are shipped under pressure with dry nitrogen Evacuate the System...

Страница 5: ...sensitive to voltage spikes on the power leads which can cause unexpected resets strange behavior and or permanent damage Vintage Air strives to harden our products against these types of electrical n...

Страница 6: ...efer to condenser instructions Compressor and Brackets 1 Refer to separate instructions included with the bracket kit to install the compressor bracket Passenger Compartment Disassembly 1 2 3 4 5 6 7...

Страница 7: ...mounting holes Drill 3 1 8 mounting holes under the dash See Figure 3 below Apply a 1 4 bead of silicone around the mating surface of the fresh air cap as shown in Figure 3 below Secure the fresh air...

Страница 8: ...bolts flat washers and nuts and 1 10 x 1 2 sheet metal screw See Figure 4 below NOTE The firewall cover installs on the engine compartment side of the firewall Figure 4a Figure 4 10 x 1 2 Sheet Metal...

Страница 9: ...a guide mark and drill 2 3 16 holes in the cowl See Figure 5b below Using 2 14 x 3 4 sheet metal screws secure the front evaporator mounting bracket to the inner cowl See Figure 5b below Verify that...

Страница 10: ...elow Cut the OEM center vent trim using the template provided on Page 23 See Figure 7 below NOTE Remove the louver from the center louver assembly Install the louvers into the OEM center vent trim as...

Страница 11: ...ting to the 8 discharge port on the compressor Then route the straight female fitting with service port to the 8 condenser hardline coming through the radiator core support See Figure 11 Page 13 Tight...

Страница 12: ...e upper heater line coming through the firewall as shown in Figure 10 below NOTE Install the heater control valve in line with the intake manifold pressure side heater hose and secure using hose clamp...

Страница 13: ...pumps with a cast in 3 4 heater outlet a 3 4 x 5 8 reducer fitting not supplied will need to be installed in the heater hose Figure 11 Heater Hose Heater Core Water Pump Core Support Heater Hose Heate...

Страница 14: ...louver housings under the dash using OEM screws as shown in Figure 12 below Install the louvers into the driver and passenger side louver housings as shown in Figure 12 below Control Panel OEM Screws...

Страница 15: ...diator with at least a 50 50 mixture of approved antifreeze and distilled water It is the owner s responsibility to keep the freeze protection at the proper level for the climate in which the vehicle...

Страница 16: ...ing Passenger Side Defrost Duct 2 x 14 Driver Side Defrost Duct 2 x 26 Passenger Side Louver 2 x 60 Driver Side Louver 2 x 36 Driver Side Center Louver 2 x 20 Passenger Side Center Louver 2 x 20 Plug...

Страница 17: ...e Evaporator to Intake 081066 Heater Line Evaporator to Water Pump 081067 6 Hardline 081064 2 10 O rings 10 O ring 2 1 4 20 x 1 2 Hex Bolts Located on Sub Case 6 O ring 10 Hardline 081065 Press Tape E...

Страница 18: ...VUR 232002 VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Bat...

Страница 19: ...ressor Body Is Grounded Trinary Switch Connect According To Trinary Switch Wiring Diagram Install With Servo Motor Facing Down As Shown Note Flow Direction Arrow Molded Into Valve Body And Install Acc...

Страница 20: ...ture For heat operation move the temperature lever knob all the way to hot and then adjust to the desired vent temperature The blower will momentarily change speed each time you toggle between operati...

Страница 21: ...be hot If the ground side of the blower is shorted to chassis ground the blower will run on HI Replace BSC This will require removal of evaporator from vehicle No other part replacements should be ne...

Страница 22: ...ion No mode change at all Check for damaged mode switch or potentiometer and associated wiring Partial function of mode doors Typically caused by evaporator housing installed in a bind in the vehicle...

Страница 23: ...ed Line Cut Along Dotted Line Cut Out Cut Out Cut Along Line 1 7 1 6 1 9 1 6 3 9 1 6 1 7 1 6 3 9 1 6 7 NOTE Tolerances are extremely tight on the OEM center vent trim Due to printing variances measure...

Страница 24: ......

Страница 25: ......

Страница 26: ...Qty 1 1 Part No 744004 VUE 781067 Description Gen IV 4 Vent Evaporator Sub Case Accessory Kit NOTE Images may not depict actual parts and quantities Refer to packing list for actual parts and quantiti...

Отзывы: