MAINTENANCE
The appliance must not be cleaned by water jetting
Ordinary Maintenance
Ordinary maintenance can be carried out by unqualified staff provided that
the rules reported below are complied with.
• Every day check for any possible leakage.
• Every six months clean the condenser (L) blades by means of brushes and/or com-
pressed air jets.
Be careful not to bend the blades. They are sharp, therefore always
wear leather gloves.
• Every month, or as needed, sanitize or wash the cooling coils (A) through which the
beverages flow.
Wash and rinse them with plenty of water. Use special food-specific
detergents, according to the manufacturer’s instructions.
•
Every month check that the overflow tube (Q) is not clogged by ice or dirty or cra
-
shed.
•
Every month clean the vacuum device from any dust, filaments, paper which may
overheat the motors or cause malfunctions.
EXTRAORDINARY MAINTENANCE
Extraordinary maintenance must be performed by specialized personnel exclusively.
•
Clean the tank (E) every year.
To this end, drain the tank after the ice bank has totally thawed. DO NOT use sharp
objects which may pierce the tubes or the tank. Never use abrasive products. Correct
cleaning improves the chilling performance. After cleaning, fill the tank as previously de
-
scribed with clean water, without any additives, up to 2 cm from the overflow tube.
• If the power cable is damaged, have it replaced by the manufacturer, its customer
service or qualified staff in order to avoid any risks.
STORAGE DISASSEMBLY AND DISPOSAL
• If the machine remains unused for long periods, disconnect the power cable, the
electric system and the hydraulic system; drain the machine and clean it, disinfect
and wash the cooling coils. Let the cleaned parts dry out and set them in place; at
this point, store the machine in its original packaging, if available. Never leave the
machine without its original packaging.
• VINSERVICE
will not be held responsible for the disposal of packaging materials or
machine parts or products used for its operation, such as refrigerant gas, compressor
or pressurized container, condensers, etc. Therefore the Customer will be held direct-
ly responsible for the disposal of such substances, that are potentially harmful for the
environment.
The appliance must not be cleaned by water jetting
Ordinary Maintenance
Ordinary maintenance can be carried out by unqualified staff provided that
the rules reported below are complied with.
CHANGE OF TANK WATER
When the tank water needs to be changed or disposed of, following this procedure:
1. Disconnect the machine form the power line.
2.
Remove the upper cover
3. Wait for the ice bank to be thawed completely
4. Drain the tank through the drain pipe along the machine side
5.
Fill the tank up to 2 cm from the overflow pipe
6. After repositioning and reconnecting the cooling unit repeat passages 2 and 1 in the
contrary order.
TROUBLESHOOTING
ANOMALY DETECTED
POSSIBLE CAUSES
CHECKS AND POSSIBLE
SOLUTION
• The chiller does not work
and the main switch (
IG
)
warning light does not turn
up
• Power failure
• A thermal protection has
been temporary activated
• Check that the power
cable is plugged into the
socket
• Check for disconnected
wires or cables; check the
electric system of the instal-
lation site
• The machine does not
cool (the fan (
M
), the stirrer
(
F
) and the compressor (
H
)
do not work)
• The coolant circuit is le-
aking or has an insufficient
operating pressure
• Check the refrigerating
circuit pressure or any lea-
kage of coolant liquid; re-
store the correct operating
conditions
• The refrigerating unit is
working, but the stirrer (
F
)
is not working
•
Stirrer motor overheating
•
Stirrer motor breakdown
or power drop
• Check the electric system.
•
Replace the stirrer
• The machine does not
cool (the fan (
M
), and the
compressor (
H
) are not
working but the stirrer (
F
) is
working)
•
System overheating
•
Lacking or insufficient
water level in the tank
• Check the probe (
E
)
•
Replace the probe
• Fill the tank
• The machine does not
cool (the compressor (
H
) is
not working but the fan (
M
)
and the stirrer (
F
) are wor-
king)
• Power supply failure on
the compressor
• Compressor overheating
• Compressor failure
• Check the electric con-
nections and the electric sy-
stem of the appliance
•
Replace the compressor
• The compressor is wor-
king continuously and does
not stop, causing the beve-
rages to freeze
• Thermostat failure
• Probe (
G
) failure
•
Replace the faulty parts
• Contact Vinservice Custo-
mer Service.
• The machine does not
cool (the fan (
M
) is not wor-
king, but the compressor
(
H
) and the stirrer (
F
) are
working
• Power supply failure on
the fan motor
• Fan motor failure
• Check the electric con-
nections and the electric sy-
stem of the appliance
•
Replace the fan motor
• The stirrer (
F
) motor is
noisy
• Anomaly on bearings or
motor shaft supports
• Pump supports damaged
•
Replace the stirrer motor
•
Replace the pump
• The chiller works correct-
ly, but no beverages are di-
spensed
• The taps or the pipes are
dirty or clogged
• Clean or replace the clog-
ged parts
N.B. All control and maintenance operations must be
carried out after stopping the machine and discon-
necting the power cable, that is with the plug out of
the socket. All operations, excluding those reported
below, must be carried out by specialized and autho-
rized staff.