background image

This document is the pr

operty o

f VINSER

VICE and mus

t no

t be r

epr

oduc

ed or tr

ansf

err

ed t

o thir

d parties without permis

sion.

10

REV

. 17/09/19

This document is the pr

operty o

f VINSER

VICE and mus

t no

t be r

epr

oduc

ed or tr

ansf

err

ed t

o thir

d parties without permis

sion.

11

REV

. 17/09/19

LIFE 250 (HORIZONTAL) MACHINE PARTS

N

DESCRIPTION

QTY

17

COMPRESSOR

1

34

LIGHT BIPOLAR SWITCH

1

1

CILLER BASE

1

18

EVAPORATOR SPACER D.10

6

35

STEEL HANDLE

4

2

CONSOLE SIDE PANEL 

1

19

DEHYDRATOR FILTER

1

36

PIPE OUTLET MEMBRANE

6

3

TANK SIDE PANEL

1

20

FAN GRID 

2

37

HAN. FIXING STEEL PLATE

4

4

INSPECTION GRID

1

21

FAN MOTOR

2

38

OVERFLOW PIPE WASHER

1

5

COMPRESSOR GRID

1

22

REINFORCING PLATE 

1

39

SOCKET 

1

6

SERPENTINE OUTLET COVER

1

23

EVAPORATOR

1

40

WHEEL

6

7

COMPRESSOR COVER

1

24

FILTER COPPER PIPE

1

41

CONTROL SUPPORT

1

8

INSPECTION COVER

1

25

RETURN COPPER PIPE

1

42

THERMOSTAT BRACKET

1

9

DISCHARGE PIPE PROTECTION

1

26

SEND COPPER PIPE

1

43

THERMOSTAT

1

10

PYTHON PUMP

1

27

SERPENTINE KIT

1

44

THERMOSTAT PROBE SUP.

1

11

TANK

1

28

LOCKRING PLUG

1

45

OVERF. DISCHARGE PIPE

1

12

CONDENSER

1

29

COPPER CAPILLARY PIPE

1

46

OVERF. DISCHARGE NUT

1

13

POWER SUP.CABLE WIRING

1

30

 TUBO CARICA 

1

47

FAN COIL

1

14

PUMP CABLE CLIP

3

31

SERP. LOCKING FSPACER

8

48

FILTER COPPER PIPE

2

15

BOTTOM DIS. PIPE COLLAR

1

32

SERP. LOCKING M.SPACER

8

49

RETURN PIPE INSULATION

1

16

PIPE OUTLET FRAME

6

33

OVERFLOW DRAIN SEAL

1

LIFE 175 (VERTICAL) MACHINE PARTS

N

DESCRIPTION

QTY

17

PIPE OUTPUT FRAME

2

34

SERP. OUTPUT COVER

1

1

TANK BRACKET

1

18

PIPE OUTPUT MEMBRANE

2

35

METAL WASHER

1

2

TANK

1

19

BOTTOM DIS. PIPE COLLAR

2

3

COMPRESSOR SIDE PANEL

1

20

OVERFLOW DRAIN

1

4

INSPECTION PANEL

1

21

DRAIN SEAL

1

5

CONTROL SUPPORT

1

22

OVERFLOW DRAIN NUT

1

6

CILLER LIFE BASE

1

23

STEEL HANDLE

2

7

THERMOSTAT SUPPORT

1

24

HANDLE FIX STEEL PLATE

2

8

CONDENSER

1

25

EVAPORATOR SPACER D.10 

4

9

COMPRESSOR

1

26

EVAPORATOR 

1

10

COMPR. SHOCK ABOSERBER

4

27

FAN MOTOR 

1

11

FAN MOTOR

2

28

SERPENTINE KIT 

1

12

LIGHT BIPOLAR SWITCH

1

29

PROBE HOLDER TUBE

1

13

THERMOSTAT

1

30

POWER SUP. CABLE W 

1

14

OUTLET

1

31

COPPER CAPILLARY PIPE

1

15

PUMP CABLE CLIP

2

32

SEND COPPER PIPE

4

16

PYTHON PUMP

1

33

SERPENTINE KIT SPACER

4

Description

Description

33

45

23

20

21

47

12

11

37

48

7

8 6 10

16
36

14

30 28 25 29

17

18

44 32

31

27

35

3

15

46

9

38

40

1

22

19

5

43

41

39

13

2

34 42

24

26 4

1

2

3

5

4

4

6

7

8

9

10

11

12

13

14

18

17

15

16

19

20

23

24

25

26

28

29

30

31

32

33

34

35

22

21

Содержание LIFE 100

Страница 1: ...arties without permission I REV 17 09 19 OPERATION AND MAINTENANCE BOOK DOCUMENT CODE 0150LIFEENG 000 VINSERVICE s r l Via G Falcone 26 34 24050 ZANICA BG Italy Phone 39 035 672361 Fax 39 035 672699 w...

Страница 2: ...which personnel must exert extreme caution due to general hazard or dangerous voltage Zones subject to low or high temperature Possible presence of condensate or leaks which can cause slip ping or in...

Страница 3: ...ripping or humidity 3 The condenser and the ventilation grilles are completely free We recommend to re spect a distance of minimum 30 40 cm around all vents and walls in order to ensure suitable air c...

Страница 4: ...s while lifting it and make sure that special lifting belts have been placed in a central position The overlapping of machines is allowed only if the packaging is perfectly dry and in tact The machine...

Страница 5: ...f this equipment or parts of it for purposes other than those intended for usa ge is absolutely forbidden For instance Do not dry or warm clothes on the condenser grille H It is dangerous and it might...

Страница 6: ...ety viewpoint on the work environment Vinservice declines all re sponsibilities for damage of any kind deriving from improper use of the appliance or anyway unconformable with the manufacturer s instr...

Страница 7: ...e between 1 and 6 according to the temperature of the installation environment The lower position 1 is recom mended for very low temperatures of the installation site 3 4 C the following positions are...

Страница 8: ...ing Lack or insufficient water level in the tank Check the probe E Replace the probe Fill the tank The machine does not cool the compressor H is not working but the fan M and the stirrer F are wor kin...

Страница 9: ...Identification of machine and manufacturer The EC plate is to affixed in the position shown by the following figure The plates bearing the manufacturer s name are affixed on the machine side they mus...

Страница 10: ...5 PUMP CABLE CLIP 2 32 SERP LOCKING SPACER F 4 49 SERPENTINE KIT 1 16 PYTHON PUMP 1 33 SERP LOCKING SPACER M 4 LIFE 65 115 145 HORIZONTAL MACHINE PARTS N DESCRIPTION QTY 17 POWER S CABLE WIRING 1 34 F...

Страница 11: ...F DISCHARGE NUT 1 13 POWER SUP CABLE WIRING 1 30 TUBO CARICA 1 47 FAN COIL 1 14 PUMP CABLE CLIP 3 31 SERP LOCKING FSPACER 8 48 FILTER COPPER PIPE 2 15 BOTTOM DIS PIPE COLLAR 1 32 SERP LOCKING M SPACER...

Страница 12: ...taff provided that the rules reported below are complied with CHANGE OF TANK WATER When the tank water needs to be changed or disposed of following this procedure 1 Disconnect the machine form the pow...

Страница 13: ...without permission 14 REV 17 09 19 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without permission 15 REV 17 09 19 TECHNICAL DRAWINGS LIFE 50...

Страница 14: ...7 09 19 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without permission 17 REV 17 09 19 TECHNICAL DRAWINGS LIFE 100 TECHNICAL DRAWINGS LIFE 11...

Страница 15: ...out permission 18 REV 17 09 19 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without permission 19 REV 17 09 19 TECHNICAL DRAWINGS LIFE 130 TEC...

Страница 16: ...third parties without permission 20 REV 17 09 19 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties without permission 21 REV 17 09 19 TECHNICAL DR...

Страница 17: ...MOSTAT 4 PROBE 5 TANK 6 AGITATOR 7 AGITATOR SOCKET 8 AGITATOR PLUG 9 COMPRESSOR CONNECTIONS 10 COMPRESSOR PROTECTION 11 COMPRESSOR RELAY 12 STARTING CAPACITOR 13 FAN MOTOR 14 FAN MOTOR CONNECTIONS NOT...

Страница 18: ...and must not be reproduced or transferred to third parties without permission 24 REV 17 09 19 This document is the property of VINSERVICE and must not be reproduced or transferred to third parties wit...

Страница 19: ...ORMITY ACCORDING TO MACHINE DIRECTIVES EN 60335 1 EN 60335 2 24 EN 60335 2 75 2014 35 UE 2014 30 UE 2006 42 CE VINSERVICE S R L VIA G FALCONE 26 34 24050 ZANICA BG Declares under their own responsibil...