background image

Customer Service - 1.800.343.9463

Page 12

PDT JR. OPERATING INSTRUCTIONS

Operating instructions for the Vinothèque PDT Jr. Thermostat for the QT Series cabinets:

Indicators

There are three colored lights on the left side of the thermostat:

— 

PWR (Green)

: The unit is powered.

— 

RUN (Yellow)

: The compressor is running. If the light is flashing, the unit is in the five-minute lockout.

— 

SET (Red)

: This  light  flashes  when  the  set  point  temperature  is  changed  by  pressing  one  of  the  three 

control buttons. It flashes 

once

 for each press of the Up or Down button and 

twice

 when the 55 button is 

pressed.

When the unit is first turned on, all three lights flash slowly while the thermostat starts up. Once the unit  

completes its start-up check, the compressor is locked out for five minutes. During this time, the 

RUN

 light 

will flash slowly.

All three lights will flash rapidly if there is no probe connected to the thermostat.

Buttons

To change the set point temperature, press either the Up or Down button. The SET light will flash once for each 

1°F difference. This set point will remain in memory until you change it.

If you forget where the unit is set, pressing the 55 button will reset the set point to 55°F and the set light will 

flash twice. The temperature cannot be adjusted below 50°F or above 76°F. Attempting to set the unit outside 

of this range will cause the 

SET

 light to rapidly flash.

Operation

Whenever the compressor shuts off normally, a five-minute lockout period begins and the 

RUN

 light will flash 

slowly.

If the compressor runs for 90 continuous minutes, a five-minute defrost cycle is forced, during which time the 

compressor will not run. During this defrost cycle, the 

RUN

 light will flash rapidly.

Содержание Advanced GCM-01 030110

Страница 1: ...WINE CABINET OWNER S MANUAL FOR CABINETS EQUIPPED WITH WhisperKOOL 2500 WhisperKOOL 1500 WhisperKOOL 1200 Advanced QT...

Страница 2: ...ole or in part without the written consent of Vinoth que Wine Cellars Every effort has been made to ensure that the information in this manual is accurate Vinoth que Wine Cellars is not responsible fo...

Страница 3: ...d QT WhisperKOOL 1200 pg 11 Testing the Refrigeration Unit pg 14 Loading Bottles Cool Down Period pg 14 Normal Operation Maintenance pg 15 Troubleshooting pg 16 Cooling Unit Repairs pg 19 Testing a Re...

Страница 4: ...ttle again can cause damage to the compressor and negatively affect cooling A dedicated 20 amp circuit is highly recommended for optimum operation Tripped breakers and deficient performance if other d...

Страница 5: ...of the damage on the shipping document This document will then be used to file a freight claim Immediately notify Vinoth que or your distributor to file a claim You can accept or deny the delivery if...

Страница 6: ...st cooling units available for cabi nets they do produce a nominal amount of noise It is comparable to the noise a refrigerator emits during normal operation though the cooling unit may operate more o...

Страница 7: ...adjusted at our factory but they may need to be tweaked to fit your specific install location To level the unit slowly adjust the legs using the wrench Work in a clockwise motion to lengthen the leg o...

Страница 8: ...nzas If adjustments are necessary compensate for this problem by adjusting the two front and or outside legs The high side of the cabinet should be adjusted down while the low side should be adjusted...

Страница 9: ...rouble free use However we still recommend that you install a surge protector specifically for the unit Fahrenheit and Celsius readouts The thermostat has the ability to produce the readout in both Fa...

Страница 10: ...essor and the condenser fan will turn off but the in cabinet evaporator fan will continue to run for about 1 minute This is a feature of the WhisperKOOL Humidity Management WHM system The WHM is an ad...

Страница 11: ...ing from the current time and temperature forward Temperatures displayed would reflect bottle probe temperatures from that point in time and beyond 3 The Hi Low feature should be reset at initial star...

Страница 12: ...nu CPSM To access the CPSM press the Set and Down buttons simultaneously for 5 7 seconds This will display CF now press the Set and Down buttons simultaneously for another 5 7 sec onds The display wil...

Страница 13: ...tle probe tempera ture During a Probe 1 failure alarm the bottle probe temperature can be monitored by pressing the Up or Down arrow to view the temperature history HES Differential for Energy Reducti...

Страница 14: ...unit will not accumulate excessive water Therefore save electricity by switching the condensate evaporator to the Off position Temperature equalizer The temperature equalizer switch controls the fan w...

Страница 15: ...ut for five minutes During this time the RUN light will flash slowly All three lights will flash rapidly if there is no probe connected to the thermostat Buttons To change the set point temperature pr...

Страница 16: ...it and the temperature you see displayed is what the probe is reading 2 LED screen Displays your thermostat readings 3 Wine temperature reading The temperature that the bottle probe is registering to...

Страница 17: ...nose the problem and promptly resolve it LOADING BOTTLES COOL DOWN PERIOD Loading bottles The cabinet may settle slightly based on the weight of all the bottles It is best to spread the loading of bot...

Страница 18: ...evaporate excess condensation In environments of low humidity leave the switch in the Off position Temperature equalizer Turn on whenever a temperature difference is noted between the top and bottom...

Страница 19: ...ure Adjust the temperature in the room Units are designed to cool 30 F below room temperature Inadequate ventilation Assure proper space above behind and on the side of the unit Do not set anything on...

Страница 20: ...ur fingers to pull the gasket outward Doing this for several minutes will loosen the gasket material and increase its flexibility Close the door and determine if the magnetic strip within the gasket w...

Страница 21: ...ame unit built in the dry summer weather and installed in Florida will develop a convex warp as the exposed panel absorbs outside moisture How to correct a warped door Leave the door open to expose bo...

Страница 22: ...binet by unscrewing the mounting screws located on the top and rear of the cabinet 4 Loosen the seals by sliding a screwdriver between the cabinets and cooling unit housing then remove the cooling uni...

Страница 23: ...ly clean unit inside and out Vacuum charge and test the system Unit includes new thermostat If you have any further questions please contact Customer Service This warranty does not cover cosmetic dama...

Страница 24: ...hin 90 days of the date of sale the limitation on how long an implied warranty lasts does not apply to you This warranty gives you specific legal rights and you may have other rights which vary from s...

Страница 25: ...Items not covered under warranty Removal and installation of cooling unit into the cabinet Unauthorized repairs made on the unit Damage resulting from shipping Inadequate ventilation on the exhaust si...

Страница 26: ...9463 In case repair is needed for refrigeration QT Series Contact Customer Service for refrigeration technician referrals in your area WhisperKOOL Series Either follow the directions for the QT Series...

Страница 27: ...Vinoth que Wine Cellars 1738 E Alpine Ave Stockton CA 95205 800 393 9463 www vinotheque com...

Отзывы: