Page 7
GCM-01 050410
SYSTEM OPERATION (WHISPERKOOL 2500 & 1500)
This section applies to cabinets equipped with the WhisperKOOL 1500 cooling system. If your cabinet is
equipped with a PDT or PDT Jr. thermostat, please refer to the next sections.
Initial start-up
When the unit is first turned on, the control will briefly display all symbols, and the green snowflake symbol
will show up if the unit is calling for cooling. There may be a brief delay prior to the evaporator fan turning on,
as it will not start until the probe temperature drops to below 70°F. When the fan is activated, the fan symbol
will be displayed. The Advance Product Safety Technology (APST), which ensures that in the possible event of
a cooling deficiency, the heat from the in-cabinet fan will not raise the temperature of the wine cellar, which
could otherwise have an adverse effect on the wine aging process.
Normal system cycle
After the bottle probe has reached the set point (all units are shipped with the set point of 55°F and a
differential of 1 degree), the compressor and the condenser fan will turn off, but the in-cabinet evaporator
fan will continue to run for about 1 minute (This is a feature of the WhisperKOOL Humidity Management
(WHM) system). The WHM is an adjustable feature that allows the customer the convenience of managing the
humidity enhancement of their wine cellar. It is one of the many customer preference selection features that
allow the customer the ability to fine-tune the controls.
Anti-Frost Cycle
The Anti-Frost Cycle is a precautionary measure, as icing or frosting of the coil does not occur during normal
operation. The system will go through a defrost cycle every 4 hours. During the defrost cycle, the in-cabinet
fan will provide airflow across the coil, which will evaporate any frost accumulation.
Bottle probe failure protection
Should a bottle probe fail, the Advance Product Safety Technology (APST) will automatically transition the
refrigeration compressor cycles to a pre-determined time series (based on laboratory testing), which will
ensure that the temperature is kept within the safe range.
Control panel
The control panel is designed to give the user the ability to monitor and change cellar conditions when the
evaporating unit is placed in a remote location.