Vinotheque Advanced GCM-01 030110 Скачать руководство пользователя страница 22

Page 19

GCM-01 050410

COOLING UNIT REPAIRS

If repairs are needed to the cooling unit, it 

must be returned to the factory

 for evaluation and repair.

1.  Contact  our  customer  service  department  — 

(800)  343-9463

  —  and  describe  the  problems  you  are 

experiencing with the unit. The customer service department will first seek to determine that no external  

factors are contributing to the improper operation of your cooling unit.

2.  Once it is determined that the unit is operating incorrectly, the customer service department will issue 

an RMA (return merchandise authorization) number. This number must be included on the package of the 

returned cooling unit.

3.  Remove the cooling unit from the cabinet by unscrewing the mounting screws located on the top and rear 

of the cabinet.

4.  Loosen the seals by sliding a screwdriver between the cabinets and cooling unit housing, then remove the 

cooling unit.

5.  The cooling unit should then be bubble-wrapped and insulated for the shipment back to the factory.

6.  Once the cooling unit arrives at the factory, it will be  tested in a controlled environment.  An evaluation will be 

done and a customer service representative will call you with the corresponding information. The turnaround time is  

usually about 3 to 5 business days.

7.  If the unit is repaired under warranty, the factory will pay for shipping the unit back to the customer and in 

addition will reimburse the customer for the initial shipping charges (shipping ground charges).

8.  If the unit is determined to be working correctly,

 the customer

 will be responsible for paying the freight 

to have the unit returned.

Содержание Advanced GCM-01 030110

Страница 1: ...WINE CABINET OWNER S MANUAL FOR CABINETS EQUIPPED WITH WhisperKOOL 2500 WhisperKOOL 1500 WhisperKOOL 1200 Advanced QT...

Страница 2: ...ole or in part without the written consent of Vinoth que Wine Cellars Every effort has been made to ensure that the information in this manual is accurate Vinoth que Wine Cellars is not responsible fo...

Страница 3: ...d QT WhisperKOOL 1200 pg 11 Testing the Refrigeration Unit pg 14 Loading Bottles Cool Down Period pg 14 Normal Operation Maintenance pg 15 Troubleshooting pg 16 Cooling Unit Repairs pg 19 Testing a Re...

Страница 4: ...ttle again can cause damage to the compressor and negatively affect cooling A dedicated 20 amp circuit is highly recommended for optimum operation Tripped breakers and deficient performance if other d...

Страница 5: ...of the damage on the shipping document This document will then be used to file a freight claim Immediately notify Vinoth que or your distributor to file a claim You can accept or deny the delivery if...

Страница 6: ...st cooling units available for cabi nets they do produce a nominal amount of noise It is comparable to the noise a refrigerator emits during normal operation though the cooling unit may operate more o...

Страница 7: ...adjusted at our factory but they may need to be tweaked to fit your specific install location To level the unit slowly adjust the legs using the wrench Work in a clockwise motion to lengthen the leg o...

Страница 8: ...nzas If adjustments are necessary compensate for this problem by adjusting the two front and or outside legs The high side of the cabinet should be adjusted down while the low side should be adjusted...

Страница 9: ...rouble free use However we still recommend that you install a surge protector specifically for the unit Fahrenheit and Celsius readouts The thermostat has the ability to produce the readout in both Fa...

Страница 10: ...essor and the condenser fan will turn off but the in cabinet evaporator fan will continue to run for about 1 minute This is a feature of the WhisperKOOL Humidity Management WHM system The WHM is an ad...

Страница 11: ...ing from the current time and temperature forward Temperatures displayed would reflect bottle probe temperatures from that point in time and beyond 3 The Hi Low feature should be reset at initial star...

Страница 12: ...nu CPSM To access the CPSM press the Set and Down buttons simultaneously for 5 7 seconds This will display CF now press the Set and Down buttons simultaneously for another 5 7 sec onds The display wil...

Страница 13: ...tle probe tempera ture During a Probe 1 failure alarm the bottle probe temperature can be monitored by pressing the Up or Down arrow to view the temperature history HES Differential for Energy Reducti...

Страница 14: ...unit will not accumulate excessive water Therefore save electricity by switching the condensate evaporator to the Off position Temperature equalizer The temperature equalizer switch controls the fan w...

Страница 15: ...ut for five minutes During this time the RUN light will flash slowly All three lights will flash rapidly if there is no probe connected to the thermostat Buttons To change the set point temperature pr...

Страница 16: ...it and the temperature you see displayed is what the probe is reading 2 LED screen Displays your thermostat readings 3 Wine temperature reading The temperature that the bottle probe is registering to...

Страница 17: ...nose the problem and promptly resolve it LOADING BOTTLES COOL DOWN PERIOD Loading bottles The cabinet may settle slightly based on the weight of all the bottles It is best to spread the loading of bot...

Страница 18: ...evaporate excess condensation In environments of low humidity leave the switch in the Off position Temperature equalizer Turn on whenever a temperature difference is noted between the top and bottom...

Страница 19: ...ure Adjust the temperature in the room Units are designed to cool 30 F below room temperature Inadequate ventilation Assure proper space above behind and on the side of the unit Do not set anything on...

Страница 20: ...ur fingers to pull the gasket outward Doing this for several minutes will loosen the gasket material and increase its flexibility Close the door and determine if the magnetic strip within the gasket w...

Страница 21: ...ame unit built in the dry summer weather and installed in Florida will develop a convex warp as the exposed panel absorbs outside moisture How to correct a warped door Leave the door open to expose bo...

Страница 22: ...binet by unscrewing the mounting screws located on the top and rear of the cabinet 4 Loosen the seals by sliding a screwdriver between the cabinets and cooling unit housing then remove the cooling uni...

Страница 23: ...ly clean unit inside and out Vacuum charge and test the system Unit includes new thermostat If you have any further questions please contact Customer Service This warranty does not cover cosmetic dama...

Страница 24: ...hin 90 days of the date of sale the limitation on how long an implied warranty lasts does not apply to you This warranty gives you specific legal rights and you may have other rights which vary from s...

Страница 25: ...Items not covered under warranty Removal and installation of cooling unit into the cabinet Unauthorized repairs made on the unit Damage resulting from shipping Inadequate ventilation on the exhaust si...

Страница 26: ...9463 In case repair is needed for refrigeration QT Series Contact Customer Service for refrigeration technician referrals in your area WhisperKOOL Series Either follow the directions for the QT Series...

Страница 27: ...Vinoth que Wine Cellars 1738 E Alpine Ave Stockton CA 95205 800 393 9463 www vinotheque com...