![Vinotemp Wine-Mate WM-4510HZD Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/vinotemp/wine-mate-wm-4510hzd/wine-mate-wm-4510hzd_installation-use-and-care-manual_1028372025.webp)
- 24 -
Care Guide
1. Cleaning Condenser
•
Clean the condenser and air filter regularly. Condenser and filter may need to
be cleaned at least every 6 months.
•
Condenser and air filter are located on the ambient air intake side of the
cooling unit.
•
Use a condenser brush or a vacuum cleaner with an extended attachment to
clean the condenser.
•
Air filter is washable and reusable.
2. Removing Condensate
Remove the excessive condensate if it is accumulated on the cooling unit in high
humidity conditions.
3. Removing Unit
When you remove the cooling unit, beware water may come out of the unit.
4. Installing Drain Line
The unit is equipped with
an additional drain fitting.
In case of extreme
humidity there is a drain
line needed, remove the
drain plug on the bottom
left at the rear, then
remove the connection
plug and fit a 0.375” OD
drain tube into the drain
connection. Install the
cooling unit with the front
higher than the rear.
Содержание Wine-Mate WM-4510HZD
Страница 24: ...23 Fig 4 15 Cold air supply cellar air return and hot air exhaust ducts...
Страница 29: ...28 Electrical Wiring Diagrams Fig 7 1 WM 4510 8510HZD standard wiring diagram...
Страница 30: ...29 Fig 7 2 WM 4510 8510HZD crankcase heater wiring diagram...
Страница 31: ...30 Fig 7 3 WM 4510 8510HZD alarm call wiring diagram...
Страница 32: ...31 Fig 7 4 WM 4510 8510HZD cellar heater wiring diagram...
Страница 33: ...32 Fig 7 5 WM 4510 8510HZD crankcase heater alarm call wiring diagram...
Страница 34: ...33 Fig 7 6 WM 4510 8510HZD crankcase heater cellar heater wiring diagram...
Страница 35: ...34 Fig 7 7 WM 4510 8510HZD alarm call cellar heater wiring diagram...
Страница 36: ...35 Fig 7 8 WM 4510 8510HZD crankcase heater alarm call cellar heater wiring diagram...