- 5 -
CAUTION
If the condensing unit will operate below 50°F, install a low
ambient condition kit.
NOTE
The cooling capacity is determined under 55
°
F cellar
temperature, 75
°
F cellar ambient temperature and 90
°
F
condensing unit ambient temperature, with R13 interior and
R19 exterior insulations. Higher ambient temperatures or
lower insulations will cause reducing capacity and the cellar
temperature may not be maintained at 55
°
F.
The specifications are listed as follows:
Model No.
Capacity (Btu/h) / Airflow (CFM)
Max Cellar Size (cu ft)
WM-2500SSH
WM-2500SSH-LA
2500 / 220
250
WM-4500SSH
WM-4500SSH-LA
4500 / 380
1000
WM-6500SSH
WM-6500SSH-LA
6500 / 490
1500
WM-8500SSH
WM-8500SSH-LA
8500 / 750
2000
WM-12000SSH
WM-12000SSH-LA
12000 / 810
3300
NOTE
“LA” refers the unit equipped with a low ambient kit.
For further info, see Fig. 3~7.