Flow to Patient
(L/min)
Flow-
meter
(L/min)
O2%
4
6
8
10
15
20
25
30
35
40
45
50
55
60
If oxygen supply has not been turned
off and oxygen concentration is higher
than 25%, a window will appear. User
must discontinue oxygen supply before
stopping the device from running.
Warning
Continuous oxygen concentration monitoring is recommended for patients who require
increased oxygen concentration to ensure that the correct oxygen supply is provided
and suitable blood oxygen saturations are achieved as prescribed.
This device is designed with a connector for pure oxygen. Use of any other gas or
mixture of gases will prevent the device from functioning correctly.
. Keep device away from sources of ignition and/or open flames. Do not smoke near the
device.
. Oxygen concentration and flow of delivered gas should only be determined by a
physician or trained medical professional.
. Oxygen supply shall be standard dry and clean compressed oxygen for medical
applications.
. Shut off the oxygen supply before turning off the device.
. Before turning on the oxygen supply, run the device to ensure target flow rate can be
reached. Only turn on the oxygen supply when the device is running.
• Oxygen leakage may cause serious accidents.
. If an oxygen leak is discovered, shut off the supply of oxygen and contact authorized
personnel for repair. Inspect the oxygen tube and ensure it is free of folds or kinks.
8) Adjusting oxygen concentration levels
Connect the oxygen tube between the flowmeter (connected to oxygen supply) and
the oxygen inlet port at the right side of the unit. Push the oxygen tube firmly into
this port to ensure a secure connection.
Adjust the oxygen flow while monitoring the oxygen concentration shown on
the screen. Refer to the table next page to achieve the target O2%.
* The flowmeter shall be
capable of delivering oxygen
flow up to 60LPM, otherwise
the oxygen concentration
under high flow setting would
be limited to low levels.
95
18
L/
Run time 00 00 00 15
D H M S
STERILE
WATER
95
18
L/
Run time 00 00 00 15
D H M S
Ensure oxygen is
not flowing
FiO2:
54%
OK
Attention:
When oxygen supply is not connected to the device, please keep the cap of
the oxygen inlet port closed.