18
Trimmer
Function
TR1
DELAY
Adjusts the variable pause time (min 1 sec. - max 120 sec.)
as shown in the figure
TR2
WORK
Adjusts the working time (min 1 sec. - max 60 sec.) as shown in the figure
Note:
the automation must have internal limit switches
Set the working time a few seconds longer than the effective duration
of the opening and closing manoeuvre
8. Trimmer functions:
9. LED warnings and courtesy light:
LED indications:
LED
LED status
Signal description
DL1
Fixed light RED
OPEN contact (terminal 9) closed
Off
OPEN contact (terminal 9) open
DL2
Fixed light RED
CLOSE contact (terminal 10) closed
Off
CLOSE contact (terminal 10) open
DL3
Fixed light GREEN
STOP contact (terminal 11) closed
Off
CLOSE contact (terminal 11) open
DL4
Fixed light RED
START contact (terminal 13) closed
Off
START contact (terminal 13) open
DL5
Fixed light GREEN
Closing safety device SAF1 contact (terminal 14) closed
Off
Closing safety device SAF1 contact (terminal 14) open
DL6
Fixed light GREEN
Opening safety device SAF2 contact (terminal 15) closed
Off
Opening safety device SAF2 contact (terminal 15) open
DL7
Flashes RED
Control input (OPEN, CLOSE, START, remote control) or safety device
(SAF1, SAF2) occupied
Flashes RED-GREEN
Safety test failure or motor relay fault
Short flashing
RED-GREEN (< 0.2 sec)
Learning new Dip-switch settings
Fixed light RED-GREEN
Installation check mode enabled (see para. 9)
Courtesy light signalling (if connected):
Courtesy light signals
Signal description
2 flashes at the start of each manoeuvre
Safety test failure on opening or closing
4 flashes at the start of each manoeuvre
Motor relay fault
4 flashes at the end of each manoeuvre
Motor common and flashing light relay fault
10 - Installation check methods
The installation check mode is used to assign the following functions to buttons P1 and P2:
- P1 opening in man present mode
- P2 closing in man present mode
To enable the installation check mode:
- press and hold down buttons P1 and P2 for more than 3 sec.
To exit the installation check mode:
- briefly press P1 and P2 together
EN