17
Terminal no.
Terminal markings
Description
21-22
Antenna input:
21 - signal
22 - screen
6. Antenna connection (fig. 5):
7. Dip-switch functions:
No.
Position Function
DIP1
OFF
Automatic closing off
ON
Automatic closing on
DIP2
OFF
Pre-flashing off
ON
Pre-flashing on (when a command is received, the flashing light flashes for 3 seconds before the
electric motor starts)
DIP3
OFF
Automatic operation
DIP4
OFF
Operation of the START input (terminal 13) and
remote control with
2
step logic:
open-close-open
ON
Operation of the START input (terminal 13) and
remote control with
4
step logic:
open-stop-close-stop
DIP3
ON
"Dead-man” or “semi-
dead-man” operation
.
DIP4
OFF
"Dead-man” operation:
Opening:
control held down, releasing the button
will stop the automation
Closing
: control held down, releasing the button
will stop the automation
Note:
remote control and START input (terminal
13) are disabled
ON
"Semi-dead-man” operation:
Opening:
pulse control, the START input (termi-
nal 13) works according to the open-stop-open-
stop logic (also remote control)
Closing
: control held down, releasing the close
button will stop the automation
Note:
activating this mode will disable the auto
closing function
DIP 5
OFF
Collective function off
ON
Collective function on:
During opening, the START input (terminal 13) and the remote control are ignored
During the pause time the START input (terminal 13) and the remote control reset the pause.
DIP6
OFF
Safety device input test on closing SAF1 (terminal 14) off
ON
Safety device input test on closing SAF1 (terminal 14) on
DIP7
OFF
Safety device input test on opening SAF2 (terminal 15) off
ON
Safety device input test on opening SAF2 (terminal 15) on
DIP8
OFF
Safety device input on closing SAF1 (terminal 14) and in opening SAF2 (terminal 15) with NC contact
Note:
both inputs are with NC contact
ON
Safety device input on closing SAF1 (terminal 14) and in opening SAF2 (terminal 15) balanced with
8.2 KΩ resistance
Note:
both inputs are balanced
Learning of new Dip-Switch settings without restarting the control unit:
- Press and hold down buttons P1 and P2 for less than 1 sec.
- Release buttons P1 and P2
- The control unit signals the reading of the Dip-switch settings by LED DL7 flashing RED-GREEN for 0.2 sec
EN