background image

Viale Vicenza, 14

36063 Marostica VI - Italy

www.vimar.com

90720449A0  05  1606

Eikon

20449

Plana

14449

SETTINGS.

Used for setting the “

Clock

”, “

Date

”, “

Alarm Sound

”, 

Display

”, “

Language

”, “

Mode

”.

• 

Clock

: set the current time (hours and minutes).

• 

Date

: set the current date (date, month, year).

• 

Alarm Sound

: set the alarm tone, from a choice of three 

possible alarm sounds.

• Display

: adjust the contrast of the display.

• 

Language

: cselect the language in which the instructions 

are displayed, choosing between Italiano, English, Français, 
Español and Deutsch.

• 

Mode

: select the principal display mode, choosing 

between:

  - current date and time.
  - temperature, current date and time.

INSTALLATION RULES.

The installation must be done according to rules for electrical 
installations of buildings in force in the country where the pro-
ducts are installed.

Before the power supply must be installed in an easily 
accessible bipolar type switch with contact separation of 
at least 3 mm.

CONFORMITY TO STANDARDS

LV Directive
Standard EN 60065
EMC Directive
Standards EN 61000-6-1, EN 61000-6-3

DESCRIPTION.

Switch with integrated calendar and thermometer, suitable 
for installation near a headboard in a normal flush mounting, 
surface mounting or table mounting boxes.

CHARACTERISTICS.

• Supply voltage: 120-230 V~ ±10% 50-60 Hz
• Absorption: 1,5 W
• Front controls: “

Esc

”, “

”, “

”, “

ok

”/”

set

• CLOCK function
• ALARM function with choice of 3 alarm sounds.
• THERMOMETER function with indication in °C.
•  Clock backup battery duration: about 20 days, with recharge-

able lithium buffer battery

• Timed back-lit display, activated by pressing one of the four 

buttons.

• Multilingual menu: Italian, English, French, Spanish and 

German.

• Protection degree: IP40
• Class II equipment: 
• Operating temperature: 0 °C +40 °C
• Ambient temperature range during transport: -25 °C +60 °C
• Clock accuracy: ≤ ± 2 s per day.

OPERATION.

To set the electronic alarm clock, from the starting screen of 
the display:
• Press any one of the front buttons.
•  The "

Alarm Set

" menu item appears, and the following icons 

are displayed:
- “

Esc

” (button 

A

): return to the preceding screen.

- “

” (button 

B

): scroll down the settings or menus.

- “

” (button 

C

): scroll up the settings or menus.

- “

ok

” (button 

D

): proceed to the next screen.

- “

set

” (button 

D

): confirm the entered value. 

• Press “

” (button 

B

) to invoke the “

Settings

” menu item.

SET ALARM.

Used for setting “

Alarm ON

” or “

Alarm OFF

”.

• 

Alarm ON

: turn on the alarm and program the alarm time.

• 

Alarm OFF

: turn off the alarm.

Electronic alarm clock, supply voltage 120-230 V~ 50-60 Hz - 2 modules.

Alarm on/off status

and alarm time

Ambient

temperature

Current date

Current

time

A

Eikon

Plana

B

C D

Alarm on/off status

and alarm time

Ambient

temperature

Current date

A B

C D

Current

time

Items of the

scrolling menu

ESC (button A).

Return to the

preceding screen.

(button B).

Downward scrolling

of settings or menus.

OK (button D).

Confirm the

entered value 

or proceed to

the next screen.

     

(button C).

Upward scrolling

of settings and menus.

Front view and view of controls.

L

N

Electrical diagram.

Содержание Eikon 20449

Страница 1: ...mbres disponibles Función TERMÓMETRO con la indicación de la temperatura en C Reserva de carga para el reloj cerca de 20 días con batería tampón al litio recargable Display con iluminación temporizada que se acciona pulsan do uno de los cuatro botones Menú plurilingüe italiano inglés francés español y alemán Grado de protección IP40 Artefacto de clase II Temperatura de funcionamiento 0 C 40 C Temp...

Страница 2: ...α πάνω στις ρυθμίσεις και στα μενού ok μπουτόν D επιτρέπει τη μετάβαση στην επόμενη οθόνη set μπουτόν D επιτρέπει την επιβεβαίωση του προγραμματισμένου δεδομένου Πιέστε μπουτόν B για να εμφανίσετε το στοιχείο του μενού Settings ΡΥΘΜΙΣΗ ΞΥΠΝΗΤΗΡΙΟΥ Επιτρέπει τις ρυθμίσεις Alarm ON ή Alarm OFF Alarm ON επιτρέπει τον προγραμματισμό της ώρας και την ενεργοποίηση του ξυπνητηριού Alarm OFF επιτρέπει την...

Страница 3: ...asto D Consente di confermare un dato impostato o di passare alla videata successiva tasto B Consente di scorrere verso il basso impostazioni e menù tasto C Consente di scorrere verso l alto impostazioni e menù Vista frontale comandi e display DESCRIZIONE Apparecchio integrato da calendario e termometro adatto all installazione in prossimità di testaletto in normali scatole da incasso da parete o ...

Страница 4: ...arm sounds THERMOMETER function with indication in C Clock backup battery duration about 20 days with recharge able lithium buffer battery Timed back lit display activated by pressing one of the four buttons Multilingual menu Italian English French Spanish and German Protection degree IP40 Class II equipment Operating temperature 0 C 40 C Ambient temperature range during transport 25 C 60 C Clock ...

Страница 5: ...e 20 jours environ avec batterie tampon rechargeable au lithium Affichage digital temporisé activé en pressant l un des quatre poussoirs Menù en plusieurs langues italien anglais français español allemand Degré de protection IP40 Appareil de classe II Température de fonctionnement 0 C 40 C Température ambiante pendant le transport 25 C 60 C Erreur horloge 2 s par jour UTILISATION Pour programmer l...

Страница 6: ...utwerken THERMOMETER Funktion mit Angabe in C Reservebetrieb der Uhr ca 20 Tage durch aufladbare Lithiumpufferbatterien Display mit zeitlich gesteuerter Hintergrundbeleuchtung wird durch Bedienung einer der vier Tasten aktiviert Mehrsprachiges Menü Italienisch Englisch Französisch Spanisch und Deutsch Schutzstufe IP40 Gerät der Klasse II Betriebstemperatur 0 C 40 C Raumtemperatur während des Trans...

Отзывы: