14 - ENGLISH
3. INSTALLATION.
The appliance must be installed in flush or surface mounting boxes
with EIKON frames and plates at a height of 1 .5 m off the floor in
a suitable position for correctly detecting the ambient temperature .
It must not be installed in niches, behind doors and curtains or in
areas affected by sources of heat or atmospheric factors .
In par-
ticular, it must not be installed on outer walls or in association
with appliances that generate heat (e.g. dimmers or lamps).
It should be used in dry, dust-free places at a temperature between
0 °C and +40 °C .
1. DESCRIPTION.
Electronic thermostat for temperature control in the residential sector
(heating and air conditioning) . Input terminals for temperature reduc-
tion and for switching on with a phone dial .
6(2) A 230 V~ change-over relay output, power supply 120-230 V~
50-60 Hz - 2 modules .
2. FIELD OF APPLICATION.
The appliance is designed to control room temperature by acting on
the control circuit of the burner or circulation pump (heating) or on
the control circuit of the air conditioner (air conditioning) .
The large display shows the room temperature, system operating
status and mode (summer, winter, reduction) .
All the parameters are programmed with the 4 buttons on the front
of the appliance .
Содержание Eikon 20440
Страница 2: ......
Страница 4: ......
Страница 9: ...ITALIANO 5 5 COLLEGAMENTI 5 1 Schemi di collegamento L N U1 L N U1 APRE CHIUDE ...
Страница 16: ......
Страница 21: ...ENGLISH 17 5 CONNECTIONS 5 1 Connection diagrams L N U1 L N U1 OPEN CLOSE ...
Страница 28: ......
Страница 33: ...FRANÇAIS 29 5 RACCORDEMENTS 5 1 Schémas de raccordement L N U1 L N U1 OUVERT FERME ...
Страница 40: ......
Страница 45: ...DEUTSCH 41 5 ANSCHLÜSSE 5 1 Anschlussplan L N U1 L N U1 SCHLIESSEN ÖFFNEN ...
Страница 52: ......
Страница 57: ...ESPAÑOL 53 5 CONEXIONES 5 1 Esquemas de conexión L N U1 L N U1 ABIERTO CERRADO ...
Страница 64: ......
Страница 69: ...ΕΛΛΗΝΙΚА 65 5 ΣΥΝΔΕΣΕΙΣ 5 1 Σχεδιαγράμματα σύνδεσης L N U1 L N U1 ΑΝΟΙΓΑ ΚΑΕΙΣΙΜΟ ...