lower left LED (MAKE UP ROOM):

- Off if input I5 is not active.
- On at set brightness for standby if I5 is active.

■ 

upper central LED: always off.

■ 

lower central LED (door bell):

- Off if input I6 is active (DO NOT DISTURB).
- On at set brightness for standby if I6 is not active.

■ 

upper right LED (OUT = client out of room):

- Off if input I2 is not active.
- On at set brightness for standby if I2 is active.

■ 

lower right LED (DO NOT DISTURB):

- Off if input I6 is not active.
- On at set brightness for standby if I6 is active.

■ 

If a hand enters the proximity detection area, the device will be activated.

6.2.1 Activated

The colour and brightness of the LEDs is that set during configuration.

■ 

upper left LED (IN = client in room):

- Off if input I1 is not active.
- On at full brightness if I1 is active.

■ 

lower left LED (MAKE UP ROOM):

- Off if input I5 is not active.
- On at full brightness if I5 is active.

■ 

upper central LED: always off.

■ 

lower central LED (door bell):

- Off if input I6 is active (DO NOT DISTURB).
- On at full brightness if I6 is not active.

■ 

upper right LED (OUT = client out of room):

- Off if input I2 is not active.
- On at full brightness if I2 is active.

■ 

lower right LED (DO NOT DISTURB):

- Off if input I6 is not active.
- On at full brightness if I6 is active.

■ 

10 s after the hand is withdrawn from the proximity area, the device returns to standby.

Note:

 The only push button used in the lower central one (door bell). Pressing this push button (touch or physical), the device will activate output O4 for as long 

as the button is pressed; if the DO NOT DISTURB signal is enabled (I6 active) output O4 is disabled.

7. Installation rules

Installation should be carried out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the 
products are installed.

8. Regulatory compliance

EMC Directive. 
Standard EN 60669-2-1.

Installation rules - Regulatory compliance

WEEE - Information for users

If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn 
product to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a 
sales area of at least 400 m

2

, if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the 

potential negative effects on the environment and people’s health, and encourages the re-use and/or recycling of the construction materials.

Содержание 21125

Страница 1: ...21125 Electronic control unit 8 non polarised inputs 7 solid state outputs for non polarised contacts Installer manual...

Страница 2: ...2...

Страница 3: ...uts 8 4 RGB LEDs and pushbuttons 9 4 1 RGB LEDs 11 4 2 Push buttons 11 5 Configuration of the device 11 5 1 Setting the colours of the LEDs 11 5 2 Device setup 12 5 3 Factory reset 13 6 Operation 13 6...

Страница 4: ...ics Power supply Supply voltage 9 32 Vdc SELV Max absorbed power in power supply input 0 9 W Inputs Input activation voltage 5 32 Vdc Signal frequency PWM input 7 400 kHz if you wish to change the cur...

Страница 5: ...12 External room input wiring IMPORTANT Connect input 8 as always active otherwise the device will work as the internal room Input 1 Orange IN Client in room Input 3 Green Do not connect Input 5 Purpl...

Страница 6: ...lues The inputs common is to be connected directly to the power supply positive 9 32V 100mA INPUTS I2 I4 I6 I8 NC NC I1 I3 I5 I7 NC C IN O1 O2 O3 O4 O5 O6 NC O7 C OUT OUTPUTS C IN V V I1 I2 Example 2...

Страница 7: ...hat provides an output with voltage and current values compatible with the inputs of the 21125 electronic control unit The inputs common is to be connected directly to the negative of the power supply...

Страница 8: ...utput wiring Output 1 Orange DO NOT DISTURB Output 2 Yellow RE DO ROOM Output 3 Green Do not connect Output 4 Blue Do not connect Output 5 Purple Do not connect Output 6 Grey Do not connect Output 7 W...

Страница 9: ...ive most frequently used case The outputs can be connected to a third party device with internal pull up inputs The outputs common is to be connected directly to the power supply negative 9 32V 100mA...

Страница 10: ...UT 4 OUT 1 OUT 2 BELL DO NOT DISTURB SERVICE Art 01831 1 Art 20380 V Vo Adj V INPUT OUTPUT 100 240VAC 0 5A 50 60Hz 12V N L 1 25A 10 8 13 8V Max 1 25A Max 15Watt MEAN WELL Terminal torque 4 4 Lb in Ter...

Страница 11: ...25 electronic control unit presents six physical pushbuttons shown in blue and two configuration pushbuttons shown in red Once the cover plate has been fitted to the control the 6 touchscreen buttons...

Страница 12: ...At this point it is possible to modify the colour of each individual LED 2 Short press the pushbutton for which you want to set the colour of the relative LED each press of the pushbutton will cycle t...

Страница 13: ...up configuration procedure without saving any changes made Example The device illustrated below is set to low sensitivity and when in standby the LEDs illuminate with minimum brightness 5 3 Factory re...

Страница 14: ...upper left push button to enable disable the DO NOT DISTURB signal Press the upper right push button to enable disable the MAKE UP ROOM signal Outputs O1 and O2 follow the DO NOT DISTURB and MAKE UP R...

Страница 15: ...and is withdrawn from the proximity area the device returns to standby Note The only push button used in the lower central one door bell Pressing this push button touch or physical the device will act...

Страница 16: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 21125IEN 02 1901...

Отзывы: