• The LEDs of the central module indicate the sensitivity of the touchscreen when the device is used in combination with a cover plate; if the upper centre LED is on, 

sensitivity is high, and if the lower centre ED is on, sensitivity is low. 
To select the desired behaviour, simply press the relative pushbutton (the two central pushbuttons are mutually exclusive).

• The LEDs on the right module indicate the brightness of he the LEDs in standby; pressing the upper right pushbutton increases the brightness, while pressing the 

lower right pushbutton decreases it. 
The available options are: 

LEDs off

minimum brightness (default)

medium brightness

maximum brightness

.

The brightness of the LEDs changes immediately to show the new setting 

Once all the desired options have been selected, long press the lower configuration button to save the settings to memory.

N.B.

 If no operations are performed within the timeout of 10 s, the device will quit the setup configuration procedure without saving any changes made.

Example.
The device illustrated below is set to low sensitivity and, when in standby, the LEDs illuminate with minimum brightness.

5.3 Factory reset

Simultaneously long pressing all six pushbuttons resets the device to the factory settings; all other settings will be deleted. 

6. Operation

The device has two operating modes:
• Internal room.
• External room.
The operating mode is selected by activating or not activating input 

8

; if it is active the external room function is on, vice versa the internal room function is on.

6.1 Internal room

In this case the device is installed in the room and is used to enable the “DO NOT DISTURB” and "MAKE UP ROOM” signals.
Only the following are used:
•  4 signalling LEDs (the 2 LEDs in the left-hand module and the 2 LEDs in the right-hand module).
•  2 push buttons (lower left and upper right).
•  2 outputs (O1 and O2).

Left module

Central module

Right module

Upper pushbutton

DO NOT DISTURB push button

Always off

MAKE UP ROOM push button

Lower pushbutton

DO NOT DISTURB indicator

Always off

MAKE UP ROOM indicator

The device is normally in standby condition.

Operation

Содержание 21125

Страница 1: ...21125 Electronic control unit 8 non polarised inputs 7 solid state outputs for non polarised contacts Installer manual...

Страница 2: ...2...

Страница 3: ...uts 8 4 RGB LEDs and pushbuttons 9 4 1 RGB LEDs 11 4 2 Push buttons 11 5 Configuration of the device 11 5 1 Setting the colours of the LEDs 11 5 2 Device setup 12 5 3 Factory reset 13 6 Operation 13 6...

Страница 4: ...ics Power supply Supply voltage 9 32 Vdc SELV Max absorbed power in power supply input 0 9 W Inputs Input activation voltage 5 32 Vdc Signal frequency PWM input 7 400 kHz if you wish to change the cur...

Страница 5: ...12 External room input wiring IMPORTANT Connect input 8 as always active otherwise the device will work as the internal room Input 1 Orange IN Client in room Input 3 Green Do not connect Input 5 Purpl...

Страница 6: ...lues The inputs common is to be connected directly to the power supply positive 9 32V 100mA INPUTS I2 I4 I6 I8 NC NC I1 I3 I5 I7 NC C IN O1 O2 O3 O4 O5 O6 NC O7 C OUT OUTPUTS C IN V V I1 I2 Example 2...

Страница 7: ...hat provides an output with voltage and current values compatible with the inputs of the 21125 electronic control unit The inputs common is to be connected directly to the negative of the power supply...

Страница 8: ...utput wiring Output 1 Orange DO NOT DISTURB Output 2 Yellow RE DO ROOM Output 3 Green Do not connect Output 4 Blue Do not connect Output 5 Purple Do not connect Output 6 Grey Do not connect Output 7 W...

Страница 9: ...ive most frequently used case The outputs can be connected to a third party device with internal pull up inputs The outputs common is to be connected directly to the power supply negative 9 32V 100mA...

Страница 10: ...UT 4 OUT 1 OUT 2 BELL DO NOT DISTURB SERVICE Art 01831 1 Art 20380 V Vo Adj V INPUT OUTPUT 100 240VAC 0 5A 50 60Hz 12V N L 1 25A 10 8 13 8V Max 1 25A Max 15Watt MEAN WELL Terminal torque 4 4 Lb in Ter...

Страница 11: ...25 electronic control unit presents six physical pushbuttons shown in blue and two configuration pushbuttons shown in red Once the cover plate has been fitted to the control the 6 touchscreen buttons...

Страница 12: ...At this point it is possible to modify the colour of each individual LED 2 Short press the pushbutton for which you want to set the colour of the relative LED each press of the pushbutton will cycle t...

Страница 13: ...up configuration procedure without saving any changes made Example The device illustrated below is set to low sensitivity and when in standby the LEDs illuminate with minimum brightness 5 3 Factory re...

Страница 14: ...upper left push button to enable disable the DO NOT DISTURB signal Press the upper right push button to enable disable the MAKE UP ROOM signal Outputs O1 and O2 follow the DO NOT DISTURB and MAKE UP R...

Страница 15: ...and is withdrawn from the proximity area the device returns to standby Note The only push button used in the lower central one door bell Pressing this push button touch or physical the device will act...

Страница 16: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 21125IEN 02 1901...

Отзывы: