Wiring and Schematics
Convection Fan Current Flow
Convection Fan – Reverse – High Speed
When the board selects a reverse high speed, the K5 relay sends L1 through the K6 N.O. contact (now
closed), then out to the REV terminal and straight into the motor. L1 is also sent into the K7 relay through
the N.O. contact (now closed) and then out to the HI terminal. It then enters the 1st capacitor. The phased
current travels to the motor. The motor will run at High speed (ccw).
Convection Fan – Reverse – Low Speed
When the board selects a reverse low speed, the K5 relay sends L1 through the K6 N.O. contact (now
closed), then out to the REV terminal and straight into the motor. L1 is also sent into the K7 relay through
the N.C. contact and then out to the LO terminal. It then enters the 1st capacitor. The phased power exiting
the 1st capacitor then enters the 2nd one. The phased current then travels to the motor. The motor will run
at Low speed (ccw).