30
7:30 Ejection Position
Contamination—Motor will not oscillate
Replace Ice Maker
Shut-off arm stuck in ice or obstructed
Unjam
Cubes not formed properly
Check fill cup and fill assembly
9:00 Ejection Position
Contaminated
Replace Ice Maker
Cube frozen to fill cup or mold
Unjam
Replace fill cup and replace Ice Maker
Excessive Ice Production
Problem
Action
Shut-off arm not in actuator
Replace shut-off arm in actuator
Deformed shut-off arm
Replace shut-off arm
Broken shut-off lever or lever bypassing
Replace Ice Maker
vertical
cam
Broken module actuator
Replace Ice Maker
Hollow Ice Cubes
Problem
Action
Low water fill volume
Adjust module screw, clear water path, or
replace
water
valve
Improper freezer air flow
Direct air flow away from thermostat
Thermostat out of calibration
Replace Ice Maker