Display Panel Operation (

con’t

 
Lower Temp Pad 

Lowers temperatures setting one bar at a time.  If 
entry tone is on, tone will sound at each bar level 
until bottom level is reached. 
1.  Turn on temperature setting function of control 

panel be pressing Lower Temp Pad. 

2.  Press and hold Lower Temp Pad to lower 

temperature setting at a faster rate. 

 

Max Frz Pad 

Activates Maximum freezer mode setting freezer 
temperature to coldest setting for 24 hours or until 
Max Frz pad is pressed again. 
1.  Freezer indicator light will glow. 
2.  To adjust maximum freezer mode time refer to 

Program Mode B functions. 

 

Max Ref Pad 

Activates Maximum refrigerator mode setting 
refrigerator to coldest setting for 24 hours or until 
Max Ref Pad is pressed again. 
1.  Refrigerator indicator light will glow. 
2.  To adjust maximum refrigerator time refer to 

Mode B functions. 

 

Alarm Off Pad 

Turns off alarm signals.  See Alarms section to 
interpret alarm signals. 
1.  Press and hold Alarm Off pad for 3 seconds to 

deactivate Door Open alarm.  To reactivate Door 
Open alarm, press and hold Alarm Off pad for 3 
seconds. 

2.  If Alarm Off pad is pressed and condition 

causing alarm is not corrected, alarm will reset. 

 

Hidden Button 

Activates Program Mode.  See Program Mode 
section for description of functions available. 
1.  Open refrigerator door. 
2.  Press Display On pad. 
3.  Press hidden button pad. 
4.  Within 6 seconds press the following pads in this 

sequence:  Max Ref, Max Frz, Max Ref, Max 
Frz. 

5.  Tone will sound 3 times and control will be in 

program mode A. 

 

 Display Off Pad 

1.  Deactivates control panel. 
2. Deactivates temperature indication area of 

control panel. 

 

Electronic Functional Description 
 

 
Power Disconnect Switch 

Use power disconnect switch to disconnect power 
without unplugging refrigerator.  Power disconnect 
switch is located behind air grille on top right side. 
Refrigerator is shipped with power disconnect switch 
in the On position. 
 

Showroom Switch 

Showroom switch allows electronic controls and 
interior lights to function independently of 
refrigeration system.  Showroom switch is located 
behind air grill to right of control panel.  Refrigerator 
is shopped with showroom switch in unit run 
position. 
 

Alarms 

 

 

Power Up Alarm 

After power is initially plugged in, after a power loss, 
or if power switch is turned off, all temperature 

indicator lights will flash until Alarm Off or Display 
On is pressed. 

Note:

 All settings return to default factory settings. 

 

Door Open Alarm 

Alarm tone sounds and indicator lights blink if either 
refrigerator or freezer door is open more than 3 
minutes. 
1.  Turn off Door  Open alarm by pressing Alarm 

Off pad or by closing door. 

2.  Deactivate door open alarm by pressing Display 

On pad and then press and hold Alarm Off pad 
for 3 seconds. 

3.  Door alarm delay can be adjusted in Program 

Mode B. 

 

High Temperature Alarm 

Alarm sounds and indicator light shows if freezer or 
refrigerator temperature has gone above critical level 
and remained warm for 2 hours.  Alarm tone stops if 
temperature falls again. 

 

 

Содержание VCSB48

Страница 1: ...SERVICE NOTEBOOK BUILT IN REFRIGERATOR VCSB481 VCSB482 VIKING RANGE CORPORATION PO DRAWER 956 GREENWOOD MS 38930 USA...

Страница 2: ...ezer Compartment Theory of Operation 18 Wiring Diagram 19 Refrigeration Compartment Theory of Operation 19 Wiring Diagram 20 Refrigeration and Freezer Compartment Theory of Operation 20 Wiring Diagram...

Страница 3: ...rthing and polarization After servicing reconnect power using power switch Model VCSB481SS Capacity 28 57 cu ft Electrical 120 VAC Requirements 60 Hz Separate Circuit 15 Amp Refrigerant type 134A Widt...

Страница 4: ...5 REFRIGERANT FLOW...

Страница 5: ...6...

Страница 6: ...7 MACHINE COMPARTMENT AIR FLOW...

Страница 7: ...mps Thermister Check resistance across Terminals Bell curve Resistance see page 13 77 F 30 000 ohms 1 ohms 45 F 68 000 ohms 2 ohms Thermostat Volt 120VAC Watt 1000 Watts Current 10 Amps Resistance acr...

Страница 8: ...Type Fan cooled R134a refrigerant BTUH 970 BTUH Volts 120VAC 60Hz Watt 176 watts Current Lock rotor 21 3 A Full load 6 A Resistance Run windings 2 60 Start windings 4 35 Drier Drier must be changed ev...

Страница 9: ...facing shaft Counterclockwise evaporator fan RPM 3300 RPM Watt 1 4 Watts Overload Volt 120VAC Ult Trip amps 158 F 70 C 3 51 Amps Close temperature 142 F 61 C 9 Open temperature 257 F 125 C 5 Short ti...

Страница 10: ...er temperature setting mode 1 Freezer indicator light will glow Freezer temperature setting will be displayed Factory setting is 5 2 Change freezer temperature setting by pressing Higher Temp or Lower...

Страница 11: ...in this sequence Max Ref Max Frz Max Ref Max Frz 5 Tone will sound 3 times and control will be in program mode A Display Off Pad 1 Deactivates control panel 2 Deactivates temperature indication area o...

Страница 12: ...gerator thermistors Refrigerator and Freezer Thermistor As temperature decreases resistance increases As temperature increases resistance decreases Open thermistor or thermistor circuit will result in...

Страница 13: ...le Six minutes dwell time occurs after defrost terminator opens before compressor and condenser fan motor will operate Ten minute dwell time occurs after defrost terminator opens before evaporator fan...

Страница 14: ...un time duration in 4 hours increments indicator 1 means 4 hours 2 means 8 hours etc Default delay is 24 hours 2 Press Higher Temp pad to decrease Max Frz duration by 4 hours 3 Press Lower Temp pad to...

Страница 15: ...anel 2 Simultaneously press and hold Max Ref and Display Off pads for 3 seconds Forced Compressor Start 1 Press Display On pad to activate control panel 2 Simultaneously press and hold Max Frz pad and...

Страница 16: ...CK WHICH CAN CAUSE SEVERE INJURY OF DEATH DISCONNECT POWER TO REFRIGERATOR USING POWER SWIDTCH BEFORE SERVICING WIRES REMOVED DURING DISASSEMBLY MUST BE REPLACED ON PROPER TERMINALS TO INSURE EARTHING...

Страница 17: ...17...

Страница 18: ...low voltage signals one to the compressor relay coil C1 and one to the evaporator relay coil E1 When both relay coils are energized and both relay contacts are closed high voltage circuits to evaporat...

Страница 19: ...al to semiconductor switch for DC fresh food fan and DC condensate evaporator fan Both fans begin operating Fresh food fan circulates freezer air into fresh food compartment Condensate evaporator fan...

Страница 20: ...sate evaporator fans After freezer thermistor cools sufficiently to raise resistance and block the signal to the electronic control compressor condenser fan motor will shut off However fresh food and...

Страница 21: ...ng high voltage circuit to defrost heater through closed defrost terminator closes at 15 F Isolator which is part of high voltage PC board recognizes presence of line voltage to defrost heater and sen...

Страница 22: ...22...

Страница 23: ...ermostat Close 17 3 F 8 1 C Bimetal Opens 32 3 F 0 1 C Water fill 140 cc 7 5 sec Motor cycle Stamped in circuit Plug in connectors One revolution of blades takes 3 minutes plug stall time on ice eject...

Страница 24: ...sconnect power to refrigerator using power switch before servicing Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization After servicing rec...

Страница 25: ...t be in on position There are several slotted shafts on motor assembly board Do not insert screwdriver and attempt to turn shafts Slots permit assembly only There are non repairable and non replaceabl...

Страница 26: ...r temperatures above normal 0 2 F 18 1 C will slow down ice production Increase ice production by setting freezer to colder setting Thermostat cycling temperature 1 revolution ice maker is 17 3 F 8 1...

Страница 27: ...ming cam Inside valve is a flow washer which acts as a water pressure regulator Proper ice maker fill is 140cc 10cc at 7 5 seconds of water fill at an inlet pressure ranging from 20 to 120 PSI 1 4 to...

Страница 28: ...tube cup assembly Frozen fill tube Replace water valve Kinked water line Un kink line and check line for weak sections Obstructed water line to ice maker or Clear water line refrigerator Clogged water...

Страница 29: ...l level refrigerator or ice maker No power to ice maker Determine discontinuity be tracing power Excessive water fill volume Adjust module screw lower water pressure or replace water valve Cubes falli...

Страница 30: ...replace Ice Maker Excessive Ice Production Problem Action Shut off arm not in actuator Replace shut off arm in actuator Deformed shut off arm Replace shut off arm Broken shut off lever or lever bypass...

Страница 31: ...jection position Contaminated module Replace Ice Maker Refrigerator or ice maker not level Level refrigerator or ice maker Excessive water pressure Decrease water pressure 20 120 psi 1 4 8 2 bar Short...

Страница 32: ...32...

Страница 33: ...a Microsoft Templates Normal dot Title Subject Author Viking Range Keywords Comments Creation Date 10 25 2001 8 30 AM Change Number 2 Last Saved On 3 28 2003 4 01 PM Last Saved By Ken Sievert Total Ed...

Отзывы: