background image

 

14

Mode A Functions (con’t) 
  
Freezer Thermistor Temperature 

1.  Choose freezer thermistor temperature display by 

pressing Freezer Temp pad. 

2.  Freezer thermistor temperature displays. 
 

Refrigerator Thermistor Temperature 

1.  Choose Refrigerator Thermistor temperature 

display by pressing Ref Temp pad. 

2.  Refrigerator thermistor temperature displays. 
 

Mode B Functions 
 
Automatic Keyboard Functions 

Activate and deactivate keyboard by toggling Display 
Off pad.  If high temperature indicator glows, 
keyboard will disable after 10 minutes.  If high 
temperature indicator is off, keyboard is always 
enabled.  DO NOT LEAVE KEYBOARD IN 
ENABLED MODE AFTER PROGRAMMING IS 
COMPLETE 
 

Door Alarm Delay 

1.  Press Alarm Off pad.  Door open indicator will  

glow.  One temperature indicator should glow 
indicating present delay setting in minutes 
(indicator 1 means 1 minute, 2 means 2 minutes, 
etc.)  Default delay is 3 minutes. 

2.  Press Higher Temp pad to decrease delay by 1 

minute. 

3.  Press Lower Temp pad to increase delay by 1 

minute. 

 

Max Ref Run Time Duration 

1.  Press Max Ref pad.  Max Ref light will glow.  

One temperature indicator should glow 
indicating present Max Ref run time duration in 
2 hour increments (indicator 1 means 2 hours, 2 
means 4 hours, etc.)  Default delay is 10 hours. 

2.  Press Higher Temp pad to decrease Max Ref 

duration by 2 hours. 

3.  Press Lower Temp pad to increase Max Ref 

duration by 2 hours. 

 

Max Frz Run Time Duration 

1.  Press Max Frz pad.  Max Fra light will glow.  

One temperature indicator should glow 
indicating present Max Frz run time duration in 4 
hours increments (indicator 1 means 4 hours, 2 
means 8 hours, etc.)  Default delay is 24 hours. 

2.  Press Higher Temp pad to decrease Max Frz 

duration by 4 hours. 

3.  Press Lower Temp pad to increase Max Frz 

duration by 4 hours. 

 

Temperature Offset Calibration 

Offset amount adjusts temperatures for refrigerator 
cut-ins and cut-outs by the amount of offset.  The 
chart below shows the indicator and the amount of 
offset from the factory default setting. 

 

Setting Refrigerator Temperature Offset 
Press Ref Temp pad.  Refrigerator indicator and 
one indicator will glow.  Press Higher Temp pad 
to move offset to the next warmer setting.  Press 
Lower Temp pad to move offset to the next 
colder setting.  Factory default refrigerator offset 
is –4. 

 

 Setting Freezer Temperature Offset 

 

Press Freezer Temp pad.  Freezer temperature 
indicator and one indicator will glow.  Press 
Higher Temp pad to move offset to the next 
warmer setting.  Press Lower Temp pad to move 
offset to the next colder setting.  Factory default 
freezer offset is 0. 

 

Defrost Mode Selection 

Toggle Hidden Button pad to select adaptive or 
conventional defrost mode.  Hidden Button indicator 
glows when adaptive defrost has been selected.  If 
Hidden Button indicator is off, conventional defrost 
is selected.  Conventional defrost uses 8 hour CRTD 
value. 
 

Forced Defrost 

Defrost can be forced to start by pressing and holding 
the Alarm Off pad for 3 seconds.  Program changes 
will be saved permanently in EEPROM and program 
mode will exit to Run Mode. 
 

Forced Pull Down 

Compressor start can be forced by pressing and 
holding Max Frz pad for 3 seconds.  Program 
changes will be saved permanently in EEPROM.  
Compressor, evaporator fan and condenser fan will 
come on. 

 

Содержание VCSB48

Страница 1: ...SERVICE NOTEBOOK BUILT IN REFRIGERATOR VCSB481 VCSB482 VIKING RANGE CORPORATION PO DRAWER 956 GREENWOOD MS 38930 USA...

Страница 2: ...ezer Compartment Theory of Operation 18 Wiring Diagram 19 Refrigeration Compartment Theory of Operation 19 Wiring Diagram 20 Refrigeration and Freezer Compartment Theory of Operation 20 Wiring Diagram...

Страница 3: ...rthing and polarization After servicing reconnect power using power switch Model VCSB481SS Capacity 28 57 cu ft Electrical 120 VAC Requirements 60 Hz Separate Circuit 15 Amp Refrigerant type 134A Widt...

Страница 4: ...5 REFRIGERANT FLOW...

Страница 5: ...6...

Страница 6: ...7 MACHINE COMPARTMENT AIR FLOW...

Страница 7: ...mps Thermister Check resistance across Terminals Bell curve Resistance see page 13 77 F 30 000 ohms 1 ohms 45 F 68 000 ohms 2 ohms Thermostat Volt 120VAC Watt 1000 Watts Current 10 Amps Resistance acr...

Страница 8: ...Type Fan cooled R134a refrigerant BTUH 970 BTUH Volts 120VAC 60Hz Watt 176 watts Current Lock rotor 21 3 A Full load 6 A Resistance Run windings 2 60 Start windings 4 35 Drier Drier must be changed ev...

Страница 9: ...facing shaft Counterclockwise evaporator fan RPM 3300 RPM Watt 1 4 Watts Overload Volt 120VAC Ult Trip amps 158 F 70 C 3 51 Amps Close temperature 142 F 61 C 9 Open temperature 257 F 125 C 5 Short ti...

Страница 10: ...er temperature setting mode 1 Freezer indicator light will glow Freezer temperature setting will be displayed Factory setting is 5 2 Change freezer temperature setting by pressing Higher Temp or Lower...

Страница 11: ...in this sequence Max Ref Max Frz Max Ref Max Frz 5 Tone will sound 3 times and control will be in program mode A Display Off Pad 1 Deactivates control panel 2 Deactivates temperature indication area o...

Страница 12: ...gerator thermistors Refrigerator and Freezer Thermistor As temperature decreases resistance increases As temperature increases resistance decreases Open thermistor or thermistor circuit will result in...

Страница 13: ...le Six minutes dwell time occurs after defrost terminator opens before compressor and condenser fan motor will operate Ten minute dwell time occurs after defrost terminator opens before evaporator fan...

Страница 14: ...un time duration in 4 hours increments indicator 1 means 4 hours 2 means 8 hours etc Default delay is 24 hours 2 Press Higher Temp pad to decrease Max Frz duration by 4 hours 3 Press Lower Temp pad to...

Страница 15: ...anel 2 Simultaneously press and hold Max Ref and Display Off pads for 3 seconds Forced Compressor Start 1 Press Display On pad to activate control panel 2 Simultaneously press and hold Max Frz pad and...

Страница 16: ...CK WHICH CAN CAUSE SEVERE INJURY OF DEATH DISCONNECT POWER TO REFRIGERATOR USING POWER SWIDTCH BEFORE SERVICING WIRES REMOVED DURING DISASSEMBLY MUST BE REPLACED ON PROPER TERMINALS TO INSURE EARTHING...

Страница 17: ...17...

Страница 18: ...low voltage signals one to the compressor relay coil C1 and one to the evaporator relay coil E1 When both relay coils are energized and both relay contacts are closed high voltage circuits to evaporat...

Страница 19: ...al to semiconductor switch for DC fresh food fan and DC condensate evaporator fan Both fans begin operating Fresh food fan circulates freezer air into fresh food compartment Condensate evaporator fan...

Страница 20: ...sate evaporator fans After freezer thermistor cools sufficiently to raise resistance and block the signal to the electronic control compressor condenser fan motor will shut off However fresh food and...

Страница 21: ...ng high voltage circuit to defrost heater through closed defrost terminator closes at 15 F Isolator which is part of high voltage PC board recognizes presence of line voltage to defrost heater and sen...

Страница 22: ...22...

Страница 23: ...ermostat Close 17 3 F 8 1 C Bimetal Opens 32 3 F 0 1 C Water fill 140 cc 7 5 sec Motor cycle Stamped in circuit Plug in connectors One revolution of blades takes 3 minutes plug stall time on ice eject...

Страница 24: ...sconnect power to refrigerator using power switch before servicing Wires removed during disassembly must be replaced on proper terminals to insure correct earthing and polarization After servicing rec...

Страница 25: ...t be in on position There are several slotted shafts on motor assembly board Do not insert screwdriver and attempt to turn shafts Slots permit assembly only There are non repairable and non replaceabl...

Страница 26: ...r temperatures above normal 0 2 F 18 1 C will slow down ice production Increase ice production by setting freezer to colder setting Thermostat cycling temperature 1 revolution ice maker is 17 3 F 8 1...

Страница 27: ...ming cam Inside valve is a flow washer which acts as a water pressure regulator Proper ice maker fill is 140cc 10cc at 7 5 seconds of water fill at an inlet pressure ranging from 20 to 120 PSI 1 4 to...

Страница 28: ...tube cup assembly Frozen fill tube Replace water valve Kinked water line Un kink line and check line for weak sections Obstructed water line to ice maker or Clear water line refrigerator Clogged water...

Страница 29: ...l level refrigerator or ice maker No power to ice maker Determine discontinuity be tracing power Excessive water fill volume Adjust module screw lower water pressure or replace water valve Cubes falli...

Страница 30: ...replace Ice Maker Excessive Ice Production Problem Action Shut off arm not in actuator Replace shut off arm in actuator Deformed shut off arm Replace shut off arm Broken shut off lever or lever bypass...

Страница 31: ...jection position Contaminated module Replace Ice Maker Refrigerator or ice maker not level Level refrigerator or ice maker Excessive water pressure Decrease water pressure 20 120 psi 1 4 8 2 bar Short...

Страница 32: ...32...

Страница 33: ...a Microsoft Templates Normal dot Title Subject Author Viking Range Keywords Comments Creation Date 10 25 2001 8 30 AM Change Number 2 Last Saved On 3 28 2003 4 01 PM Last Saved By Ken Sievert Total Ed...

Отзывы: