To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Rack Support Removal
1. Remove oven door (see Door Assembly
Removal).
2. Remove screws and rack support from holes in
back wall of oven cavity.
3. Reverse procedure for installation.
Convection Fan Cover Removal
1. Remove one oven rack support (see Rack
Support Removal).
2. Remove screws and fan cover from oven cavity.
3. Reverse procedure for installation.
Smoke Eliminator Removal
1. Remove convection fan cover (see Convection
Fan Cover Removal).
2. Remove screws that hold the smoke eliminator
to the top, left, rear corner of the oven liner.
3. Pull down to remove smoke eliminator from
oven.
4. Reverse procedure for installation.
Convection Fan Assembly Removal
1. Remove convection fan cover (see
Convection Fan Cover Removal).
2. Remove screws and set convection fan
assembly on oven liner.
3. Disconnect connector and remove
convection fan assembly from oven cavity.
Note:
The mounting hole pattern for the convection
fan assembly is NOT symmetrical. Line up holes
before installing.
4. Reverse procedure for installation.
Disassembly