background image

Symptom

Possible Cause

Corrective Action

Blower motor inoperable.

Open blower motor.

Replace blower motor.

Oven sensor out of calibration.

Replace oven sensor. 

Open relay K8 or K9.

Replace oven control board.

Open oven control board.

Replace oven control board.

Defective oven wiring (shorted, 

open, or burned).

Repair or replace defective wiring.

LED Error Codes

The LED error codes are displayed on the control panel using the cycle and clean lights. Refer to the chart below to 
determine the type of error that is being displayed.

LED Error Codes

Type of error

Cycle Light

Clean Light

Latch

OFF

1 flash

RTD 

(Oven Probe)

1 flash

OFF

Model

2 flashes

 

(The model header failure only occurs at power up of unit. 

Install correct header and restart power up.)

ON

Cooling Fan

3 flashes

ON

High Limit

4 flashes

ON

Troubleshooting

©2012 Viking Preferred Service

31

Содержание RDSCE230-5B

Страница 1: ...is to be used by qualified appliance technicians only Viking does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified person Th...

Страница 2: ...nite Switch Connections 27 Triple Infinite Switch Voltage Measurements 28 Troubleshooting Guide 29 LED Error Codes 31 Selector and Thermostat Characteristics 32 Access Control Board Assembly 33 Contro...

Страница 3: ...ill be preceded by the safety alert symbol and the word DANGER WARNING or CAUTION These words mean IMMEDIATE HAZARDS WHICH WILL RESULT IN SEVERE PERSONAL INJURY OR DEATH Hazards or unsafe practices wh...

Страница 4: ...ance before operating it Keep area around appliance clear and free from combustible materials gasoline and other flammable vapors and materials If appliance is installed near a window proper precautio...

Страница 5: ...or gasket is essential for a good seal Care should be taken not to rub damage or move the gasket DO NOT use oven cleaners of any kind in or around any part of the self clean oven Before self cleaning...

Страница 6: ...vent or surrounding areas until they have had sufficient time to cool Other potentially hot surfaces include rangetop areas facing the rangetop oven vent surfaces near the vent opening oven door area...

Страница 7: ...n the high density insulation used in the oven When the insulation is thoroughly cured this odor will disappear During subsequent self cleaning cycles you may sense an odor characteristic of high temp...

Страница 8: ...0 30 Wide 05 10 12 C00036178 Self Cleaning R D S C E 2 3 0 5 B S S D3 Stainless Steel Serial Number Model Number VOLTAGE Hz WATTS AMPS 240VAC 60 Hz 15 2 KW MAX 63 3 208VAC 60 Hz 11 4 KW MAX 54 8 MODEL...

Страница 9: ...unless test procedures require power to be connected Discharge capacitor through a resistor before attempting to service Ensure all ground wires are connected before certifying unit as repaired and o...

Страница 10: ...ement K17 yellow P6 violet 240 VAC 22 7 Outer Bake Element K17 yellow P5 Blue 240 VAC 37 5 Inner Bake Element K17 yellow P5 orange 240 VAC 38 RTD Resistive Thermal Device P14 violet P14 grey n a 1100...

Страница 11: ...sent to the relay This does not indicate however that the relay is functioning To check the relay contacts verify input voltage to the relay between the red wire L2 and black wire L1 at the connector...

Страница 12: ...he individual element relays are energized L1 black power is sent through the relay to the bake elements L2 power is controlled by the line break relay Inner Bake Relay Select a cooking program When t...

Страница 13: ...m main power supply and the violet wire goes to the inner broil element With the power off and Molex connector removed from the P6 control board connection use an ohmeter to measure resistance between...

Страница 14: ...power and remove the P6 Molex plug Reconnect power and using your ohmeter check for continuity between the two relay contacts refer to photo above If you read infinite ohms when the relay is energized...

Страница 15: ...lect a cooking program When the convection relay contact is energized red LED lit at base of relay check for 240 VAC between the yellow wire at the line break relay and the white red wire on P2 If 0 V...

Страница 16: ...ies coil voltage is being sent to that particular relay This does not indicate however that the relays are functioning To test connect power With your meter set for AC voltage check between P1 white o...

Страница 17: ...ay It is an SPDT relay When not energized the LO circuit is energized through C terminal of the K7 relay This will cause both capacitors to be in series causing the fan to run at a reduced speed The p...

Страница 18: ...nd K6 of the oven control board are functioning properly When K7 is at rest testing between LO and L2 should show a voltage reading of 240 VAC The red LED in front of the relay will NOT be lit When K7...

Страница 19: ...or One side of the motor is wired directly to L2 red wire L1 power to the lock motor is connected on the P12 connector DL on the main control board When the relay energizes L1 power is sent to the loc...

Страница 20: ...line break relay and the black white wire at P12 The resistance should be approximately 12 5K ohms If no resistance is read remove the latch motor to repair replace Follow the latch motor disassembly...

Страница 21: ...tor cam Shown below are the switch positions and wire colors To test check continuity between the blue white and brown wires The reading should be 0 ohms The S2 switch is N O and will read infinite oh...

Страница 22: ...d The violet and grey wires go to the oven sensor With the Molex plug removed use an ohmeter to measure resistance between the violet and grey wires in the Molex connector At ambient temperature you s...

Страница 23: ...through a resistor before attempting to service Ensure all ground wires are connected before certifying unit as repaired and or operational WARNING 4 S2 EGO P1 P2 S1 TOP 2 PILOT 4 2b S P1 PILOT P2 OF...

Страница 24: ...Switch contact Signal Voltage Wire color code P1 L1 120 VAC to neutral Black P2 L2 120 VAC to neutral Red P1 to P2 Line voltage input 240 VAC Black to Red 2 L1 when thermostat closes to element 120 v...

Страница 25: ...attempting to service Ensure all ground wires are connected before certifying unit as repaired and or operational WARNING Dual Infinite Switch Connections 4 S2 EGO P1 P2 S1 TOP 2 4a P1 S2 4a 4 2 S1 O...

Страница 26: ...de P1 L1 120 VAC to neutral Black P2 L2 120 VAC to neutral Red P1 to P2 Line voltage input 240 VAC Black to Red 2 L1 when thermostat closes to element 120 vac when thermostat closes to neutral Yellow...

Страница 27: ...ground wires are connected before certifying unit as repaired and or operational WARNING 4 S2 EGO P1 P2 S1 TOP 2 4a 4b 4 OFF Low 6 Detented High 100 Detented Low 6 Detented Low 6 Detented High 100 Det...

Страница 28: ...L1 when thermostat closes to element 120 vac when thermostat closes to neutral Yellow 4 L2 when thermostat closes to element 120 vac when thermostat closes to neutral Black White 4a L2 when thermosta...

Страница 29: ...e thermostat Open relay K12 K13 or K17 Replace oven control board Open oven control board Replace oven control board Defective oven wiring shorted open or burned Repair or replace defective wiring No...

Страница 30: ...control board Open oven control board Replace oven control board Defective oven wiring shorted open or burned Repair or replace defective wiring No self clean bake and broil operate normally oven lig...

Страница 31: ...efective wiring LED Error Codes The LED error codes are displayed on the control panel using the cycle and clean lights Refer to the chart below to determine the type of error that is being displayed...

Страница 32: ...VDC 2 72 kW 1 26 VDC Low Broil 10 0 kW 5 VDC 8 28 kW 4 21 VDC 1 58 kW 0 77 VDC Self Clean 10 0 kW 5 VDC 9 41 kW 4 82 VDC 443 W 0 22 VDC Resistance checks are made on the selector wire harness with the...

Страница 33: ...hole screws 2 Remove keyhole screws and lower access grill from range 3 Remove screws and slide control panel assembly from range Note During installation make sure the tabs on the control panel are a...

Страница 34: ...supplied with unit in pin holes Important For personal safety only use pins supplied with unit Pins can be ordered if needed 005116 000 2 Remove screws and hinge trim from range 3 Gently close door un...

Страница 35: ...crews and slide end caps from handle Note View set screw markings thru end cap holes then install set screws 4 Reverse procedure for installation Inner Door Glass Removal 1 Remove outer door panel ass...

Страница 36: ...al 2 Remove screws that attach the sensor to the back of the oven liner 3 Pull the sensor connector into the oven cavity and disconnect sensor connector Note During removal or install it may be helpfu...

Страница 37: ...l 2 Remove screws and fan cover from oven cavity 3 Reverse procedure for installation Smoke Eliminator Removal 1 Remove convection fan cover see Convection Fan Cover Removal 2 Remove screws that hold...

Страница 38: ...ews that hold the broil assembly to the top of the oven liner Note Use care when pulling broil assembly into the oven cavity Make sure the connectors remain on the broil assembly 5 Carefully pull conn...

Страница 39: ...sconnect connector from the oven thermostat 3 Remove screws bezel and thermostat from control panel 4 Reverse procedure for installation Indicator Light Removal 1 Access control components see Control...

Страница 40: ...g volt and wattage requirements listed on glass cover 4 Replace the light cover by snapping glass cover onto metal box 1 2 3 4 Top Light Housing Removal 1 Access control components see Control Compone...

Страница 41: ...panel aside to prevent any possible damage 3 Remove two front screws shown below in photos 4 Slide the top forward about two inches to release tabs that are underneath shoulder screws Lift top off of...

Страница 42: ...e 5 Reverse procedure for installation Back Panel Removal 1 Remove backguard assembly 4 screws 2 Remove screws and access door from back cover Side Trim and Side Panel Removal 1 Remove Door see Door A...

Страница 43: ...l from range 6 Slide grommet with power cord from panel 7 Reverse procedure for installation Cooling Blower Motor Removal 1 Remove back panel see Back Panel Removal 2 Remove three screws from blower m...

Страница 44: ...Black Black Red White Red White Red White Red White Red White Red Red Red Red Red Black Black Black Black Black Wht Vio Blue Orange Red Red Red Violet Yellow Violet Yellow Grey 4 Violet White Red 3 4...

Страница 45: ...Wiring Diagrams 2012 Viking Preferred Service 45...

Страница 46: ...Wiring Diagrams 46 2012 Viking Preferred Service...