background image

14

Printed in the U.S.A.

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666

Our Technical Support Department is available for assistance Monday to Friday 8am - 5pm central time. So we can give you better service, before you call please:

1.

Know the model number, the serial number and what software version you have (see serial label).

2. 

Have your Product Manual in front of you.

3. 

It is best if you are on site.

RETURNING PRODUCT FOR REPAIR

The following procedure is for equipment that needs repair:
1. 

Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a

complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem,
frequency of failure, etc.

2. 

Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board

should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking
to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to:  

Viking Electronics, 1531

Industrial Street,  Hudson, WI  54016
3.

Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.

4.

RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned. 

RETURNING PRODUCT FOR EXCHANGE

The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1.  

Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through

recommended tests for diagnosis.

2. 

If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization

(R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.

3. 

After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the Viking

product using the same R.A. number.

4.  The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3,
be aware that you will have to pay a restocking charge. 

TWO YEAR LIMITED WARRANTY

Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two

years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed
defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016.  Customer must contact
Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.

This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence

or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been
exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained.

NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE

AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER,

OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED
TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER.

EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING

NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR
OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY
AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.

IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES

FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF
LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT
OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.

DOD# 582

ZF303580 Rev A

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates
and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued
to incorporate such changes.

Warranty

Product Support: (715) 386-8666

PART 15 LIMITATIONS

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.

Содержание RC-4A

Страница 1: ...1 to 99 seconds can be activated Terminal strip connections for all four sensor inputs Notification by email or text message of sensor input state change Can be used as a secure remote relay for Viki...

Страница 2: ...ecure but may not work with some browsers or smartphones Client A computer or device that makes use of a server As an example the client might request a particular file from the server DHCP Dynamic Ho...

Страница 3: ...he MAC address printed on the unit s network jack or by looking at the device name Important If more than one RC 4A will be installed on the network each unit must be assigned its own unique device na...

Страница 4: ...changed It s when the user is logged in as an Administrator that Dipswitch 2 makes a difference If Dipswitch 2 is OFF programming is permitted If Dipswitch 2 is ON programming is blocked even when th...

Страница 5: ...dialog appears For User Name enter admin and for Password enter viking The main page appears Note that all four remote sensor inputs are shown Open and the relays are all Off The relays may be toggled...

Страница 6: ...the On position When their times are up they will return to the Off position The RC 4A also provides a status indication for the four inputs on the input terminal block In the picture below Input 1 an...

Страница 7: ...button is clicked Note that these times can be overridden by entering another value in the timed closures box on the main page and clicking Start The next time the main page is activated however the...

Страница 8: ...o change Click on OK On the dialog that appears next check the box for Prevent this page from creating additional dialogs It should be noted that this method of operation is not secure and should only...

Страница 9: ...ail notification of input events The RC 4A can be programmed to send an email if one of the inputs closes and also if it opens As described in Programming A Settings 2 Input Status Phrasing the input...

Страница 10: ...r sms alltelwireless com AT T phonenumber txt att net Boost mobile phonenumber sms myboostmobile com Cricket Wireless phonenumber mms cricketwireless net MetroPCS phonenumber mymetropcs com Project Fi...

Страница 11: ...timed closures are not permitted Action Programming Grid The lower part of the Remote page is a programming grid with inputs shown on the lines and relays in the columns Clicking on a button selects w...

Страница 12: ...cted Up to eight phones can be connected to one RC 4A If a Viking IP phone is on a different subnet than the RC 4A it can be set up to control the RC 4A using the Manual Entries at the bottom of the p...

Страница 13: ...tom of the settings page click on Create Link Select the relay and the action to perform and click on Create Link The link will appear just below the button and can be pasted into the address bar to p...

Страница 14: ...Viking distributor If at any time during the warranty period the product is deemed defective or malfunctions return the product to Viking Electronics Inc 1531 Industrial Street Hudson WI 54016 Custome...

Отзывы: