background image

17

During outbound SIP calls the Panic Button LED can be programmed to light automatically when the called party has
answered or only light after the called party has entered a touch tone “

Factory Setting: 

Automatic

36. Panic Button LED Control

35. Panic Button LED Mode 

The Panic Button LED on the 

PB-3-IP 

can be programmed to one of four different modes. 

Factory Setting: 

Emergency Phone Mode

OFF Mode: 

Useful for silent monitoring applications. In this mode the Panic Button LED will not light during normal

operation. It will only light (blink) if it cannot register with the programmed SIP server or while manually resetting all
network parameters to factory default.

Entry Phone Mode:

The Panic Button LED will remain ON in the idle state, turn off while button is pressed, blink during

dialing, light steady when the call is answered, then turn OFF momentarily when the call is completed. The panic Button
LED will also turn off when the announcement is playing.

Emergency Phone Mode: 

The Panic Button LED will remain OFF in the idle state but will light steady during an

inbound call. During an outbound call, the Panic Button LED will turn on while the button is pressed, blink during dialing,
light steady when the call is connected, then turn off when the call is completed. The Panic Button LED will also turn
off when the announcement is playing.

Emergency Phone Outbound Only: 

The Panic Button LED will remain OFF in the idle state and stays off during an

inbound call. During an outbound call, the Panic Button LED will turn on while the button is pressed, blink during dialing,
light steady when the call is connected, then turn off when the call is completed. The Panic Button LED will also turn
off when the announcement is playing. This mode is useful for silent monitoring on inbound calls.

If enabled and a busy is detected, the 

PB-3-IP

phone will dial the next programmed Emergency Phone number. A

momentary press of the Panic button will dial the first programmed Emergency number.  

Factory Setting: 

Enabled

33. Dial Next Number on Busy 

34. Send ID Number as

32. Dial Next Number on Ring No Answer

If enabled and a ring-no-answer is detected, the 

PB-3-IP 

Phone will dial the next programmed Emergency Phone

number after the programmed amount of rings. A momentary press of the Panic button will dial the first programmed
Emergeny number.  

Factory Setting:

7 (will redial after 7 rings)

The I.D. number can be transmitted as RFC 2833 or as In-Band DTMF.  

Factory Setting:

RFC 2833

Содержание PB-3-IP

Страница 1: ...oss over Regulatory Compliance CE FCC Part 15 and Canada ICES 003 Class A Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Features Applications Specifications VoIP Panic Button with User...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...tocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...rt 10 100 PoE Class 1 4 Watts Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Yellow Network Status LED Lights steady to indicate power and data link Blinks to indicate network...

Страница 5: ...iameter wire exit hole 0 63 UP Mount with this arrow pointing up 0 20 x 0 43 mounting slot 4 0 20 diameter mounting holes Condensation Drain Holes 0 375 Radius Dimensions 5 75 x 3 08 x 1 05 146 mm x 7...

Страница 6: ...the user to program any PB 3 IP connected to that LAN Note PC must be connected to the same LAN as the PB 3 IP IBM compatible personal computer with Windows 7 8 or 10 Adobe Acrobat Reader 8 or higher...

Страница 7: ...flash allowing you to troubleshoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connect...

Страница 8: ...Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for the fields in if D...

Страница 9: ...cting the LAN Cable RJ45 plug Step 2 Press and hold the Panic button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Panic button until you hear 2 beeps approximately 6 seconds Then rel...

Страница 10: ...Microphone Volume 0 9 0 Auto factory set to 5 23 15 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 15 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 15 In...

Страница 11: ...Resolve or Alternate Server 4 Outbound Proxy If your SIP provider requires an outbound proxy IP address enter it in the Outbnd Proxy field If outbound proxy is not required leave this field blank 5 A...

Страница 12: ...sed by emergency personnel to identify the location of the caller and is given out when the receiving party presses a This ID number is transmitted as In Band DTMF or RFC 2833 This can be cleared out...

Страница 13: ...r stereo 2 Sampling rates of 8k 16k or 32kHz are acceptable 3 The WAV file may be stereo or multi channel but only the Left Channel will be loaded 4 When saved wave files will be converted to 8KHz mon...

Страница 14: ...lso affects timing in Doorbell Mode Factory Setting 5 seconds 16 Relay Activation Time 14 Relay Mode Door Strike Mode When programmed for Door Strike Mode the relay will momentarily activate for the p...

Страница 15: ...e Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When background noise decreases the mic gain will automatically increase The Au...

Страница 16: ...le the Two Way Mode mic and speaker audio or Silent Monitor Mode mic only depending on the Speaker Mode selected After the correct Access Code is entered any of the Operation Commands can be used see...

Страница 17: ...rn on while the button is pressed blink during dialing light steady when the call is connected then turn off when the call is completed The Panic Button LED will also turn off when the announcement is...

Страница 18: ...king Technical Support will assist in updating the IP firmware 38 Permanent Alarm Mute Selecting Alarm Tones Disabled will mute all alarm tones indefinitely To re enable alarm tones select Alarm Tones...

Страница 19: ...be entered after answering an outbound call from the PB 3 IP or on an inbound call to the unit when the Inbound Call Mode is set to Auto Answer or Auto Answer Secure If the Access Code has been disabl...

Страница 20: ...tone phone The Panic Button can be programmed to automatically deliver a digital announcement identifying the location of the emergency call and an optional DTMF touch tone code may also be delivered...

Страница 21: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limit...

Отзывы: