31. Ring Cadence
The Ring cadence can be programmed to one of 4 different cadences.
Factory Setting:
Normal Ring
Normal Ring
(single ring, 2 seconds on 4 seconds off) factory setting
Double Ring
(double ring, 1 second on 0.5 seconds off 1 second on 3.5 seconds off)
Short-Short-Long
(triple ring, 0.5 seconds on 0.5 seconds off 0.5 seconds on 0.5 seconds off 1 second on 3 seconds off)
Short-Long-Short
(triple ring, 0.5 seconds on 0.5 seconds off 1 second on 0.5 seconds off 0.5 seconds on 3 seconds off)
The Inbound Call Mode determines how the
PB-3-IP
Phone handles incoming SIP calls. One option is to auto answer
a SIP call for silent monitoring or two way communication. The
PB-3-IP
Phone can also generate a loud ring sound
from the speaker. Alternatively inbound calls can be disabled when using the
PB-3-IP
for Panic Button applications,
and the
PB-3-IP
will only make outbound calls.
Factory Setting:
Auto Answer
Disabled
– Inbound SIP calls are not allowed.
Auto Answer
– Inbound SIP calls are auto answered on the first ring. This can also be used for Silent Monitoring by
changing the Speaker Mode to ‘OFF/Silent Monitor” (See Programming section 20). For more security use the Auto
Answer Secure Mode. When Auto Answer mode is used, the announcement can “be listened to” (or repeated) by dialing
a “
” on an inbound call. If a “#” is dialed during playback, the
PB-3-IP
will stop the announcement and enable the
speaker. If an access code is programmed and someone calls in, the access code can be dialed to monitor audio or
control the relay of the
PB-3-IP
. The
PB-3-IP
will hang up if the access code is not dialed within 10 seconds.
Auto Answer Secure
– In the “Auto Answer - Secure” mode, the phone will automatically answer an incoming call and
output 1 beep but will not go into two-way voice mode. After the beep is heard, you will have 10 seconds to enter the
pre-programmed 1 - 6 digit Access Code (see Programming section 10). When the correct code is entered, 2 beeps
will be heard and the unit will enable the Two-Way Mode (mic and speaker audio) or Silent Monitor Mode (mic only),
depending on the Speaker Mode selected. After the correct Access Code is entered, any of the “Operation Commands”
can be used (see Operation section C), when the Relay Mode is set to Door Strike.
Note:
If the wrong Access Code is
entered or more than 10 seconds have elapsed, the phone will output 3 beeps and disconnect.
Ring:
In the “Ring” mode the speaker phone will not automatically answer an incoming call but will output a loud ring
signal out of the speaker in a factory programmed 2 seconds on, 4 seconds off ring pattern. There are four available
ring cadences. The call can then be answered by momentarily pressing the Panic button.
Ring with AGC:
In the “Ring with AGC” mode the speaker phone will not automatically answer an incoming call but
will output a loud ring signal out of the speaker in a factory programmed 2 seconds on, 4 seconds off ring pattern.
There are four available ring cadences. The phone will automatically increase or decrease the ring volume based on
background ambient noise. The call can then be answered by momentarily pressing the Panic button.
30. Inbound Call Mode
28. Lap Counter
With the lap counter disabled, if the
PB-3-IP
Phone is programmed to dial the next number on ring-no-answer and/or
busy signal, the
PB-3-IP
Phone will continuously call its programmed phone numbers forever until the call is answered.
The lap counter is a programmable counter that determines how many times the
PB-3-IP
Phone will cycle through its
list of up to 5 Emergency phone numbers, before it stops the dialing process and hangs up. When all of the programmed
phone numbers have been dialed, the lap counter is incremented and the dialing process repeats. When the lap counter
has been met, the dialing process stops and the
PB-3-IP
Phone hangs up.
Factory Setting:
Disabled
This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute
up to a maximum of 9 minutes or disabled. With the call length disabled, the
PB-3-IP
Phone must rely on a call ended
signal or other methods of disconnect detection.
Factory Setting:
Disabled
29. Call Length Timeout