background image

16

31. Ring Cadence

The Ring cadence can be programmed to one of 4 different cadences.

Factory Setting:

Normal Ring

Normal Ring 

(single ring, 2 seconds on 4 seconds off) factory setting

Double Ring

(double ring, 1 second on 0.5 seconds off 1 second on 3.5 seconds off)

Short-Short-Long

(triple ring, 0.5 seconds on 0.5 seconds off 0.5 seconds on 0.5 seconds off 1 second on 3 seconds off)

Short-Long-Short

(triple ring, 0.5 seconds on 0.5 seconds off 1 second on 0.5 seconds off 0.5 seconds on 3 seconds off)

The Inbound Call Mode determines how the 

PB-3-IP 

Phone handles incoming SIP calls.  One option is to auto answer

a SIP call for silent monitoring or two way communication. The 

PB-3-IP 

Phone can also generate a loud ring sound

from the speaker. Alternatively inbound calls can be disabled when using the 

PB-3-IP 

for Panic Button applications,

and the 

PB-3-IP 

will only make outbound calls.  

Factory Setting: 

Auto Answer

Disabled

– Inbound SIP calls are not allowed.

Auto Answer

– Inbound SIP calls are auto answered on the first ring. This can also be used for Silent Monitoring by

changing the Speaker Mode to ‘OFF/Silent Monitor” (See Programming section 20). For more security use the Auto
Answer Secure Mode. When Auto Answer mode is used, the announcement can “be listened to” (or repeated) by dialing
a “

” on an inbound call. If a “#” is dialed during playback, the 

PB-3-IP 

will stop the announcement and enable the

speaker. If an access code is programmed and someone calls in, the access code can be dialed to monitor audio or
control the relay of the 

PB-3-IP

.  The 

PB-3-IP

will hang up if the access code is not dialed within 10 seconds.

Auto Answer Secure

– In the “Auto Answer - Secure” mode, the phone will automatically answer an incoming call and

output 1 beep but will not go into two-way voice mode. After the beep is heard, you will have 10 seconds to enter the
pre-programmed 1 - 6 digit Access Code (see Programming section 10). When the correct code is entered, 2 beeps
will be heard and the unit will enable the Two-Way Mode (mic and speaker audio) or Silent Monitor Mode (mic only),
depending on the Speaker Mode selected. After the correct Access Code is entered, any of the “Operation Commands”
can be used (see Operation section C), when the Relay Mode is set to Door Strike. 

Note: 

If the wrong Access Code is

entered or more than 10 seconds have elapsed, the phone will output 3 beeps and disconnect.

Ring:

In the “Ring” mode the speaker phone will not automatically answer an incoming call but will output a loud ring

signal out of the speaker in a factory programmed 2 seconds on, 4 seconds off ring pattern. There are four available
ring cadences. The call can then be answered by momentarily pressing the Panic button. 

Ring with AGC:

In the “Ring with AGC” mode the speaker phone will not automatically answer an incoming call but

will output a loud ring signal out of the speaker in a factory programmed 2 seconds on, 4 seconds off ring pattern.
There are four available ring cadences. The phone will automatically increase or decrease the ring volume based on
background ambient noise. The call can then be answered by momentarily pressing the Panic button.

30. Inbound Call Mode

28. Lap Counter 

With the lap counter disabled, if the 

PB-3-IP 

Phone is programmed to dial the next number on ring-no-answer and/or

busy signal, the 

PB-3-IP 

Phone will continuously call its programmed phone numbers forever until the call is answered.

The lap counter is a programmable counter that determines how many times the 

PB-3-IP 

Phone will cycle through its

list of up to 5 Emergency phone numbers, before it stops the dialing process and hangs up. When all of the programmed
phone numbers have been dialed, the lap counter is incremented and the dialing process repeats. When the lap counter
has been met, the dialing process stops and the 

PB-3-IP 

Phone hangs up.  

Factory Setting: 

Disabled

This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute
up to a maximum of 9 minutes or disabled. With the call length disabled, the 

PB-3-IP 

Phone must rely on a call ended

signal or other methods of disconnect detection.  

Factory Setting:

Disabled

29. Call Length Timeout 

Содержание PB-3-IP

Страница 1: ...oss over Regulatory Compliance CE FCC Part 15 and Canada ICES 003 Class A Connections 1 RJ45 10 100 Base T 3 gel filled butt connectors Features Applications Specifications VoIP Panic Button with User...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...tocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...rt 10 100 PoE Class 1 4 Watts Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Yellow Network Status LED Lights steady to indicate power and data link Blinks to indicate network...

Страница 5: ...iameter wire exit hole 0 63 UP Mount with this arrow pointing up 0 20 x 0 43 mounting slot 4 0 20 diameter mounting holes Condensation Drain Holes 0 375 Radius Dimensions 5 75 x 3 08 x 1 05 146 mm x 7...

Страница 6: ...the user to program any PB 3 IP connected to that LAN Note PC must be connected to the same LAN as the PB 3 IP IBM compatible personal computer with Windows 7 8 or 10 Adobe Acrobat Reader 8 or higher...

Страница 7: ...flash allowing you to troubleshoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connect...

Страница 8: ...Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for the fields in if D...

Страница 9: ...cting the LAN Cable RJ45 plug Step 2 Press and hold the Panic button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Panic button until you hear 2 beeps approximately 6 seconds Then rel...

Страница 10: ...Microphone Volume 0 9 0 Auto factory set to 5 23 15 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 15 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 15 In...

Страница 11: ...Resolve or Alternate Server 4 Outbound Proxy If your SIP provider requires an outbound proxy IP address enter it in the Outbnd Proxy field If outbound proxy is not required leave this field blank 5 A...

Страница 12: ...sed by emergency personnel to identify the location of the caller and is given out when the receiving party presses a This ID number is transmitted as In Band DTMF or RFC 2833 This can be cleared out...

Страница 13: ...r stereo 2 Sampling rates of 8k 16k or 32kHz are acceptable 3 The WAV file may be stereo or multi channel but only the Left Channel will be loaded 4 When saved wave files will be converted to 8KHz mon...

Страница 14: ...lso affects timing in Doorbell Mode Factory Setting 5 seconds 16 Relay Activation Time 14 Relay Mode Door Strike Mode When programmed for Door Strike Mode the relay will momentarily activate for the p...

Страница 15: ...e Cancelling mode With the mic in the Auto mode when background noise increases the mic gain will automatically decrease When background noise decreases the mic gain will automatically increase The Au...

Страница 16: ...le the Two Way Mode mic and speaker audio or Silent Monitor Mode mic only depending on the Speaker Mode selected After the correct Access Code is entered any of the Operation Commands can be used see...

Страница 17: ...rn on while the button is pressed blink during dialing light steady when the call is connected then turn off when the call is completed The Panic Button LED will also turn off when the announcement is...

Страница 18: ...king Technical Support will assist in updating the IP firmware 38 Permanent Alarm Mute Selecting Alarm Tones Disabled will mute all alarm tones indefinitely To re enable alarm tones select Alarm Tones...

Страница 19: ...be entered after answering an outbound call from the PB 3 IP or on an inbound call to the unit when the Inbound Call Mode is set to Auto Answer or Auto Answer Secure If the Access Code has been disabl...

Страница 20: ...tone phone The Panic Button can be programmed to automatically deliver a digital announcement identifying the location of the emergency call and an optional DTMF touch tone code may also be delivered...

Страница 21: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limit...