The Speaker Mode will be set to one of the following two modes. This is selected automatically based on Inbound Call Mode. 

OFF/Silent Monitoring Mode:

  In the “OFF” mode the speaker is disabled on inbound calls. However, the speaker can be 

enabled after communication has been established by entering touch tone command “

9#

”. The speaker will then remain on 

for the duration of the call. 

ON (Factory Setting):

  In the “ON” mode the speaker is enabled during In-bound and Out-bound calls. 

27. Speaker Mode  

When set to “Enabled” the Remote Access Operation Commands to Un-Latch or Latch the relay are enabled. 
When set to “Disable” the Remote Access Operation Commands to Un-Latch or Latch the relay are disabled. Disabling the 
Latch commands can be useful in applications where you want to eliminate the possibility of inadvertently entering a latch 
command leaving a gate open/closed, etc. The relays can still be activated with the “Relay Activation Command” for 
momentary closures.  

Factory Setting:

 Enabled

22. Relay Latch Commands 

The speaker volume can be set from 0 - 9, 0 = lowest volume setting, 9 = highest volume setting. Alternatively the speaker 
can be turned off for silent monitoring (see Speaker Mode section 27).  

Factory Setting:

 3

28. Speaker Volume 

The microphone volume can be set from 1 - 9, 1 = lowest volume setting, 9 = the highest volume setting. Alternatively the 
microphone can be placed in the “Auto” (Automatic Noise Cancelling) mode. With the mic in the Auto mode, when background 
noise increases, the mic gain will automatically decrease. When background noise decreases the mic gain will automatically 
increase. The Auto mode is useful in applications where the background noise level can change drastically such as a gas car 
running vs a diesel truck.  

Factory Setting:

 5 seconds

29. Microphone Volume / Automatic Noise Cancelling Mode 

This feature selects switching time between talk and listen modes (VOX switching time).  The Talk/Listen Delay can be 
programmed from 0.1 - 0.9 seconds.  

Factory Setting:

 0.5 seconds

26. Talk / Listen Delay (VOX)

The In-Band Audio Call Progress Detection can be set to enabled or disabled. In-Band Audio Call Progress detection should 
be enabled in applications where you are making an outbound call through your VoIP phone system and are relying on In-
Band analog audio for ringback or busy detection.  

Factory Setting:

 E

nabled

23. In-Band Audio Call Progress 

The In-Band Audio Detect level (Sensitivity) can be set from 1 - 9, 1 = minimum setting, 9 =  highest setting. Increasing or 
decreasing the sensitivity may be required in applications where you are making an outbound call through your VoIP phone 
system and are relying on In-Band analog audio detection.  

Factory Setting:

 5 

24. In-Band Audio Detect Sensitivity

This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute up to 
a maximum of 9 minutes or disabled. With the call length disabled, the 

K-1270-IP

 

phone must rely on a call ended signal, 

busy signal, Ring No Answer limit, or touch tone “#” command to hang-up.  

Factory Setting:

 3 minutes

 

Note:

 Timer starts after call is connected. If call is not answered (and ring no answer disabled) there is a default 7 minute 

timer.

25. Call Length Time Out 

Содержание K-1270-IP Series

Страница 1: ...single push auto dialing of a tenant s phone number or business extension When the K 1270 IP phone is connected to an apartment or business tenant a built in contact closure may be activated to contr...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...s a signaling communications protocol widely used for controlling multimedia communication sessions such as voice and video calls over Internet Protocol IP networks The protocol defines the messages t...

Страница 4: ...Output Viking Model PRX 3 or LRR 4 See DOD 228 OR 226 Optional Long Range RFID Receiver Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire wit...

Страница 5: ...flush mount unit using the included rough in box or as a surface mount unit using an optional VE 5x10 or VE 5x10 SS The rough in box uses the inner set of four holes on the face plate while the VE 5x1...

Страница 6: ...l Viking model RC 4A Secure Remote Relay Controller see page 6 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network PC Programming IBM compatible personal computer...

Страница 7: ...trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network wi...

Страница 8: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Страница 9: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Страница 10: ...de must be set to Door Strike 22 17 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 17 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit...

Страница 11: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1270 IP Series Phone being programmed When registered to a...

Страница 12: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1270 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Страница 13: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 14: ...lity to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call the K 1...

Страница 15: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Страница 16: ...ng Disabled The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated After the called party enters the correct relay activation command the...

Страница 17: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Страница 18: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1270 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Страница 19: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Страница 20: ...one of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Rela...

Страница 21: ...rogrammed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card within 6 inch...

Страница 22: ...netic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 23: ...backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and scre...

Страница 24: ...age across the network to activate one of the relays on the other unit Two levels of user access permit selected users to have full operational and programming rights while others have operational con...

Страница 25: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: