9.  Entry Code Database

Clicking on the “Entry Code Database” button will open the Entry Code Database screen. 

The Entry Code Database will then download, this can take over a minute. The Entry Code Database will allow you to 
program the Relay Function, Relay 1 or 2, once only (one time use only), Entry Type (Card, Keyless or both), Keyless 
Code, Proximity Card #, Facility Code, Day of week, Time of Day and Tenant Name. Tenant names are stored locally 
on the PC and are not uploaded. When “Card + Keyless” is selected, a valid card must be presented and the keyless 
code entered within 15 seconds.

 

The security code allows the user/installer to program the 

K-1270-IP Series 

Phone. It is recommended that the factory 

set security code be changed. 

Factory Setting:

 845464 

Note:

  The security code must be 6 digits and cannot include a 

Q

 or a 

#

.

11. Security Code 

The Access Code is used for remotely operating the relays (Doorstrike, Mag-Lock, etc) by calling into the unit. This 
code provides basic security and only allows operation of the relays and not the ability to change any of the 
programming parameters. Once entered, any of the “Remote Access Operation Commands” can be used. The code 
can be 1 - 6 digits in length and cannot contain a “

Q

” or “#”.  Simply call the 

K-1270-IP

 phone, the unit will automatically 

answer the line and output one beep. You then enter the programmed 1 - 6 digit access code, 2 beeps should be heard. 
You can now enter any “Remote Access Operation Commands” (see page 21). This code will also enable audio to/from 
the speaker and the caller. The access code can be cleared (by leaving the field blank) if this additional level of security 
is not required.  

Factory Setting:

 123456

 

12. Access Code 

Keyless Entry Code and Proximity Card logging can be set to Log Errors. With Log Errors selected, (factory setting) 
the 

K-1270-IP

 will not only log all valid Keyless Entry Code and Proximity Card entries, but also log any errors, incorrect 

codes, or non-valid card reads. 

Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the 

K-1270-IP

 programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card 

read will immediately open the Event Log screen and display the latest entry.

10. Keyless / Card Logging

Содержание K-1270-IP Series

Страница 1: ...single push auto dialing of a tenant s phone number or business extension When the K 1270 IP phone is connected to an apartment or business tenant a built in contact closure may be activated to contr...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...s a signaling communications protocol widely used for controlling multimedia communication sessions such as voice and video calls over Internet Protocol IP networks The protocol defines the messages t...

Страница 4: ...Output Viking Model PRX 3 or LRR 4 See DOD 228 OR 226 Optional Long Range RFID Receiver Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire wit...

Страница 5: ...flush mount unit using the included rough in box or as a surface mount unit using an optional VE 5x10 or VE 5x10 SS The rough in box uses the inner set of four holes on the face plate while the VE 5x1...

Страница 6: ...l Viking model RC 4A Secure Remote Relay Controller see page 6 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network PC Programming IBM compatible personal computer...

Страница 7: ...trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the network wi...

Страница 8: ...Settings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values fo...

Страница 9: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Страница 10: ...de must be set to Door Strike 22 17 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 17 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit...

Страница 11: ...If Authentication ID is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the K 1270 IP Series Phone being programmed When registered to a...

Страница 12: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1270 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Страница 13: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Страница 14: ...lity to change any of the programming parameters Once entered any of the Remote Access Operation Commands can be used The code can be 1 6 digits in length and cannot contain a Q or Simply call the K 1...

Страница 15: ...ection is set to outbound the 26 bit Wiegand connections become an output and can be connected to the card reader input on the access control system Unprogrammed keyless entry codes dialed by the user...

Страница 16: ...ng Disabled The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated After the called party enters the correct relay activation command the...

Страница 17: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Страница 18: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1270 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Страница 19: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Страница 20: ...one of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Rela...

Страница 21: ...rogrammed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card within 6 inch...

Страница 22: ...netic Lock 120V AC Door near Entry Phone 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Страница 23: ...backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and scre...

Страница 24: ...age across the network to activate one of the relays on the other unit Two levels of user access permit selected users to have full operational and programming rights while others have operational con...

Страница 25: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Отзывы: