7
IMPORTANT SAFETY INFORMATION
!
WARNING! Not Following these instructions may cause severe injury or death.
IMPORTANT INSTALLATION INSTRUCTIONS (Continued)
7. The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation
of the reset control shall not cause the operator to start.
8. A minimum of two (2) WARNING SIGNS shall be installed, in the area of the gate. Each
placard is to be visible by persons located on the side of the gate on which the placard is
installed.
9. For gate operators using non-contact sensors (photoelectric beam or like) in
accordance with section 32.1.1 of the UL standard:
a. See instructions on the placement of non-contact sensors for each type of
application (refer to page 10).
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a
vehicle, trips the sensor while the gate is still moving, and
c. One or more non-contact sensors shall be located where the risk of entrapment or
obstruction exists, such as the perimeter reachable by a moving gate or barrier (refer
to page 10).
d. For UL compliance: Use only Omron: E3K-R10K4-NR-1 // EMX: IRB-RET, IRB-MON //
Miller Edge: RG-K-R, PG-K-R100, PG-K-R50, MIM- 62
For ETL compliance: Use only Seco-Larm E-931-33PRGQ, E-936-S45RRGQ, E-931-
S50RRGQ, E-960-D90GQ // EMX NIR-50-325
10. For a gate operator utilizing a contact sensor (edge sensor or like) in accordance
with section 32 .1.1 of the UL 325 standard:
a. One or more contact sensors shall be located where the risk of entrapment or
obstruction exists, such as a the leading edge, trailing edge, and post mounted both
inside and outside of a vehicular horizontal slide gate (refer to page 10).
b. One or more contact sensors shall be located at the bottom of a vehicular vertical lift
gate.
c. One or more contact sensors shall be located at the pinch point of a vehicular
vertical pivot gate.
d. A hardwired contact sensor shall be located and its wiring arranged so that
the communication between the sensor and the gate operator is not subject to
mechanical damage.
e. A wireless contact sensor such as one that transmits radio frequency (RF) signals
to the gate operator for entrapment protection functions shall be located where the
transmission of the signals are not obstructed or impeded by building structures,
natural landscaping or similar obstructions. A wireless contact sensor shall function
under the intended end-use conditions.
f.
One or more contact sensors shall be located on the inside and outside leading edge
of a swing gate. Additionally, if the bottom edge of a swing gate is greater than 6
inches (152 mm) but less than 16 inches (406 mm) above the ground at any point in
its arc of travel, one or more contact sensors shall be located on the bottom edge.
g. One or more contact sensors shall be located at the bottom edge of a vertical barrier
(arm).
h. For UL compliance: Use only EMX: WEL-200K // Miller Edge: ME110 through ME117,
ME120, ME123, MG020, MGR20, MGS20, RB-G-K10, MIM- 62 // ASO: 25.30, 25.45,
95. 20
www.PerformanceGateOpeners.com | (800) 878-7829 | [email protected]