![Viking E-60-BK-IP Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/viking/e-60-bk-ip/e-60-bk-ip_product-manual_1024527007.webp)
E. Replacement IP Board Kit (Model E-1600-53A-IP)
This is a board (PCB) only kit, no chassis is included. This kit can be used to convert any Viking
E-60
analog phone to
a VoIP version. The kit can also be used to replace a damaged IP board in the field. This kit comes in standard and
EWP version. The optional EWP version features foam rubber gaskets and boots, sealed connections, gel-filled butt
connectors, as well as urethane or thermal plastic potted circuit boards, see
DOD# 859
for more information.
MAC:
18E80FXXXXXX
asdesaxtff
(2) 0.156
diameter
type 2
mounting
holes
0.15 (0.19 EWP)
3.50 (3.58 EWP)
3.20
2.0
(2.04
EWP)
0.63
(0.67
EWP
1.5
2.63
(2.71
EWP)
Gray (N.C.)
Blue (COM)
Yellow (N.O.)
Black
Red
Black
Black
Red**
Red**
White
White
Black
Red
- Black
+ Red
Black
Black
Red**
Red**
White
White
- Black
+ Red
LED
Call Switch
Info Switch
(not used)
Speaker
Mic
Connector and Wires
from Existing Standard
E-60 Analog
Entry Phone
FIGURE 1
Replacement Cable Assembly
(included )
- OR -
Replacement connectors, wires and
butt connectors for use when replacing
E-60-EWP
circuit boards.
Optional 2 Amp Relay
Output Contacts Connector
Connect to doorstrike,
mag lock, gate controller, etc.
3
1 10
1
Step 1.
Cut wires from J1 (10 pin connector) and J2 (2 pin connector).
Step 2.
Remove the two #6 phillips screws fastening the circuit board.
Step 3.
Cut off any stripped wire ends from the replacement cable.
Step 4.
Using the supplied gel-filled butt connectors, connect corresponding wires from replacement cable to the previously cut
wires from the LED, Call switch, Speaker and Microphone. See
FIGURE 1
above for wire color and polarity.
How to Replace Analog E-60 Circuit Boards:
E-1600-53A-IP Board Specifications
Shipping Weight:
.45 kg (1 lb)
Connections:
(1) RJ45 10/100 Base-T, (3)
optional gel-filled butt connectors, (10) addi-
tional gel-filled butt connectors included with
EWP version only.
Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum in-
sulation of 0.082 inches. Cut off stripped wire ends before terminating.
7
** Note:
These two red wires are only used on units with an Info button. When installing on a single button unit, cut off these two red
wires and discard.