![Viking E-60-BK-IP Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/viking/e-60-bk-ip/e-60-bk-ip_product-manual_1024527010.webp)
Quick Programming Features
(after accessing the Touch Tone Programming Mode)
DESCRIPTION
DIGITS
+
MEMORY
LOCATION
First speed dial number
0-32 digits
+
#00
Second speed dial number
0-32 digits
+
#01
Third speed dial number
0-32 digits
+
#02
Fourth speed dial number
0-32 digits
+
#03
Fifth speed dial number
0-32 digits
+
#04
To clear any speed dial number
(no digits)
+
#00 - #04
Talk/Listen Delay (VOX) (0.1 to 0.9 seconds, factory set to 0.5 seconds)
1 digit (1-9)
+
#11
Call Length Time Out (0 to 9 minutes, 0 = disabled, factory set to 3 minutes)
1 digit (0-9)
+
#12
Lap Counter (0 to 9, 0 = disabled, factory set to 0)
1 digit (0-9)
+
#16
Dial Next Number on Ring No Answer
(0 or 1 = disabled, 2 - 9 = number of rings, factory set to 7)
1 digit (0-9)
+
#17
Dial Next Number on Busy (0 or 1, 0 = disabled, 1 = enabled, factory set to 1)
1 digit (0 or 1)
+
#18
Security code (factory set to 845464)
6 digits (0-9)
+
#19
Identification number (1-6 digits, blank = disabled, factory set to 987654)
0-6 digits (0-9)
+
#20
Access Code (1-6 digits, blank = disabled, factory set to 123456)
0-6 digits (0-9)
+
#21
Microphone volume (0-9, 0 = ANC, factory set to 5)
1 digit (0-9)
+
#22
Speaker Volume (0-9, factory set to 5)
1 digit (0-9)
+
#23
Relay Activation Command ( 1 or 2 digits,
QQQQ
=
,
Q
#
Q
# = ##, 0-9 or 00-99, factory set to
) (Relay Mode must be set to 0 = Door Strike)
1 or 2 digits
+
#24
Relay Activation Time (2 digits, 00-99 sec, 00= 0.5 sec, factory set to 05)
2 digits (00-99)
+
#25
Relay Mode (0 = Door Strike, 1 = Outbound Call, 2 = In/Outbound Call, 3 = Doorbell, 4 =
LV-1K
Control, 5 = Ring, 6 = Ring Flash, factory set to 0)
1 digit (0-6)
+
#26
Relay Activation Tone (Buzz) Volume (1 digit 0-3, 0 = off, factory set to 3)
1 digit (0-3)
+
#27
In-Band Audio Detection Sensitivity (1-9, 1 = minimum, 9 = maximum, factory set to 5, power
cycle unit after setting)
1 digit (1-9)
+
#28
In-Band Audio Call Progress Detection (0 or 1, 0 = OFF, 1 = ON, factory set to 0)
1 digit (0 or 1)
+
#29
“Call Connected” LED Control (0 or 1, 0 = Automatic, 1 = Called Party Control /
Q
entered to light
LED, factory set to 0)
1 digit (0 or 1)
+
#30
Speaker Mode
(0, 1 or 2, 0 = OFF/Silent Monitor, 1 = ON, 2 = OFF Until Answered, factory set to 1)
1 digit (0-2)
+
#31
LED Mode (0 to 3, 0 = OFF/Silent Monitor, 1 = Entry Phone, 2 = Emergency Phone,
3 = Emergency Phone outbound only, factory set to 1)
1 digit (0-3)
+
#32
Auto Answer/Loud Ring (0 to 3, 0 = Disabled, 1 = Auto Answer, 2 = Loud Ring,
3 = Loud Ring with AGC, factory set to 1)
1 digit (0-3)
+
#33
DESCRIPTION
ENTER DIGITS
Diagnostic tones (used to check mic and speaker operation)
Q
0
Enable Alternate Switch Action (factory setting)
Q
1
Disable Alternate Switch Action
Q
2
Enable Relay Latching Commands (factory setting)
Q
6
Disable Relay Latching Commands
Q
7
To add a
Q
at any point in the dialing string
To add a # at any point in the dialing string
Q
#
Reset all
Quick Programming Features
to factory default settings
###
10