![Viking Designer DMOR200SS Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/viking/designer-dmor200ss/designer-dmor200ss_service-manual_1024966023.webp)
23
DMOR200SS
TESTPROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Using an ohm-meter, check between the terminals as described in the following table:
MEASURING POINT
INDICATION OF OHM-METER
Between source and source
Open Circuit
Between load and source Short Circuit
Between load and source
Short Circuit
If incorrect readings are obtained, replace the noise filter.
6. Reconnect all leads removed from components during testing.
7. Re-install the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
Q
NOISE FILTER TEST
NOISE FILTER UNIT
NOISE SUPPRESSION COIL
LINE CROSS CAPACITOR
TOR 0.22uF/ AC 250V
LINE BYPASS CAPACITOR
LINE BYPASS CAPACITOR
0.0033uF/ AC
125V
0.0033uF/ AC
125V
LOAD
LOAD
SOURCE
SOURCE
Содержание Designer DMOR200SS
Страница 36: ...43 DMOR200SS NOTES...