![Viking Designer DMOR200SS Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/viking/designer-dmor200ss/designer-dmor200ss_service-manual_1024966002.webp)
2
DMOR200SS
PRECAUTIONS TO BE OBSERVED BEFORE
AND DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave
source, and make repairs as necessary: () interlock operation, (2) proper door closing, (3) seal and sealing
surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of
dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity,
and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and
transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before
the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be performed
on each oven prior to release to the owner.
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave Measure-
ment Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact Viking Service immediately @ -
888-845-464.
If the unit operates with the door open, service person should () tell the user not to operate the oven and
(2) contact VIKING, plus the Department Of Health, Canada and/or the Food and Drug Administration's
Center for Devices and Radiological Health immediately.
Service personnel should inform VIKING of any certified unit found with emissions in excess of 4mW/
cm
2
. The owner of the unit should be instructed not to use the unit until the oven has been brought into
compliance.
NOTICE
In the interest of user-safety the oven should be restored to its original condition and only parts identical
those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high
voltage and current. Contact with the following parts may result in a severe, possibly fatal, electrical shock.
(High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High
Voltage Harness etc..)
Содержание Designer DMOR200SS