manualshive.com logo in svg
background image

Installation

Tuscany Hoods

TVWH360
TVWH480
TVWH660

Содержание TVWH360

Страница 1: ...Installation Tuscany Hoods TVWH360 TVWH480 TVWH660...

Страница 2: ...the hood from the power supply before servicing or cleaning Our hoods are equipped with variable speed control blowers These units will not function with a single speed ventilator All Viking Range ve...

Страница 3: ...y questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service di...

Страница 4: ...cover sold separately 18 H Wall Hoods Description 36 48 66 Duct cover width 35 7 8 91 1 cm 47 7 8 121 6 cm 65 7 8 167 3 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm Number of lights 2...

Страница 5: ...5 Clearance Dimensions 30 min 76 2 cm to 36 max 91 4 cm 36 91 4 cm 18 45 7 cm 12 30 5 cm optional duct cover 66 min 167 6 cm to 72 max 182 9 cm...

Страница 6: ...6 cm 66 W 65 7 8 167 3 cm A B 7 17 8 cm dia duct location 4 5 8 11 7 cm B 36 W 35 7 8 91 1 cm A 36 W 17 15 16 45 6 cm 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 1200 CFM Inter...

Страница 7: ...cm A B 10 25 4 cm dia duct location 5 15 16 15 1 cm A 36 W 17 15 16 45 6 cm 48 W 23 15 16 60 8 cm 66 W 32 15 16 83 7 cm B 36 W 35 7 8 91 1 cm 48 W 47 7 8 121 6 cm 66 W 65 7 8 167 3 cm 900 or 1200 CFM...

Страница 8: ...proper sized duct work and roof or wall cap for the type of blower you are using Recommended hood locations for the most common installations are shown Adjust your measurements for various heights of...

Страница 9: ...Nut driver 5 16 Nut Driper CAUTION Secure vent hood to wall using screws provided Use additional mounting screws and wall anchors if necessary CAUTION If not using a duct cover using screws provided...

Страница 10: ...from ceiling to canopy Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided To install ventillation kit refer to ventillation kit installation instructions...

Страница 11: ...el and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner Model no ____________________________________ Serial no ________________________...

Страница 12: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com F21448D EN 030118...