manualshive.com logo in svg
background image

Proper installation of ducting is extremely
important to ensure maximum performance from
any ventilation product.
• All CFMs are based on tests at 0.1 static

pressure: without applying static pressure, CFM
would be greatly overstated.

• Straight runs and gradual turns are best; for

example, each 90º elbow is equivalent to 5-10
feet (1.52-3.05 cm) of straight run.

• Never use flexible duct; it creates back pressure/air

turbulence and greatly reduces performance.

• Proper performance is dependent on proper

ducting; make sure that a qualified and trained
installer is used.

• Check with a qualified and trained installer or

local codes for makeup air requirement, if any.

• Max. amp rating for hoods includes

recommended ventilator kit rating; all products
must be hard wired direct with 2-wire with ground.

Plan where the duct work will be located. Install
proper-sized duct work, and roof or wall cap for the
type of blower you are using. Recommended hood
locations for the most common installations are
shown. Adjust your measurements for various heights
of ceilings, soffits, cabinets, or ranges/rangetops.

Check Framing

NOTE: Because of the weight of the hood make sure
that the mounting screws are driven into the framing
and not just the drywall. It may be necessary to drill
additional holes in the canopy for proper alignment.

Roof Cap

7” round duct

Duct cover or soffit

300 or 600 CFM

single blower

interior-power

typical ductwork

Hood

Roof cap

10

 ro

un

d d

u

ct

D

u

ct cover or soffit

1200 CFM

single blower

interior power

typical ductwork

Hood

Exterior blower

10” round duct

Duct cover or soffit

900, 1200, or 

1500 CFM

exterior power

typical ductwork

Hood

Duct

Duct cover or soffit

Wall Installation exterior

power typical

ductwork

NOTE:   Wall exhaust must be a minimum of 24” (61.0 cm)
from ground. This may vary depending on local codes
and geographic location.

Hotte

Wall Cap

 

8

Planning Information

Содержание TVWH360

Страница 1: ...Installation Tuscany Hoods TVWH360 TVWH480 TVWH660...

Страница 2: ...the hood from the power supply before servicing or cleaning Our hoods are equipped with variable speed control blowers These units will not function with a single speed ventilator All Viking Range ve...

Страница 3: ...y questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service di...

Страница 4: ...cover sold separately 18 H Wall Hoods Description 36 48 66 Duct cover width 35 7 8 91 1 cm 47 7 8 121 6 cm 65 7 8 167 3 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm Number of lights 2...

Страница 5: ...5 Clearance Dimensions 30 min 76 2 cm to 36 max 91 4 cm 36 91 4 cm 18 45 7 cm 12 30 5 cm optional duct cover 66 min 167 6 cm to 72 max 182 9 cm...

Страница 6: ...6 cm 66 W 65 7 8 167 3 cm A B 7 17 8 cm dia duct location 4 5 8 11 7 cm B 36 W 35 7 8 91 1 cm A 36 W 17 15 16 45 6 cm 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 1200 CFM Inter...

Страница 7: ...cm A B 10 25 4 cm dia duct location 5 15 16 15 1 cm A 36 W 17 15 16 45 6 cm 48 W 23 15 16 60 8 cm 66 W 32 15 16 83 7 cm B 36 W 35 7 8 91 1 cm 48 W 47 7 8 121 6 cm 66 W 65 7 8 167 3 cm 900 or 1200 CFM...

Страница 8: ...proper sized duct work and roof or wall cap for the type of blower you are using Recommended hood locations for the most common installations are shown Adjust your measurements for various heights of...

Страница 9: ...Nut driver 5 16 Nut Driper CAUTION Secure vent hood to wall using screws provided Use additional mounting screws and wall anchors if necessary CAUTION If not using a duct cover using screws provided...

Страница 10: ...from ceiling to canopy Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided To install ventillation kit refer to ventillation kit installation instructions...

Страница 11: ...el and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner Model no ____________________________________ Serial no ________________________...

Страница 12: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com F21448D EN 030118...

Отзывы: