TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Installation work and electrical wiring must be

done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.

2. Sufficient air is needed for proper combustion

and exhausting of gases through the flute
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.

3. When cutting of drilling into wall or ceiling, do

not damage electrical wiring and other hidden
utilities.

4. Ducted fans must always be vented to the outdoors.
5. WARNING!: To reduce risk of fire, use only

metal ductwork

6. CAUTION!: To reduce risk of fire and to

properly exhaust air, be sure to duct air outside.
Do not vent exhaust air into spaces within walls
or ceilings, or into attics, crawl spaces, or
garages.

7. CAUTION!: To Reduce the Risk of Fire and

Electric Shock, Install this rangehood only with
remote blower models manufactured by Viking
Range, model numbers – DEV900/DEV1200,
VEV900/VIL1200 or integral blowers
manufactured by Viking,Range model numbers
– VINV300/600/1200 or DIl1200. NOTE –
Please refer inside for specific canopy/blower
combinations.

WARNING

WARNING

To reduce the risk of fire, electric shock, or injury to
persons, observe the following:

• Use this unit only in the manner intended by the

manufacturer. If you have any questions, contact
the manufacturer.

• Before servicing or cleaning unit, switch power off

at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.

WARNING

TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY 
TO PERSONS

Rangehoods must be installed with
the ventilators that are specified on
their carton indicating suitability with
this model. Other ventilators cannot be substituted.

CAUTION

For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and
vapors.

WARNING

To reduce the risk of injury to persons in the event
of a rangetop grease fire, observe the following.
(Based on “Kitchen Firesafety Tips,” published by
NFPA.)

1. SMOTHER FLAMES with a close fitted lid, cookie

sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames do
not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN. You may be

burned.

3. DO NOT USE WATER, including wet dishcloths or

towels a violent steam explosion will result.

4. Use an extinguisher ONLY if

• You know it is a Class ABC extinguisher, and you

already know how to operate it.

• The fire is small and contained in the area where

it started.

• The fire department is being called.
• You can fight the fire with your back to an exit.

Warnings

CAUTION

This appliance is not to be used by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning the use of
the appliance by a person responsible for their
safety. Children should be supervised to ensure
that they do not play with the appliance.

Содержание TVWH360

Страница 1: ...Installation Tuscany Hoods TVWH360 TVWH480 TVWH660...

Страница 2: ...the hood from the power supply before servicing or cleaning Our hoods are equipped with variable speed control blowers These units will not function with a single speed ventilator All Viking Range ve...

Страница 3: ...y questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service di...

Страница 4: ...cover sold separately 18 H Wall Hoods Description 36 48 66 Duct cover width 35 7 8 91 1 cm 47 7 8 121 6 cm 65 7 8 167 3 cm Duct cover depth 12 30 5 cm Duct cover height 12 30 5 cm Number of lights 2...

Страница 5: ...5 Clearance Dimensions 30 min 76 2 cm to 36 max 91 4 cm 36 91 4 cm 18 45 7 cm 12 30 5 cm optional duct cover 66 min 167 6 cm to 72 max 182 9 cm...

Страница 6: ...6 cm 66 W 65 7 8 167 3 cm A B 7 17 8 cm dia duct location 4 5 8 11 7 cm B 36 W 35 7 8 91 1 cm A 36 W 17 15 16 45 6 cm 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods 1200 CFM Inter...

Страница 7: ...cm A B 10 25 4 cm dia duct location 5 15 16 15 1 cm A 36 W 17 15 16 45 6 cm 48 W 23 15 16 60 8 cm 66 W 32 15 16 83 7 cm B 36 W 35 7 8 91 1 cm 48 W 47 7 8 121 6 cm 66 W 65 7 8 167 3 cm 900 or 1200 CFM...

Страница 8: ...proper sized duct work and roof or wall cap for the type of blower you are using Recommended hood locations for the most common installations are shown Adjust your measurements for various heights of...

Страница 9: ...Nut driver 5 16 Nut Driper CAUTION Secure vent hood to wall using screws provided Use additional mounting screws and wall anchors if necessary CAUTION If not using a duct cover using screws provided...

Страница 10: ...from ceiling to canopy Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided To install ventillation kit refer to ventillation kit installation instructions...

Страница 11: ...el and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner Model no ____________________________________ Serial no ________________________...

Страница 12: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com F21448D EN 030118...

Отзывы: