Installation

The Incogneeto™ can be used with natural stone or “engineered stone” (crushed stone and polymer resin composite). It is not
recommended for use with “solid surfaces” (all polymer resin).

Important Characteristics Of NATURAL Stone

Stone is a natural material with random natural defects in any given piece. Cracking can occur due to these defects alone.  Moreover,
cracks can occur when pre-existing weak points are subjected to additional stresses or forces.
Heat differentials that cause one portion of the stone to try to expand while other portions try to remain fixed, will cause excess stress.
This localized heating can come from a number of sources:

a. Heat lamps above the stone
b. Heat generated by equipment below the stone
c. Heat from hot items placed on top of the stone

In extensive testing, 

NO NATURAL STONE

was found to interfere with the performance of the wireless communications, or absorb

excess heat from the electro-magnetic induction waves associated with its Incogneeto™ and Magneeto™ II equipment.

Design Considerations When Using Incogneeto™with NATURAL STONE

Any temperature gain that occurs inside the cabinet where an Incogneeto™ is mounted contributes to heating the stone. Keeping the
inside of the cabinets as close to room temperature as possible will therefore reduce stress on the stone. Cabinets with poor or
insufficient ventilation will increase the stress on the stone. Tensile strength of natural stone is proportionately linear with thickness: 3/4”
(2.0cm) stone is 1/3rd thinner than 1-1/4” (3.0cm) stone, so that resistance to cracking is also reduced by 1/3. Applications with
prolonged intensive use are better served with 30mm stone above Incogneeto™ units. 1-1/4” (3.0cm) thick natural stone dissipates heat
much better than 3/4” (2.0cm), resulting in lower maximum temperatures. For prolonged intensive use applications, thicker stone is more
durable. The stone is not generally heated by the induction waves, but some heating will occur from radiation back from a hot pan. The
stone around the portion that is heated from radiation provides the mechanical strength “buffer” to help prevent fractures. Allowing as
much stone around the edge of the Incogneeto™ as possible will improve the strength of the whole system.

Best Practices Design Guidelines for Installation Under NATURAL STONE

It is recommended that natural stone over the Incogneeto™ be 1-1/4” (30mm) thick in high use applications. Synthetic or “engineered
stone” at 3/4” (2.cmm) is perfectly acceptable over the Incogneeto™ in all applications. (Note: 3/4” [2.0cm] tops in any material also
require plywood substrate.) It is further recommended that cabinets be built with sufficient ventilation to keep the interior compartment as
close to room temperature as possible. At least 8” of additional stone surface should be allowed from the edge of the Incogneeto™
location to the final edge of any piece of natural stone. This requirement is NOT necessary for use with engineered stone. Extra care
should be taken to not have a mechanical seam in the cabinet support above or close to the Incogneeto™. 

General Guidelines

Note

: With engineered stone, none of these extra guidelines apply, as it is a much more uniform and generally stronger material.

Heat lamps should not be used above any Incogneeto™ units, unless they are interlocked to prevent heating when a pan is not present,
or damage to the disk may occur. Installation is only recommended under three countertop configurations:
1-1/4” (3.0cm) stone, with 1/2” (1.2cm) substrate; or 1-1/4” (3.0cm) stone with 3/4” (2.0cm) plywood strips; or 3/4” (2.0cm) stone with 3/4”
(2.0cm) substrate.

Countertop Preparation

(3.8cm - 4.2cm) 

1-1/2”– 1-5/8”

(3.8cm - 4.2cm) 

1-1/2”– 1-5/8”

(3.8cm - 4.2cm) 

1-1/2”– 1-5/8”

The combined thickness of stone, wood and any air
gap MUST BE WITHIN A RANGE OF 1-1/2” to 1-5/8”
(3.8cm to 4.2cm). Too far away, communications
between the Magneeto II disk and Incogneeto may fail,
and/or insufficient thermal energy will be delivered to
the pan. Too close and too much energy could be
delivered resulting in damage the electronics in the
Magneeto II disk. Metals should NOT be used in any
part of the countertop construction directly above an
installed Incogneeto unit, although trace metals in the
stone or engineered stone ARE permissible. Metals in
cabinet construction may heat and / or interfere with
communication between the Magneeto II and
Incogneeto.

Содержание Incogneeto

Страница 1: ...Use and Care Installation Guide Incogneeto Induction Warmer ...

Страница 2: ...Electrical Requirements ____________________________________________________________________5 Countertop Preparation______________________________________________________________________6 Unit Installation ____________________________________________________________________________7 Using Your Induction Warmer ____________________________________________________________________8 Care and Maintenan...

Страница 3: ...and others All safety messages will be preceded by the safety alert symbol and the word DANGER WARNING or CAUTION These words mean Hazards or unsafe practices which WILL result in severe personal injury or death DANGER Hazards or unsafe practices which COULD result in severe personal injury or death Hazards or unsafe practices which COULD result in minor personal injury or property damage All safe...

Страница 4: ...re operating read grounding instructions and Electrical Installation Requirements on page 2 of this booklet Do not use an extension cord Do not overcook food or leave appliance unattended while in use In the unlikely event of a grease fire smother flame by covering pan with a tight fitting lid cookie sheet or flat tray DO NOT USE WATER When the fire is under control turn off appliance and unplug f...

Страница 5: ...5 Installation Dimensions A 17 1 2 4 5 cm B 4 1 2 1 8 cm C 2 7 8 7 4 cm D 2 1 4 5 7 cm E 3 1 4 8 3 cm F 1 3 16 3 0 cm G 2 1 2 6 3 cm H 3 13 16 9 7 cm J 1 2 5 cm Dimensions ...

Страница 6: ...appliance Such use may result in fire electrical shock or other personal injury WARNING ELECTRICAL GROUNDING INSTRUCTIONS This induction warmer must be electrically grounded in accordance with local codes or in the absence of codes with the National Electrical Code ANSI NFPA 70 latest edition FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED Mounting MagneetoTM II Control Panel Use incl...

Страница 7: ...echanical strength buffer to help prevent fractures Allowing as much stone around the edge of the Incogneeto as possible will improve the strength of the whole system Best Practices Design Guidelines for Installation Under NATURAL STONE It is recommended that natural stone over the Incogneeto be 1 1 4 30mm thick in high use applications Synthetic or engineered stone at 3 4 2 cmm is perfectly accep...

Страница 8: ...l the unit with the Antenna side label on the same side you want the MagneetoTM II communication tab to located Natural Stone or Engineered Stone Counter top Natural Stone or Engineered Stone Counter top Mounting frame or collar Look for Antenna Side other sides not marked Incogneeto Unit Holes for spring studs 1 1 4 3 0 cm stone with 1 2 1 2 cm substrate or 3 4 2 0 cm stone with 3 4 2 0 cm substr...

Страница 9: ...ing the servers and not the guests Servers can see that the system is working and guests are not distracted by the lights Mount units on Collar with Antenna Side against the wall MagneetoTM II wireless communicator must be above the Antenna Side MagneetoTM II can be used with the LED Indicator in the 3 o clock or 6 o clock position The 3 o clock position avoids the lights shining directly at seate...

Страница 10: ...n LED next to the power button will illuminate Place a Magneeto II trivet on the countertop and position it over top of the unit until the LED begins flashing and the SmarTag LED illuminates Place an induction compatible cookware bakeware on the top of the trivet To ensure contact wiith the temperature sensor on the MagneetoTM II trivet the cookware bakeware must have a flat bottom The Pan Detect ...

Страница 11: ...g the unit off completes the selection Note if a button is not pressed for more than five minutes the unit will power off keeping the previously set temperature scale Timer Operation To enable disable the timer feature see Setting the Timer below If the timer is enabled the timer will start counting when a pan is placed on the unit and the Heating or At Temp LED will turn on The timer will count u...

Страница 12: ...ting with the unit off hold the Down Arrow while pressing the Power Button Release the buttons when the display comes on Use the Up and Down Arrows to toggle through the options until t Int is shown on the display Press the Lock Button to select the interval option Press the Up and Down Arrows to increase or decrease the amount of time desired for the timer interval When the desired time displayed...

Страница 13: ...rmers and series 650 watt wireless communicator induction units DO NOT use the Magneeto II with any other induction appliance as it may be damaged Pan bottom size should be between 7 and 12 17 8 30 5 cm in diameter The dish pan bottom must be flat and in contact with the temperature sensor dome or overheating will result Some upward bowing of the Magneeto II when hot and a cookware bakeware is rem...

Страница 14: ...ats Pan is not induction efficient Pan bottom may not be flat enough Pan not centered Pan diameter is less than 7 or more than 12 Use induction efficient pan Use flatter pan Center pan Use an induction efficient pan that is between 7 12 17 8 30 5cm in diameter In the event of a possible malfunction your induction warmer will display an error code on the alphanumeric display Some models will beep a...

Страница 15: ...ication plate mounted on the top left side of the oven door opening under the control panel Record the information indicated below You will need it if service is ever required The model and serial number for your induction warmer can be found by looking under the unit Model No ____________________________________Serial No ______________________________________ Date of Purchase ____________________...

Страница 16: ...as specified under the limited warranty Under the terms of this warranty service must be performed by a factory authorized Viking Range LLC service agent or representative Service will be provided during normal business hours and labor performed at overtime or premium rates shall not be covered by this warranty Owner shall be responsible for proper installation providing reasonable and necessary m...

Отзывы: