7
Male
Male
coupler
coupler
Installer supplied
flexible gas line
with 1/2” female
adapter or GHS12
Installer supplied
shut-off valve must
be easily accessible
7/8” male
flare adapter
Regulator
Assembly
3/8”
3/8”
male
male
flare
flare
dapter
dapter
1/2”
NPT
from
Manifold
Natural Fixed Piping Connection
Connection:
Standard Residential 1/2” ID gas service line - 1/2” NPT male with 7/8” flare adapter.
Operating Pressure:
4.0” W.C.P. Nat.
Supply Pressure:
6” to 10” W.C.P. Nat. If in excess of 10” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on
type and size of run and how deep to bury the lines. If the gas line is too small, the unit will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 7/8” (2.2 cm) female flare adaptor
to the 7/8” (2.2 cm) male flare adaptor on the regulator assembly. Ensure that the regulator arrow points in the direction of the
gas flow towards the unit and away from the supply. Connect the regulator assembly to the grill unit . All connectors need to
comply with ANSI Z21.75/ CSA 6.27. When using semi-ridged tubing, aluminum or aluminum alloy tubing is not permitted.
DO NOT forget to place the installer supplied gas valve in an accessible location.
NOTE: If using a GSH12 flexible hose, remove the 1/2” flare adapter and attach hose to the the 1/2” (1.3 cm) male flare on
the regulator assembly.