1.  At least one ventilation opening shall be provided on the

exposed exterior side of the enclosure located within 5
inches (127 mm) of the top of the enclosure and
unobstructed. The opening(s) shall have a total free area
of not less than 1 in

2

/lb (14.2 cm

2

/kg) of stored fuel

capacity.

2.  At least one ventilation opening shall be provided on

the exposed, exterior side of the enclosure 1 inch (25.4
mm) or less from the floor level and shall have a total
free area of not less than 1/2 in

2

/lb (7.1 cm

2

/kg) of

stored fuel capacity. The upper edge shall be no more
than 5 inches (127 mm) above the floor level.

3.  Every opening shall have a minimum dimension so as to

permit the entrance of a 1/8 inch (3.2 mm) rod.

Ventilation for Built-in Installation

Vents

1.00 inch maximum

5.00 inch
maximum

All vents no more than 5.00 inches
above the floor of the installation.

5.00 inch
maximum

Not more than 5.00 
inches from inside
bottom of countertop.

Bottom Vent not
more than 1.00 inch 
from inside floor of 
installation.

Vents located
on sidewall

Gas Connection

Verify the type of gas supply to be used, either natural or LP/Propane and make sure the marking on the wok/cooker
rating plate agrees with that of the supply.  Never connect an unregulated gas line to the appliance.  An installer
supplier gas shut-off valve must be installed in an easily accessible location.  All installer supplied parts must conform
to local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1-latest edition.  Installation
in Canada must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-
B149.2, Propane Installation Code and/or local codes. All connectors need to comply with ANSI Z21.75/ CSA 6.27.
When using semi-ridged tubing, aluminum or aluminum alloy tubing is not permitted.

All pipe sealants must be an approved type and resistant to the actions of LP gases.  Never use pipe sealant on flare
fittings.  All gas connections should be made by a competent technician and in accordance with local codes and/or
ordinances.  In the absence of local codes, the installation must comply with the National Fuel Gas Code ANSIZ223.1-
latest edition.

The wok/cooker and its individual shut-off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The wok/cooker must be isolated from
the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that system
at test pressures equal to or less than 1/2 PSIG (3.5 kPa). Built-in installations must be plumbed using a fixed/hard line if
the unit is going to be operated at a distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI
Z21.24/CSA 6.10

Содержание CVGWTO5241

Страница 1: ...Use Installation Built In Gas Outdoor Wok Cooker VGWTO5241 CVGWTO5241 ...

Страница 2: ...ak is not a do it yourself procedure Some leaks can only be found with the burner control in the on position and this must be done by a qualified technician 7 The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tub...

Страница 3: ...he utensil scorching the outside of the utensil and making cleanup harder 10 The flame of the surface burner should be adjusted to just cover the bottom of the pan or pot Excessive burner setting may cause scorching of adjacent countertop surfaces as well as the outside of the utensil This is based on safety considerations 11 Use dry pot holders Moist or damp potholders on hot surfaces may result ...

Страница 4: ...s Requirements Natural standard residential 1 2 1 3 cm ID gas service line LP Propane standard residential 1 2 1 3 cm ID gas service line or equipped with high capacity hose regulator assembly for connection to standard 20 lb LP Propane gas cylinder with Type 1 QCC 1 connection Unit must be ordered Natural or LP Propane Not Field Convertible 12 V 8 AA batteries Electrical Requirements Burner Ratin...

Страница 5: ...ruction where an LP Propane tank is going to be used there MUST be some type of support braces cut out etc to prevent tank from moving within the installation The support must also allow the LP Propane tank to withstand a horizontal tipping force equal to the weight of the tank without tipping over The tank can not tip over or deflect more than 1 00 inch when a 38 lb horizontal force is applied to...

Страница 6: ...as shut off valve must be installed in an easily accessible location All installer supplied parts must conform to local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 latest edition Installation in Canada must be in accordance with the current CAN CGA B149 1 Natural Gas Installation Code or CAN CGA B149 2 Propane Installation Code and or local codes All connectors n...

Страница 7: ...to check on type and size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 7 8 2 2 cm female flare adaptor to the 7 8 2 2 cm male flare adaptor on the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the u...

Страница 8: ...nd size of run and how deep to bury the lines If the gas line is too small the unit will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 3 8 female flare adaptor to the 3 8 male flare adaptor to the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Con...

Страница 9: ...or to the LP Propane tank Open the tank valve and check the connection between the regulator and the Type 1 QCC 1 fitting for leaks with a soapy water solution If bubbles appear tighten the connection Repeat until all leaks have been stopped ALWAYS CHECK FOR LEAKS AFTER EVERY LP PROPANE TANK CHANGE Any joint sealant used must be an approved type and be resistive to the actions of LP Propane gas LP...

Страница 10: ...duce the air and to prevent a noisy flame that lifts off the burner 5 Turn the surface burners off 6 Tighten the air shutter screws 7 Replace the grate support and grate A B 3 4 1 91 cm Air Shutter Orifice Initial Ignition of Burners All appliances are tested before leaving the factory Field adjustments may be necessary for proper mixture of gas and air for proper operation When the unit is connec...

Страница 11: ...ers will ignite at any on position with the automatic reignition system If the flame goes out for any reason the burners will automatically reignite if the gas is still flowing When gas is permitted to flow to the burners the electric igniters start sparking On all surface igniters you should hear a clicking sound If you do not turn off the control and check that the unit is plugged in and that th...

Страница 12: ... the front right side interior of the unit Loosen the head screws to remove the lid which is connected to 8 AA batteries After replacing the batteries reattach the lid with the screws Replace the pan burner bowls and grates Note Please be environmentally conscious dispose of old batteries properly Replacing Batttery Pack ...

Страница 13: ...e graphics from the control panel Use hot soapy water and a soft clean cloth Control Knobs MAKE SURE THE CONTROL KNOBS POINT TO THE OFF POSITION BEFORE REMOVING Pull the knobs straight off Wash in detergent and warm water Do not soak knobs Dry completely and replace by pushing firmly onto stem Stainless Steel Parts All stainless steel parts should be wiped regularly with hot soapy water at the end...

Страница 14: ...ervice is ever required The serial number and model number for your wok cooker is located on the left rear side of the burner box Model Number ___________________________________________Serial Number_____________________________________ Date of Purchase __________________________________________Date Installed _____________________________________ Dealer s Name _____________________________________...

Страница 15: ...owner of the product during the term of the warranty and applies to products purchased and located in the United States and Canada Products must be purchased in the country where service is requested If the product or one of its component parts contains a defect or malfunction during the full warranty period after a reasonable number of attempts by the warrantor to remedy the defect or malfunction...

Страница 16: ... 101515 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking website at vikingrange com in the US or brigade ca in Canada ...

Отзывы: