PLANNING

ELECTRICAL SPECIFICATIONS

Model VDVI600 - Internal Flex: 

/V!NV

Models VDVE900, VDVE1200 - Exterior 

/V!NVA5L

TAKE MEASUREMENTS

Due  to  its  flexible  design,  this  downdraft  system  can  be  used  to 

exhaust airborne contaminants when cooking with a variety of gas or 

electric cooking appliances - 

including cooktops, rangetops, slide-in 

ranges and free-standing ranges.

It can be mounted in island, peninsula, or conventional wall location. The 

blower (purchase separately) and electrical panel can be mounted to the 

downdraft unit, inside the cabinet, or in a convenient remote location.
This unit can be easily installed following these basic steps:

V

 Cut out the countertop opening.

V

 Mount the unit in the cabinet.

V

 Install the blower and electrical panel.

V

 Connect the ductwork and electrical.

V

 Mount the trim/door.

V

 Install the cooking appliance.

Note: the high level of air flow of this appliance may effect the gas 

flame on some types of gas cooktops. This is NORMAL and will cause 

no harm, but can be corrected by lowering the speed of the blower.

PLAN THE DUCTWORK

1.  Refer to the cooktop installation instructions for dimensions of 

cooktop, countertop cut-out, and cabinet requirements. However, 

it  is  recommended  that  oversized  cabinets  be  used  for  easier 

installation.

2.  Cooktop depth can vary greatly from one to another. This may 

cause the fit of these two appliances to be rather tight.

Pay special attention to the areas of potential interference highlighted 

above. A countertop with (A) a raised lip and/or (B) a backsplash may not 

allow enough flat countertop for a proper installation. Note that 2-3/4" of 

flat countertop is required behind cooktop and that 2-1/2" is necessary 

between the back edge of the cooktop and the inside of cabinet back.

A

B

C

D

E

F

HOUSING

1.  The downdraft blower system is designed for use with 

8" round ductwork using a flex blower or 10" Round 

ductwork using a remote blower. (Purchase blowers 

separately.) Six (6) different discharge connections are 

available - with side-to-side adjustment for accurate 

alignment of ductwork:
A  =  8" Round, Left Discharge out of Flex Blower
B  =  8" Round, Right Discharge out of Flex Blower
C  =  8" Round, Down Discharge out of Flex Blower

(Electrical Box to be mounted remotely)

D  =   2" x 19

¼

", Left Discharge out of Housing 

to Remote Blower or Flex Blower in remote 

location.  Use 2" x 19

¼

" to 8" round transition, 

2" x 19

¼

" to 10" round transition, or 2" x 19

¼

ductwork as appropriate.

E  =   2" x 19

¼

", Right Discharge out of Housing 

to Remote Blower or Flex Blower in remote 

location.  Use 2" x 19

¼

" to 8" round transition, 

2" x 19

¼

" to 10" round transition, or 2" x 19

¼

ductwork as appropriate.

F  =   2" x 19

¼

", Rear Discharge out of Housing 

to Remote Blower or Flex Blower in remote 

location. Use 2" x 19

¼

" to 8" round transition, 

2" x 19

¼

" to 10" round transition, or 2" x 19

¼

ductwork as appropriate.

2.  For best performance: Choose the ducting option which 

allows the shortest length of ductwork and a minimum 

number  of  elbows  and  transitions.  Check  location  of 

floor joists, wall studs, electrical wiring or plumbing for 

possible interference.

CONTENTS

These parts are included with your downdraft housing:

1 - Parts Bag containing:

2 - 2-in. Support Legs

2 - 4-in. Support Legs2 - Screws, 1/4-20 x .50 Hex Head

2 - Screws, 1/4-20 x .50 Hex Head

2 - Screws, #8-18 x .375 Phillipst

8 - Wood Screws, #10 x .50 Phillips Round Head

1 - Trim Kit

1 - Electrical Panel

2 - Support Brackets

2-3/4"

2-1/2"

FLEX

BLOWER 

*

*

  Remote blowers use 8" or 10" round remote discharge 

plate instead of flex blower.

Содержание CVDD5300

Страница 1: ...USE INSTALLATION GUIDE 5 Series Rear Downdraft Ventilators ...

Страница 2: ...ktop 10 Children should not be left alone or unattended in the area where this appliance is in use 11 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking ...

Страница 3: ...ired behind cooktop and that 2 1 2 is necessary between the back edge of the cooktop and the inside of cabinet back A B C D E F HOUSING 1 The downdraft blower system is designed for use with 8 round ductwork using a flex blower or 10 Round ductwork using a remote blower Purchase blowers separately Six 6 different discharge connections are available with side to side adjustment for accurate alignme...

Страница 4: ... Tighten the hex nuts to secure blower and panels in place LOWER CHANNEL COVER PLATE COVER PLATES included with blower FLEX BLOWER FRONT PANEL If blower discharge is down electrical panel must be relocated See Step 6 PLAN CABINET CUTOUTS CAUTION BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK check for interference with floor joists wall studs electrical wiring or plumbing Use the dimensions in the ab...

Страница 5: ...ex nuts to secure the plates in place LOWER CHANNEL 8 OR 10 ROUND REMOTE DISCHARGE PLATE Purchase Separatly FRONT PANEL All Installations 5 Slide UPPER SUPPORT BRACKETS into SLIDE CHANNEL at top left and right of unit Attach LONG OR SHORT SUPPORT LEGS depending upon cabinet height to bottom sides of unit with HEX SCREWS provided Do not tighten hex screws completely at this time UPPER SUPPORT BRACK...

Страница 6: ...ere ELECTRICAL PANEL needs to be mounted in a remote location only 6 Remove 4 8 32 HEX NUTS and ELECTRICAL PANEL 5 ft extension cables purchase separately may be needed to mount electrical panel in a remote location Do not use more that 2 extension cables Installations ducting through left right or rear only Requires purchase of 1 7 8 x 19 to 8 or 10 round transition and 1 7 8 x 19 rectangular duc...

Страница 7: ...BINET 1 Remove cooktop 2 Set housing into cabinet countertop opening as far back as possible and make sure it is level 3 Extend SUPPORT LEGS and attach to bottom of cabinet with 2 SCREWS through each leg Tighten HEX SCREWS If cabinet bottom is removed Use blocks as spacers between floor and support legs SUPPORT LEG 2 10 X 500 WOOD SCREWS HEX SCREW 4 Extend UPPER SUPPORT BRACKETS and attached to si...

Страница 8: ...a qualified person s in accordance with all applicable codes and standards Installations using FLEX BLOWER only Installations using REMOTE BLOWER only 4 Run 2 wire plus ground power cable from the exterior or in line blower to wiring box on adaptor plate Remove WIRING BOX COVER 5 Connect blower wires to power cable from exterior or in line blower Black to black white to white and green to ground s...

Страница 9: ...t is necessary to ensure that there is no interference when air vent is raised and lowered There should be a gap of 1 32 1 16 between the back of the cooktop and the front of the downdraft cover MAKE UP AIR DAMPER OPTIONAL Connects to 2 CONTACTS on WIRING BOX Compatible with G6MD and G8MDdamper MAKE UP AIR DAMPER CONTACTS WIRING BOX FINISH TRIM SCREW COUNTERTOP CHIMNEY DOWNDRAFT HOUSING Available ...

Страница 10: ...for 2 or more seconds Indicator will turn off 4 Speed Fan Speed Control 2 Level Task Light 30 Hour Filter Clean Reminder Up Down Button Up Down Button To raise lower chimney touch up down button Any feature that is active will shut off when chimney is retracting All functions will return to their previous settings when chimney is raised Heat Sentry Whentheoperatingtemperatureistoohigh thefanspeedw...

Страница 11: ...l up and out Use a mild detergent DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS Replace front panel and filters before using downdraft SERVICE INFORMATION Only authorized replacement parts may be used in performing service on the appliance All servicing should be referred to a qualified technician Contact Viking Range LLC 1 888 845 4641 for the nearest service parts distributor in ...

Страница 12: ...malfunction the owner is entitled to either a refund or replacement of the product or its component part or parts Replacement of a component part includes its free installation except as specified under the limited warranty Under the terms of this warranty service must be performed by a factory authorized Viking Range LLC service agent or representative Service will be provided during normal busin...