7
D. Replacement IP Board Kit (Model E-1600-53A-IP)
This is a board (PCB) only kit, no chassis is included. This kit can be used to convert any Viking
E-10A
or
E-30
analog
phone to a VoIP version. The kit can also be used to replace a damaged IP board in the field. This kit comes in standard
and EWP version. The optional EWP version features foam rubber gaskets and boots, sealed connections, gel-filled
butt connectors, as well as urethane or thermal plastic potted circuit boards, see
DOD# 859
for more information.
MAC:
18E80FXXXXXX
asdesaxtff
(2) 0.156
diameter
type 2
mounting
holes
0.15 (0.19 EWP)
3.50 (3.58 EWP)
3.20
2.0
(2.04
EWP)
0.63
(0.67
EWP
1.5
2.63
(2.71
EWP)
Gray (N.C.)
Blue (COM)
Yellow (N.O.)
Black
Red
Black
Black
White
White
Black
Red
- Black
+ Red
Black
Black
Red**
Red**
White
White
- Black
+ Red
LED
Call Switch
Info Switch
(not used)
Speaker
Mic
Connector and Wires
from Existing Standard
E-30 Analog Entry Phone
FIGURE 1
Replacement Cable Assembly (included )
- OR -
Replacement connectors, wires and butt
connectors for use when replacing
E-10A,
E-10A-EWP
or
E-30
analog circuit boards.
Optional 2 Amp Relay
Output Contacts Connector
Connect to doorstrike,
mag lock, gate controller, etc.
3
1 10
1
Step 1.
Cut wires from J1 (10 pin connector) and J2 (2 pin connector).
Step 2.
Remove the two #6 phillips screws fastening the circuit board.
Step 3.
Cut off any stripped wire ends from the replacement cable.
Step 4.
Using the supplied gel-filled butt connectors, connect corresponding wires from replacement cable to the previously cut
wires from the LED, Call switch, Speaker and Microphone. See
FIGURE 1
above for wire color and polarity.
How to Replace Analog E-10A, E-10A-EWP or E-30 Circuit Boards:
E-1600-53A-IP Board Specifications
Shipping Weight:
.45 kg (1 lb)
Connections:
(1) RJ45 10/100 Base-T, (3)
optional gel-filled butt connectors, (10) addi-
tional gel-filled butt connectors included with
EWP version only.
Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a
maximum insulation of 0.082 inches. Cut off stripped wire ends before terminating.
** Note:
These two red wires are only used on units with an Info button. When
installing on a single button unit, cut off these two red wires and discard.