background image

C.  E-20-IP / E-20-IP-EWP

The 

E-20-IP

and 

E-20-IP-EWP

are designed to be surface mounted to a single gang box (not included), a standard 4”

x 4” electrical junction box (not included), or directly to a wall or flat sided post.  

Caution:

For rough surfaces (ie: brick,

stucco, etc.) additional caulking may be required.

UP

Call

VIKING

©

3.40"

1.55"

3.40"

2.35"

3.30"

Front view of the

E-20-IP/E-20-IP-EWP

Back Panel of the

E-20-IP/E-20-IP-EWP

Side view of the

E-20-IP/E-20-IP-EWP

To open the speaker box, remove the 
two separate screws from the cover.

Mount back panel to a wall, a single 
gang box or a 4”x4” junction box with 
the arrow pointing up. 

Note:

 

For 

outdoor applications apply a bead of 
caulk between back panel and wall.

Attach the cover to the 
base with the two included 
screws as shown.

6

B    .  E-32-IP / E-32-IP-EWP

-OR-

3.65"
Wide

Min.

2.84"
Tall Min.

*2.25"

Deep

Min.

CONNE

CTED

Call

VIKING

©

"Old Work" Double 

Gang Rough-In Box 

(Allied Molded 9312 box 

shown, not included)

(4) Optional Dry Wall 

Screws (not included)

(2) Junction Box to Double Gang 

Adapter Plates and (4) T-10 Torx 

Flat Head Screws (included)

Front View of Optional

VE-5x5 (not included)

2.25”

Condensation

Drain Hole 

5.14”

5.22”

3.25”

Rear View of

VE-5x5 (not included)

(2) 0.2 x 0.43 slots for 
single gang box

(4) 0.2 x 0.43 slots for 
double gang box

(1) 0.74"

diameter

3.0” 3.3”

3.0”

(4) 0.38” diameter

(for gooseneck 

pedestal mounting)

Optional VE-5x5 Surface Mount Box with black satin 

powder paint finish, not included (DOD# 424). Optional 

VE-LIGHT kit can be used to illuminate the faceplate 

when used with a VE-5x5 (DOD# 428).

WARNING: Do NOT use a wet location box.

Model E-32-IP shown 

in an optional VE-5x5 

Surface Mount Box 

mounted to a 

VE-GNP Gooseneck 

Pedestal

Other pedestal 

options available, 

see DOD# 424

The optional VE-5x5 Surface Mount Box (above) is 
designed to be surface mounted to a single gang 
box, double gang box or VE-GNP Gooseneck 
Pedestal (shown right). For more information on 
the VE-5x5 and VE-GNP, see DOD# 424.

5.0”

Typical

Peel paper liner and adhere gasket 
to back of panel, centering over 
mounting holes. Caution:  
For rough 
surfaces (ie: brick, stucco, etc.) 
additional caulking may be required.

Laser Etched Graphics

Push to Call Button

(4) T-10 Torx stainless steel, 
flat head, security screws 
and drive bit (included)

Optional VE-5x5 

(not included, see 

specifications below)

The 

E-32-IP 

is designed to be flush mounted to a standard double gang electrical box (minimum dimensions of: 3.65”W x 2.84”H x

2.25”D) or surface mounted using an optional Viking model

VE-5x5

.  

* CAUTION:

Excessive wire length and/or using a rough-in box

with inadequate depth can apply force to the circuit board causing physical damage.

Dimensions: 

Overall: 127mm x 127mm x 57mm (5” x 5” x 2.25”)

E-32-IP Faceplate:

14 gauge 316 stainless steel with #4 brushed finish

Shipping Weight: 

1.0 kg (2.12 lbs) 

Blue LED: 

Call connected LED lights steady to help locate the button in low light, flashes during dialing, then lights steady when an-

swered.

Содержание E-10-IP

Страница 1: ...vailable DOD 232 Optional SL 2 or BLK 4 EWP strobe light kit available DOD 242 653 Power PoE class 1 4 watts Dimensions See Installation and Specifications Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Compliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross ove...

Страница 2: ...rvice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Express CUCME X X Freeswitch X Grandstream X Interactive Intelligence X X iptel org X Kamailio X X MetaSwitch X X NEC X OfficeSIP X OpenSIPS X Panasonic with SIP Extension Card X Samsung Communications Man...

Страница 3: ...rt Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or device that fulfills requests from a client This could involve the server sending a particular file requested by the client Session Initiation Protocol SIP Is a signaling communications protocol...

Страница 4: ... Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Yellow Network Status LED Lights steady to indicate power and data link Blinks to indicate network activity Green Unit Status LED Rear PCB View of E 10 20 30 32 IP Entry Phone Red Red White White Power typically not required for gate controllers Doorstrike Magnetic Lock 120V AC Connect to Optional Doorstrike Mag Lock Gate Con...

Страница 5: ... included 5 0 Typical 2 0 2 x 0 43 slots for single gang box 4 0 2 x 0 43 slots for double gang box 1 0 74 diameter 3 0 3 3 3 0 2 1 Wall Stud Front View of Plastic Rough In Box included Wire knock out 2 Standard flat head dry wall sheet rock screws not included VIKING Call 4 0 38 diameter for gooseneck pedestal mounting Peel paper liner and adhere gasket to back of panel centering over mounting ho...

Страница 6: ... 5x5 Surface Mount Box with black satin powder paint finish not included DOD 424 Optional VE LIGHT kit can be used to illuminate the faceplate when used with a VE 5x5 DOD 428 WARNING Do NOT use a wet location box Model E 32 IP shown in an optional VE 5x5 Surface Mount Box mounted to a VE GNP Gooseneck Pedestal Other pedestal options available see DOD 424 The optional VE 5x5 Surface Mount Box above...

Страница 7: ... replacing E 10A E 10A EWP or E 30 analog circuit boards Optional 2 Amp Relay Output Contacts Connector Connect to doorstrike mag lock gate controller etc 3 1 10 1 Step 1 Cut wires from J1 10 pin connector and J2 2 pin connector Step 2 Remove the two 6 phillips screws fastening the circuit board Step 3 Cut off any stripped wire ends from the replacement cable Step 4 Using the supplied gel filled b...

Страница 8: ...nstallation 16MB of free physical RAM Typical Installation on SIP Based VoIP Phone System Extends range of cable keeps 1 Gbps network speed for other equipment on network SIP VoIP PBX or PC with SIP Server Software 100m 328 ft max Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking E 30 IP Entry Phone Note A PoE extender can be used for an additional 100 meters per extend...

Страница 9: ...cating a SIP registration failure failure to receive an echo reply from pinged gateway or Ethernet connection failure You can manually disable the beeps by pressing and holding the Call button for 5 seconds 2 beeps will then be heard or by clicking the Mute Alarm Until Next Failure tab in the Viking VoIP programming software The LED will continue to flash allowing you to trouble shoot the failure ...

Страница 10: ...cess programming as shown in Programming section A Step 2 Enter 123456 19 Step 3 Hang up B Security Code 19 The security code allows the user installer to program the E 10 20 30 32 IP phone The factory set security code is 845464 V I K I N G It is recommended that the factory set security code be changed Note The security code must be 6 digits and cannot include a Q or a Example To store 123456 as...

Страница 11: ... or 2 digits 24 Relay Activation Time 2 digits 00 99 sec 00 0 5 sec factory set to 05 2 digits 00 99 25 Relay Mode 0 Door Strike 1 Outbound Call 2 In Outbound Call 3 Doorbell 4 LV 1K Control factory set to 0 1 digit 0 4 26 Relay Activation Tone Buzz Volume 1 digit 0 3 0 off factory set to 3 1 digit 0 3 27 In Band Audio Detection Sensitivity 1 9 1 min 9 max factory set to 5 power cycle unit after s...

Страница 12: ...tion number 00 04 To clear a speed dial location simply enter the memory location 00 04 alone The E 10 20 30 32 IP phone is factory set with no speed dial number programmed To Program Enter Q QQ Q 0 1 2 9 0 1 2 9 B Speed Dial Programming Examples This feature selects switching time between talk and listen modes VOX switching time Use chart at the right Note The factory default is 5 seconds 2 Talk ...

Страница 13: ...abled and a busy is detected the E 10 20 30 32 IP phone will dial the next pro grammed speed dial number and continue to cycle through the numbers until a call is completed Notes This feature is enabled in the factory default setting If the busy signal is in terrupted with a promotional message contact your central office to have it removed 6 Dial Next Number on Busy 18 Touch Tone Dial on Busy 1 D...

Страница 14: ...Emergency Entry phone This mode is useful for turning on IR flood lights for VoIP phones with cameras etc 3 Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call from the Emergency Entry phone This mode is useful for activating a door chime etc When activating door chimes a 0 5 1 second relay a...

Страница 15: ...tate blink during dialing light steady when the call is connected then turn OFF when the call is completed On in bound calls the LED will remain off This is useful for silent monitoring on inbound calls 19 LED Mode 32 The Speaker Mode can be set to one of the following three modes 0 OFF Silent Monitoring Mode In the OFF mode the speaker is disabled at all times However the speaker can be enabled a...

Страница 16: ...scription Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate the relay Latch Relay Q1 Latch continuously activate the relay Disconnect Disconnects or forces the emergency phone to hang up Send ID and Play Message Q Send I D number if programmed and plays the announcement Note Latching commands must be enabled Q6 in programm...

Страница 17: ...mmunications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with SS are stainless steel version Note The use of magnets to mount the VE...

Страница 18: ...LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any time during the warranty period the product is deemed defective or malfunctions return the product to Viking Electronics Inc 1531 Industrial Street Hudson WI 54016 Cust...

Отзывы: