The microphone volume can be set from 1 to 9 (1 = lowest volume setting, 9 = the highest, factory set to 5) by entering the single
digit then the memory location
#22
. Alternatively the microphone can be placed in the “ANC” Automatic Noise Cancelling mode by
,entering
0#22
in programming. With the mic in the ANC mode, when background noise increases, the mic gain will automatically
decrease. When background noise decreases the mic gain will automatically increase. The ANC mode is useful in applications where
the background noise level can change drastically such as a gas car running vs a diesel truck.
9. Mic Volume/Automatic Noise Cancelling Mode (#22)
The speaker volume can be set from 0 to 9 (0 = lowest volume setting, 9 = the highest, factory set to 5) by entering the single digit
then the memory location
#23
. Alternatively the speaker can be turned off for silent monitoring by entering
0#31
(see Speaker Mode
section 19).
10. Speaker Volume (#23)
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being called must
enter on their phone in order to actuate the relay (door strike/mag-lock/gate controller, etc). The code can contain the numbers 0 - 9,
00 - 99, ## or
(factory default). The code must not match the first 1 or 2 digits of the security code. To program the code to “##”
you must enter
Q
#
Q
# #24
in programming. To program the code to “
” you must enter
QQQQ
#24
in programming. To disable this
feature enter #24 without any preceding digits. The code must be entered while the remote phone is communicating with the Emer-
gency/Entry phone. The Emergency/ Entry phone determines which direction the touch tone is coming from and only responds to
touch tones from the called phone.
11. Relay Activation Command (#24)
The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct touch tone command
is entered. This two digit number can range from 01 to 99 seconds, or enter 00 for 0.5 seconds. The factory setting is 5 seconds.
12. Relay Activation Time (#25)
The 2 amp relay contacts can be programmed to one of five different modes by entering
0,1,2,3 or 4 #26
in programming.
0 = Doorstrike Mode.
When programmed for Doorstrike Mode the relay will momentarily activate for the preprogrammed relay activation time after
detecting the correct relay activation command (one or two digit touch tone) from the called party.
1 = Outbound Call Mode.
When programmed for Outbound Call Mode the relay will activate continuously for the duration of any outbound call from
the Emergency/Entry phone. This mode is useful for activating strobe lights for Emergency VoIP phones.
2 = Inbound/Outbound Call Mode.
When programmed for Inbound/Outbound Call Mode the relay will activate continuously for the duration of any
inbound or outbound call to or from the Emergency/Entry phone. This mode is useful for turning on IR flood lights, for VoIP phones with cameras, etc.
3 = Doorbell Mode.
When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time
on any outbound call from the Emergency/Entry phone. This mode is useful for activating a door chime, etc. When activating door chimes, a 0.5 - 1
second relay activation time is recommended.
4 = LV-1K Control Mode.
When programmed for
LV-1K
Control Mode the relay will activate continuously while the Emergency/Entry phone is powered
and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, activating
LV-1K
’s flashing LED and
audible beep signals.
5 = Loud Ring Mode.
When programmed for Loud Ring Mode the relay will continuously activate while the ringing extension is called. This mode is
useful for activating a Viking model
SL-2
strobe light, etc.
6 = Loud Ring Flash Mode.
When programmed for Loud Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off cadence while
the ringing extension is called. This mode is useful for activating a Viking
LPL-1
Remote Visual Indicator, etc.
13. Relay Mode (#26)
The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated. After the called
party enters the correct relay activation command, the called party will hear 2 short confirmation beeps and the entry phone will
output a buzzing sound (relay activation tone) while the door strike relay is activated.The tone (buzz) length will match the relay ac-
tivation time up to a maximum of 5 seconds. The tone (buzz) can be programmed to three different volume settings 1 = Low, 2=
Medium, 3 = High in memory location #27. The tone can also be turned off/disabled by entering 0#27.
14. Relay Activation Tone (Buzz) Volume (#27)
The In-Band Audio Detection Sensitivity can be set from 1 to 9 (1 = minimum setting, 9 = the highest, factory set to 5) by entering the
single digit then the memory location #28. Increasing or decreasing the sensitivity may be required in applications where you are
making an outbound call through your VoIP phone system and are relying on In-Band analog audio detection of the distant party an-
swering to turn on the call connected LED and/or play the location ID message on Emergency VoIP phones.
IMPORTANT:
Power
cycling the unit is required after touch tone programming this feature.
15. In-Band Audio Detection Sensitivity (#28)
The In-Band Audio Call Progress Detection can be set to 0 or 1 (0 = OFF, 1 = ON, factory set to 0) by entering the single digit then
the memory location
#29
. In-Band Audio Call Progress detection should be turned ON in applications where you are making an out-
bound call through your VoIP phone system and are relying on In-Band analog audio detection of the distant party answering to turn
on the call connected LED and/or play the location ID message on Emergency VoIP phones.
16. In-Band Audio Call Progress Detection (#29)