![Viessmann VITOFLEX 300-RF Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/viessmann/vitoflex-300-rf/vitoflex-300-rf_technical-manual_1017310046.webp)
1490
a
g
f
e
> 200
246
h
d
c
b
C
D
585
287
410
A
B
A
Agitator axis
B
Screw conveyor axis
C
Rotational direction
D
Agitator centre
Sizing of the horizontal discharge AH with agitator and discharge screw conveyor
a
Min. length of protective panel for fuel store walls
b
Sealed channel
c
Open conveyor channel downstream of agitator centre
d
Open conveyor channel upstream of agitator centre, max 2.8 m
e
Wall clearance to centre
f
Discharge circle from 3.9 to 6.1 m subject to situation of fuel store
g
Effective scope 0.8 to 0.95 x f
h
Max. discharge screw conveyor length 10 m
Note
Sizing is influenced by several factors:
■ Fuel
■ Installation position
■ Compression, etc.
Sizing is determined individually for each system by Viessmann.
Fuel discharge
(cont.)