Rated voltage:
230 V ~
Rated frequency:
50 Hz
Rated current :
6.0 A~
Safety class:
I
Protection:
IP X 4 D to
EN 60529
Permissible ambient temperatures
&
during operation:
0 to +40 °C
&
during storage
and transport:
-20 to +65 °C
Electronic tempera-
ture limiter setting:
82 °C (fixed)
Temperature limiter
setting:
100 °C (fixed)
Line fuse (mains):
max. 16 A
Power consumption
&
Circulation pump:
max. 115 W
&
Burner:
max. 40 W
&
Control unit:
max. 10 W
Gas fired boiler, category II
2ELL3P
Rated output range T
V
/T
R
50/30 °C
kW
4.2 to 13
Rated load range
kW
3.9 to 16.7
Connection values
*
1
Relative to the max. load
with:
with H
uB
Natural gas E
9.45 kWh/m
3
34.02 MJ/m
3
m
3
/h
1.77
Natural gas LL
8.13 kWh/m
3
29.25 MJ/m
3
m
3
/h
2.05
LPG
12.79 kWh/kg
46.04 MJ/kg
m
3
/h
1.31
Product ID
_
-0085 BO
0338
Product characteristics (to EnEV [Germany])
Rated output range
kW
4.2 to 13
Efficiency
η
at
&
100% of rated output
%
96.3
&
30% of rated output
%
107.5
Standby loss
q
B,70
*
2
%
1.5
Power consumption
*
2
at
&
100% of rated output
W
170
&
30% of rated output
W
47
Specification
122
Specification
5692
569
GB
*1
The supply values are only for reference (e.g. in the gas contract application) or to esti-
mate the supplementary volumetric settings. Because of factory settings, the gas pres-
sure must not be altered from these values. Reference: 15°C, 1013 mbar.
*2
Max. limit to EnEV [Germany]
Содержание Vitodens 300
Страница 107: ...A1 Main PCB A2 Power supply unit Connection and wiring diagrams external connections 107 Designs 5692 569 GB...
Страница 111: ...Parts lists cont 111 Parts lists 5692 569 GB...
Страница 112: ...Parts lists cont 112 Parts lists 5692 569 GB...
Страница 113: ...Parts lists cont 113 Parts lists 5692 569 GB...
Страница 114: ...Parts lists cont 114 Parts lists 5692 569 GB...
Страница 115: ...Parts lists cont 115 Parts lists 5692 569 GB...
Страница 127: ...127 5692 569 GB...