Mode
Rate
Output
Input
KW
Btu/h
Net
Gross
Central Heating
Max
24.7
84,300
25.7
87,700
28.5
97,100
Min
8.0
27,300
8.4
28,660
9.3
31,800
Domestic Hot Water
Max
27.4
93,550
29.5
100,650
32.74
111,700
Min
8.0
27,300
8.4
28,660
9.3
31,800
2.1.1 Thermal Performance Details
2.1.2 General Performance Details
The Vitodens 200 is certified to comply with the requirements of EN 483 and EN 625 for use in
GB and IE (Great Britain and Ireland) using gas category 2H (G20 with a governed gas supply at
20 mbar (8 in.wg) inlet pressure) or 3P (G31 with a supply pressure of 37mb(14.5in wg)).
The appliance classification is either C13 or C33 depending upon whether a horizontal or vertical
flue terminal is used.
1 General Information
2 Technical Specifications
1.2 Certification Details
2.1 Performance Data
(Combi only)
4
Boiler Model
Maximum gas rate (after 10mins operation i.e. hot) (DHW)
Domestic hot water flow rate
Design domestic hot water performance (specific rate)
Domestic hot water temperature range
Maximum mains water inlet pressure
Minimum mains water inlet pressure for operation
Minimum mains water inlet pressure for max output
Combi
3.1m_/h (110 ft_/h)
4-14l/min (0.88 – 3.1 gpm)
13.1l/min
38 – 57°C
10 bar (145psi)
1.0 bar (14.5psi)
2.0 bar (29psi)
System
2.7m3/h (96ft3/h)
-
-
-
-
-
-
Содержание VITODENS 200 WB2A
Страница 8: ...2 6 Hydraulic Circuit Figure 2 B Hydraulic Circuit 2 Technical Specifications 8 ...
Страница 23: ...Figure 4 B Full Wall template 4 Installation Procedure 23 ...
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......