Coding
40
Coding Level 2
Accessing coding level 2
Note:
H
All codes are displayed as plain text.
H
Codes that are irrelevant due to the system equipment level or the setting of
other codes will not be displayed.
1.
Press
“
w
“ +
“
r
r
r
rw
“
simultaneously for approx. 2 sec.
2.
Press
“
”
to confirm.
3.
Press
“
⊕
/
“ for the required
coding address, the address flashes.
4.
Press
“
”.
to confirm.
5. “
⊕
/
“ for the selected value.
6. “
”.
to confirm. The display
briefly shows ”accepted”, and the
address flashes again.
7. “
⊕
/
“ to select other addresses.
8.
Press
“
w
“ +
“
r
r
r
rw
“
simultaneously for approx. 1 sec.
Coding level 2 is terminated.
The coding addresses are grouped according to the following function
areas. The respective function area is shown on the display.
The areas are scanned in the following sequence by pressing
“
⊕
/
“
.
Function area
Coding addresses
System design
Boiler/Burner
DHW
General
Heating circuit without mix. valve, A1
Heating circuit with mix. valve, M2
00
06 to 54
56 to 73
76 to 9F
A0 to Fb
A0 to Fb
Heating systems with one heating circuit without mixing valve
*1
and one heating
circuit with mixing valve
*2
:
Initially, the possible coding addresses ”A0” to ”Fb” for the heating
circuit without a mixing valve are scanned; then the coding addresses for the
heating circuit with mixing valve are scanned.
*1
May also be referred to as “heating circuit without mixer A1”
.
*2
May also be referred to as “heating circuit with mixer M2”.
5
4
4
3
2
0
7
v
1
.5