Initial Start-up and Service
14
Steps
(continued)
8. Convert fuel type to liquid propane gas
I
nitial start-up
1.
Set adjusting screw
A
at the gas
valve to “2” (using a hex key,
2.5 mm).
2.
Switch ON/OFF switch “
8
” to ON.
3.
Call up coding level 2.(see page 40)
4.
In coding address “11” select
value “9”. The green LED flashes.
5.
In coding address “82” select value
“1” (operation with liquid propane
gas).
6.
Go back to coding address “11”
and select any value (except “9”).
7.
Terminate coding level 2 and open
gas shut-off valve.
8.
Apply supplied fuel conversion
labels.
The Vitodens 200-W, WB2B boiler
comes factory adjusted for operation
with natural gas. Coding address
“82” is set to “0” (operation with
natural gas) in the factory default
setting.
Note:
The system automatically terminates
the parameter change after approx.
25 min., if setting the parameters is
not concluded via coding address 11.
9. Convert to high altitude
I
nitial start-up
In the factory default setting, the boiler is equipped to operate in altitudes of up
to 5,000 ft. / 1,500 m. For operation in higher altitudes, the existing coding card
must be replaced with a high altitude coding card. See table below or the
Viessmann Price List for order information.
1.
Pull out the existing coding card,
cut and remove it from the cable
tie. Insert the high altitude coding
card into the boiler control board.
2.
Install cover. Factory Installed
Boiler Model (base serial #)
0-5,000 ft. /
0-1,500 m
5,000-10,000 ft. /
1,500 - 3,000 m
WB2B 80 (7424193....)
(NG and LPG)
783
3390
*
1
7428965
WB2B 105 (7424194....)
(NG and LPG)
7833391
*
1
7428966
WB2B 80 (7374868....)
(NG Only)
7832 269
*
1
or
7833 231
*
1
7425 958
or
7424 907
WB2B 105 (7374869....)
(NG Only)
7832 270
*
1
or
7833 233
*
1
7425 959
or
7424 910
*
1
Factory Installed
5
4
4
3
2
0
7
v
1
.5
1
2
A
Coding
card
number
2.
Fig. 6
1.
Содержание VITODENS 200-W WB2B 105
Страница 77: ...77 5443 207 v1 5...
Страница 78: ...78 5443 207 v1 5...
Страница 79: ...79 5443 207 v1 5...