36
Plug
sYA
Terminals
Function
Explanation
211.3
r
1.
Instantaneous heating wa-
ter heater switching,
stage 1
Connection values
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
211.4
Connection values
■ Output: 130 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
■ Circulation pump for cyl-
inder heating
or
M
r
■ 3-way diverter valve for
"Central heating/DHW
heating"
211.5
AC
3-way diverter valves for
heating water buffer cylin-
der bypass in the case of
the active cooling function
Connection values
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect 3-way diverter valves parallel to
each other.
Plug
sYS
Terminals
Function
Explanation
212.2
A1
Heating circuit pump for
heating circuit without mixer
A1/HC1
■ If a heating water buffer cylinder is in-
stalled, this pump will be installed in ad-
dition to the secondary pump.
■ Connect temperature limiter to restrict
the maximum temperature for under-
floor heating systems (if installed) in
series: See the following chapter.
Connection values:
■ Output: 100 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
212.3
DHW circulation pump
Connection values:
■ Output: 50 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Installation sequence
Electrical connections, heat pump control unit
(cont.)
5516 436 GB
Содержание VITOCAL 300-A
Страница 5: ...5 Certificates Declaration of conformity 116 Keyword index 117 Index Index cont 5516 436 GB ...
Страница 79: ...79 8x Troubleshooting Repairs cont 5516 436 GB Service ...
Страница 94: ...94 0011 0010 0009 0008 0004 0005 0006 0007 0001 0003 0002 Parts lists Additional components cont 5516 436 GB ...
Страница 96: ...96 0007 0007 0007 0004 0005 0004 0003 0003 0003 0003 0006 0002 0001 Parts lists Air module cont 5516 436 GB ...
Страница 122: ...122 5516 436 GB ...
Страница 123: ...123 5516 436 GB ...