107
Internal hydraulics
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Heat pump for drying a build-
ing"
7300
0
"Time program for screed dry-
ing"
7303
0
"Flow temperature for external
demand"
730C
500 (
≙
50 °C)
"Enable 3-way diverter valve
heating/DHW"
730D
0
"Operating mode secondary
pump"
7340
0
"Starting time high efficiency
circulation pump"
7365
5 s
Heating water buffer cylinder
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Enable buffer cylinder/low
loss header"
7200
0
"Temp in operating status
fixed value for buffer cyl"
7202
500 (
≙
50 °C)
"Hysteresis temperature heat-
ing buffer cylinder"
7203
50 (
≙
5 K)
"Max. temperature buffer cyl-
inder"
7204
600 (
≙
60 °C)
"Temp. limit op. status fixed
value for buffer cylinder"
7208
500 (
≙
50 °C)
Commissioning/service reports
Control parameters report
(cont.)
5516 436 GB